A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws

被引:164
作者
Wu, Zi-xiang [1 ]
Gong, Fu-tai [2 ]
Liu, Li [3 ]
Ma, Zhen-sheng [1 ]
Zhang, Yang [1 ]
Zhao, Xiong [1 ]
Yang, Min [1 ]
Lei, Wei [1 ]
Sang, Hong-xun [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Inst Orthoped, Xian 710032, Shaanxi Provinc, Peoples R China
[2] Xian Hosp Tradit Chinese Med, Dept Orthoped, Xian 710001, Shaanxi Provinc, Peoples R China
[3] Baoji Cent Hosp, Dept Orthoped, Baoji 721000, Shaanxi Provinc, Peoples R China
关键词
Osteoporosis; Pedicle screws; Spine; Screw loosening; Clinical study; FIXATION; AUGMENTATION; RESTORATION;
D O I
10.1007/s00402-011-1439-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The aim of this study is to compare the rate of screw loosening and clinical outcomes of expandable pedicle screws (EPS) with those of conventional pedicle screws (CPS) in patients treated for spinal stenosis (SS) combined with osteoporosis. Methods One hundred and fifty-seven consecutive patients with SS received either EPS fixation (n = 80) or CPS fixation (n = 77) to obtain lumbosacral stabilization. Patients were observed for a minimum of 24 months. Outcome measures included screw loosening, fusion rate, Japanese Orthopaedic Association (JOA) scores and Oswestry disability index (ODI) scoring system, and complications. Results In the EPS group, 20 screws became loose (4.1%) in 6 patients (7.5%), and two screws (0.4%) had broken. In the CPS group, 48 screws became loose (12.9%) in 15 patients (19.5%), but no screws were broken. The fusion rate in the EPS group (92.5%) was significantly higher than that of the CPS group (80.5%). The rate of screw loosening in the EPS group (4.1%) was significantly lower than that of the CPS group (12.9%). Six EPS (1.8%) screws were removed. In the EPS group, two screws had broken but without neural complications. Twelve months after surgeries, JOA and ODI scores in the EPS group were significantly improved. There were four cases of dural tears, which healed after corresponding treatment. Conclusions EPS can decrease the risk of screw loosening and achieve better fixation strength and clinical results in osteoporotic lumbar spine fusion.
引用
收藏
页码:471 / 476
页数:6
相关论文
共 50 条
[31]   Biomechanical comparison of pedicle screw augmented with different volumes of polymethylmethacrylate in osteoporotic and severely osteoporotic cadaveric lumbar vertebrae: an experimental study [J].
Liu, Da ;
Zhang, Bo ;
Xie, Qing-yun ;
Kang, Xia ;
Zhou, Jiang-jun ;
Wang, Cai-ru ;
Lei, Wei ;
Zheng, Wei .
SPINE JOURNAL, 2016, 16 (09) :1124-1132
[32]   Double pedicle screw instrumentation in the osteoporotic spine - A biomechanical feasibility study [J].
Jiang, Liang ;
Arlet, Vincent ;
Beckman, Lorne ;
Steffen, Thomas .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06) :430-435
[33]   Early clinical results with cortically based pedicle screw trajectory for fusion of the degenerative lumbar spine [J].
Glennie, R. Andrew ;
Dea, Nicolas ;
Kwon, Brian K. ;
Street, John T. .
JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (06) :972-975
[34]   Reduction in Radiation (Fluoroscopy) While Maintaining Safe Placement of Pedicle Screws During Lumbar Spine Fusion [J].
Chaput, Christopher D. ;
George, Keri ;
Samdani, Amer F. ;
Williams, John I. ;
Gaughan, John ;
Betz, Randal R. .
SPINE, 2012, 37 (21) :E1305-E1309
[35]   Posterior instrumentation for osteoporotic fractures in the thoracic or lumbar spine: Cement-augmented pedicle screws vs hybrid constructs [J].
Chou, Po-Hsin ;
Lin, Hsi-Hsien ;
Yao, Yu-Cheng ;
Wang, Shih-Tien ;
Chang, Ming-Chau ;
Liu, Chien-Lin .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (04) :431-439
[36]   Biomechanical study of injectable hollow pedicle screws for PMMA augmentation in severely osteoporotic lumbar vertebrae: effect of PMMA distribution and volume on screw stability [J].
Liu, Da ;
Sheng, Jun ;
Wu, Hong-hua ;
Kang, Xia ;
Xie, Qing-yun ;
Luo, Yang ;
Zhou, Jiang-jun ;
Zheng, Wei .
JOURNAL OF NEUROSURGERY-SPINE, 2018, 29 (06) :639-646
[37]   Comparison of the Pull-Out Strength between a Novel Micro-Dynamic Pedicle Screw and a Traditional Pedicle Screw in Lumbar Spine [J].
Qian, Lei ;
Chen, Weidong ;
Li, Peng ;
Qu, Dongbin ;
Liang, Wenjie ;
Zheng, Minghui ;
Ouyang, Jun .
ORTHOPAEDIC SURGERY, 2020, 12 (04) :1285-1292
[38]   Comparative analysis of the safety and efficacy of fenestrated pedicle screw with cement and conventional pedicle screw with cement in the treatment of osteoporotic vertebral fractures: A meta-analysis [J].
Cao, Li ;
Xu, Hong-Jie ;
Yu, Yi-Kang ;
Tang, Huan-Huan ;
Fang, Bo-Hao ;
Chen, Ke .
CHINESE JOURNAL OF TRAUMATOLOGY, 2025, 28 (02) :101-112
[39]   Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery [J].
Zhao, He ;
Wang, Yan-jun ;
Wang, Rui-guo ;
Liu, Da ;
Duan, Ya-qing ;
Liu, Yang-jin ;
Zeng, Yu-hong ;
Zhao, Qin-peng ;
Zhang, Zheng-ping .
CLINICAL INTERVENTIONS IN AGING, 2023, 18 :485-493
[40]   Pedicle Screw Fixation in Single-Level, Double-Level, or Multilevel Posterior Lumbar Fusion for Osteoporotic Spine: A Retrospective Study with a Minimum 2-Year Follow [J].
Guo, Hui-zhi ;
Tang, Yong-chao ;
Guo, Dan-qing ;
Ma, Yan-huai ;
Yuan, Kai ;
Li, Yong-xian ;
Peng, Jian-cheng ;
Li, Jing-lan ;
Liang, De ;
Zhang, Shun-cong .
WORLD NEUROSURGERY, 2020, 140 :E121-E128