Disposable electrochemical sensor based on copper-electrodeposited screen-printed gold electrode and its application in sensing L-Cysteine

被引:51
|
作者
Kurniawan, Alfin [1 ]
Kurniawan, Fredi [1 ]
Gunawan, Farrel [1 ]
Chou, Shiu-Huey [2 ]
Wang, Meng-Jiy [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, 43,Sec 4,Keelung Rd, Taipei 106, Taiwan
[2] Fu Jen Catholic Univ, Dept Life Sci, New Taipei 242, Taiwan
关键词
Sulfur-containing amino acids; L-cysteine; Screen-printed gold electrode; Copper electrodeposition; Electrooxidation; Electrochemical sensor; CARBON ELECTRODES; GRAPHENE OXIDE; AMINO-ACIDS; NANOPARTICLES; OXIDATION; GLUCOSE; MECHANISM; CYSTINE; THIOLS;
D O I
10.1016/j.electacta.2018.08.140
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The development of reliable and cost-affordable electrochemical platform for rapid, sensitive, and selective detection of biological thiols has been sought after for various applications including clinical diagnosis and food monitoring. In this study, a novel disposable L-cysteine (CySH) sensor was developed based on screen-printed gold electrode (SPAuE) electrodeposited with copper. The constant potential electrodeposition was carried out at -0.4 V (versus an Ag pseudo-reference) for 480 s. The morphology and the crystal structure of electrodeposited copper were examined by scanning electron microscopy and X-ray diffraction. The analytical utility of the copper-modified SPAuE (Cu/SPAuE) was evaluated in an alkaline medium for the electrooxidation of CySH using cyclic voltammetry and amperometry techniques. The Cu/SPAuE exhibited fast response time (<5 s) and two linear ranges from 1 to 400 mu M (sensitivity of 0.028 mu A mu M-1) and 400-1800 mu M (sensitivity of 0.014 mu A mu M-1) with a detection limit (S/N = 3) of 0.21 mu M. The proposed CySH sensor also demonstrated high specificity in the presence of common interfering electroactive substances, such as sucrose, glucose, citric acid, urea, EDTA, oxalic acid, and uric acid. Furthermore, the proposed method has been successfully applied to the determination of CySH in human and rabbit blood serums without any sample pretreatment whereas the analytical recoveries were reasonably good, varying between 97.40 and 108.56% with satisfactory precision (RSD < 9%). (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 327
页数:10
相关论文
共 50 条
  • [21] Impedimetric sensor for deoxynivalenol based on electropolymerised molecularly imprinted polymer on the surface of screen-printed gold electrode
    Radi, Abd-Elgawad
    Eissa, Alsayed
    Wandan, Tarek
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 101 (15) : 2586 - 2597
  • [22] Development of a highly nanoporous platinum screen-printed electrode and its application in glucose sensing
    McCormick, Wesley
    McCrudden, Denis
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 860
  • [23] Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin
    Hatada, Mika
    Tsugawa, Wakako
    Kamio, Eri
    Loew, Noya
    Klonoff, David C.
    Sode, Koji
    BIOSENSORS & BIOELECTRONICS, 2017, 88 : 167 - 173
  • [24] Gold Nanospikes Formation on Screen-Printed Carbon Electrode through Electrodeposition Method for Non-Enzymatic Electrochemical Sensor
    Anshori, Isa
    Althof, Raih Rona
    Rizalputri, Lavita Nuraviana
    Ariasena, Eduardus
    Handayani, Murni
    Pradana, Arfat
    Akbar, Mohammad Rizki
    Syamsunarno, Mas Rizky Anggun Adipurna
    Purwidyantri, Agnes
    Prabowo, Briliant Adhi
    Annas, Muhammad Sjahrul
    Munawar, Hasim
    Yuliarto, Brian
    METALS, 2022, 12 (12)
  • [25] Disposable paper-based electrochemical sensor utilizing inkjet-printed Polyaniline modified screen-printed carbon electrode for Ascorbic acid detection
    Kit-Anan, Worrapong
    Olarnwanich, Aricha
    Sriprachuabwong, Chakrit
    Karuwan, Chanpen
    Tuantranont, Adisorn
    Wisitsoraat, Anurat
    Srituravanich, Werayut
    Pimpin, Alongkorn
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 685 : 72 - 78
  • [26] A novel and Disposable Amperometric Hydrazine Sensor based on Polydimethyldiallylamine Stabilized Copper(II)hexacyanoferrate Nanocubes modified Screen-printed Carbon Electrode
    Ramaraj, Sukanya
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    Velusamy, Vijayalakshmi
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    Pandian, Kannaiyan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5567 - 5580
  • [27] A disposable modified screen-printed electrode using egg white/ZnO rice structured composite as practical tool electrochemical sensor for formaldehyde detection and its comparative electrochemical study with Chitosan/ZnO nanocomposite
    Padmalaya, G.
    Vardhan, Kilaru Harsha
    Kumar, P. Senthil
    Ali, M. Ajmal
    Chen, Tse-Wei
    CHEMOSPHERE, 2022, 288
  • [28] Determination of Trace Lead and Cadmium in Decorative Material Using Disposable Screen-Printed Electrode Electrically Modified with Reduced Graphene Oxide/L-Cysteine/Bi-Film
    Hou, Xiaopeng
    Xiong, Benhai
    Wang, Yue
    Wang, Li
    Wang, Hui
    SENSORS, 2020, 20 (05)
  • [29] Label-Free Electrochemical Aptasensor for Determination of Chloramphenicol Based on Gold Nanocubes-Modified Screen-Printed Gold Electrode
    Hashkavayi, Ayemeh Bagheri
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Asl, Ezat Hamidi
    ELECTROANALYSIS, 2015, 27 (06) : 1449 - 1456
  • [30] Novel electrochemical sensing platform for detection of hydrazine based on modified screen-printed graphite electrode
    Mousazadeh, Farideh
    Mohammadi, Sayed Zia
    Mohammadhasani-Pour, Maryam
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2024, 14 (01): : 107 - 118