Translation model for anterior segment tomographic data to corneal spherical aberration derived from a Monte-Carlo simulation based on raytracing

被引:0
|
作者
Langenbucher, Achim [1 ]
Szentmary, Nora [2 ,3 ]
Cayless, Alan [4 ]
Munninghoff, Lena [5 ]
Wortmann, Rosalie [5 ]
Wendelstein, Jascha [1 ,6 ]
Hoffmann, Peter [5 ]
机构
[1] Saarland Univ, Dept Expt Ophthalmol, Homburg, Germany
[2] Saarland Univ, Dr Rolf M Schwiete Ctr Limbal Stem Cell & Aniridi, Homburg, Germany
[3] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
[4] Open Univ, Sch Phys Sci, Milton Keynes, Bucks, England
[5] Augen & Laserklin Castrop Rauxel, Castrop Rauxel, Germany
[6] Johannes Kepler Univ Linz, Med Fac, Linz, Austria
关键词
cataract surgery; cornea asphericity; linear mixed-effects model; Monte-Carlo simulation; raytracing; spherical aberration; INTRAOCULAR-LENS; LIGHT REFLEX; IOL;
D O I
10.1111/aos.15125
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Intraocular lenses with a negative aspherical design for correction of corneal spherical aberration (SA) have gained popularity in recent decades. In most cases, a 'one size fits all' concept is followed, where all eyes receive lenses with the same SA correction. The purpose of this study is to develop a strategy based on raytracing using anterior segment tomography data to extract corneal SA and to provide simple multivariable linear models for prediction of corneal SA. Methods The analysis was based on a large dataset of 8737 measurements of 8737 eyes from 1 clinical centre, using the Casia2 anterior segment tomographer. An optical model based on: corneal front and back surface radius Ra and Rp, asphericities Qa and Qp, corneal thickness CCT, anterior chamber depth ACD, and pupil centre position (X-Y position: Pup(X) and Pup(Y)), was defined for each measurement. Corneal SA was derived using a 6-mm aperture perpendicular to the incident ray and centred on the chief ray, and linear prediction models were derived for SA using biometric data. Cross-validation was used for model performance evaluation. Results Using raytracing, the wavefront error within an aperture (6-mm diameter centred on the intersection of the chief ray with the cornea) was calculated and corneal SA was extracted. After identifying the relevant effect sizes (Ra, Qa, Rp Qp, ACD, Pup(X) and Pup(Y)) using stepwise linear regression, linear mixed-effects models (model 1: all effect sizes, model 2: Ra, Qa, Rp and Qp, model 3: Ra and Qa) were set up on the training data in terms of a Monte-Carlo simulation. On the test data (training data), model 1 with a mean absolute/root-mean-squared prediction error of 0.0095/0.0130 (0.0095/0.0127) performed similarly to model 2 with 0.0097/0.0131 (0.0096/0.0127), and both outperformed model3 with 0.0152/0.0197 (0.0148/0.0190). Conclusion Based on the Casia2 anterior segment tomographer, corneal SA could be derived using shape data (curvature and asphericities) of both corneal surfaces (model 2). This information could easily be used for selection of the appropriate negative aspherical lens design in cataract surgery.
引用
收藏
页码:E1665 / E1674
页数:10
相关论文
共 50 条
  • [1] Translation model for CW chord to angle Alpha derived from a Monte-Carlo simulation based on raytracing
    Langenbucher, Achim
    Szentmary, Nora
    Cayless, Alan
    Weisensee, Johannes
    Wendelstein, Jascha
    Hoffmann, Peter
    PLOS ONE, 2022, 17 (05):
  • [2] Monte-Carlo simulation for calculating phakic supplementary lenses based on a thick and thin lens model using anterior segment OCT data
    Achim Langenbucher
    Alan Cayless
    Kitti Kormanyos
    Jascha Wendelstein
    Peter Hoffmann
    Nóra Szentmáry
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1553 - 1565
  • [3] Monte-Carlo simulation for calculating phakic supplementary lenses based on a thick and thin lens model using anterior segment OCT data
    Langenbucher, Achim
    Cayless, Alan
    Kormanyos, Kitti
    Wendelstein, Jascha
    Hoffmann, Peter
    Szentmary, Nora
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (05) : 1553 - 1565
  • [4] Back-calculation of keratometer index based on OCT data and raytracing - a Monte Carlo simulation
    Langenbucher, Achim
    Szentmary, Nora
    Weisensee, Johannes
    Cayless, Alan
    Menapace, Rupert
    Hoffmann, Peter
    ACTA OPHTHALMOLOGICA, 2021, 99 (08) : 843 - 849
  • [5] SEISMIC DISCRIMINANTS OF STRATIGRAPHY DERIVED FROM MONTE-CARLO SIMULATION OF SEDIMENTARY FORMATIONS
    KHATTRI, K
    SINVHAL, A
    AWASTHI, AK
    GEOPHYSICS, 1977, 42 (07) : 1514 - 1514
  • [6] SEISMIC DISCRIMINANTS OF STRATIGRAPHY DERIVED FROM MONTE-CARLO SIMULATION OF SEDIMENTARY FORMATIONS
    KHATTRI, K
    SINVHAL, A
    AWASTHI, AK
    GEOPHYSICAL PROSPECTING, 1979, 27 (01) : 168 - 195
  • [7] Impact of missing genotype data on Monte-Carlo simulation based haplotype analysis
    Becker, T
    Knapp, M
    HUMAN HEREDITY, 2005, 59 (04) : 185 - 189
  • [8] PHYSICALLY REALISTIC MONTE-CARLO SIMULATION OF SOURCE, COLLIMATOR AND TOMOGRAPHIC DATA ACQUISITION FOR EMISSION COMPUTED-TOMOGRAPHY
    YANCH, JC
    DOBRZENIECKI, AB
    RAMANATHAN, C
    BEHRMAN, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04): : 853 - 870
  • [9] MONTE-CARLO SIMULATION IN SPECT - COMPLETE 3D-MODELING OF SOURCE, COLLIMATOR AND TOMOGRAPHIC DATA ACQUISITION
    YANCH, JC
    DOBRZENIECKI, AB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (02) : 198 - 203
  • [10] A Novel Monte-Carlo Simulation-Based Model for Malware Detection (eRBCM)
    Alrammal, Muath
    Naveed, Munir
    Tsaramirsis, Georgios
    ELECTRONICS, 2021, 10 (22)