Disposable electrochemical sensor based on copper-electrodeposited screen-printed gold electrode and its application in sensing L-Cysteine

被引:51
|
作者
Kurniawan, Alfin [1 ]
Kurniawan, Fredi [1 ]
Gunawan, Farrel [1 ]
Chou, Shiu-Huey [2 ]
Wang, Meng-Jiy [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, 43,Sec 4,Keelung Rd, Taipei 106, Taiwan
[2] Fu Jen Catholic Univ, Dept Life Sci, New Taipei 242, Taiwan
关键词
Sulfur-containing amino acids; L-cysteine; Screen-printed gold electrode; Copper electrodeposition; Electrooxidation; Electrochemical sensor; CARBON ELECTRODES; GRAPHENE OXIDE; AMINO-ACIDS; NANOPARTICLES; OXIDATION; GLUCOSE; MECHANISM; CYSTINE; THIOLS;
D O I
10.1016/j.electacta.2018.08.140
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The development of reliable and cost-affordable electrochemical platform for rapid, sensitive, and selective detection of biological thiols has been sought after for various applications including clinical diagnosis and food monitoring. In this study, a novel disposable L-cysteine (CySH) sensor was developed based on screen-printed gold electrode (SPAuE) electrodeposited with copper. The constant potential electrodeposition was carried out at -0.4 V (versus an Ag pseudo-reference) for 480 s. The morphology and the crystal structure of electrodeposited copper were examined by scanning electron microscopy and X-ray diffraction. The analytical utility of the copper-modified SPAuE (Cu/SPAuE) was evaluated in an alkaline medium for the electrooxidation of CySH using cyclic voltammetry and amperometry techniques. The Cu/SPAuE exhibited fast response time (<5 s) and two linear ranges from 1 to 400 mu M (sensitivity of 0.028 mu A mu M-1) and 400-1800 mu M (sensitivity of 0.014 mu A mu M-1) with a detection limit (S/N = 3) of 0.21 mu M. The proposed CySH sensor also demonstrated high specificity in the presence of common interfering electroactive substances, such as sucrose, glucose, citric acid, urea, EDTA, oxalic acid, and uric acid. Furthermore, the proposed method has been successfully applied to the determination of CySH in human and rabbit blood serums without any sample pretreatment whereas the analytical recoveries were reasonably good, varying between 97.40 and 108.56% with satisfactory precision (RSD < 9%). (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 327
页数:10
相关论文
共 50 条
  • [1] Sensitive electrochemical detection of L-Cysteine at a screen-printed diamond electrode
    Matsunaga, Tomohiro
    Kondo, Takeshi
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Tojo, Toshifumi
    Yuasa, Makoto
    CARBON, 2021, 173 (173) : 395 - 402
  • [2] A Disposable Copper (II) Ion Biosensor Based on Self-Assembly of L-Cysteine on Gold Nanoparticle-Modified Screen-Printed Carbon Electrode
    See, Wong Pooi
    Nathan, Sheila
    Heng, Lee Yook
    JOURNAL OF SENSORS, 2011, 2011
  • [3] ELECTROCHEMICAL DETERMINATION OF METHOTREXATE AT A DISPOSABLE SCREEN-PRINTED ELECTRODE AND ITS APPLICATION STUDIES
    Wang, Shi
    Qi, Zheqiong
    Huang, Hongke
    Ding, Hong
    ANALYTICAL LETTERS, 2012, 45 (12) : 1658 - 1669
  • [4] In Situ Deposition of Gold Nanoparticles and L-Cysteine on Screen-Printed Carbon Electrode for Rapid Electrochemical Determination of As(III) in Water and Tea
    Wang, Wenjing
    Yi, Zhijian
    Liang, Qiongxin
    Zhen, Junjie
    Wang, Rui
    Li, Mei
    Zeng, Lingwen
    Li, Yongfang
    BIOSENSORS-BASEL, 2023, 13 (01):
  • [5] Disposable nitrite sensor based on hemoglobin-colloidal gold nanoparticle modified screen-printed electrode
    Xu, XX
    Liu, SQ
    Li, B
    Ju, HX
    ANALYTICAL LETTERS, 2003, 36 (11) : 2427 - 2442
  • [6] A disposable screen printed graphene-carbon paste electrode and its application in electrochemical sensing
    Karuwan, Chanpen
    Wisitsoraat, Anurat
    Phokharatkul, Ditsayut
    Sriprachuabwong, Chakrit
    Lomas, Tanom
    Nacapricha, Duangjai
    Tuantranont, Adisorn
    RSC ADVANCES, 2013, 3 (48): : 25792 - 25799
  • [7] A disposable molecularly imprinted electrochemical sensor based on screen-printed electrode modified with ordered mesoporous carbon and gold nanoparticles for determination of ractopamine
    Ma, Min
    Zhu, Pei
    Pi, Fuwei
    Ji, Jian
    Sun, Xiulan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 775 : 171 - 178
  • [8] Screen-printed gold electrode with gold nanoparticles modification for simultaneous electrochemical determination of lead and copper
    Wan, Hao
    Sun, Qiyong
    Li, Haibo
    Sun, Fei
    Hu, Ning
    Wang, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 336 - 342
  • [9] The Ultra-sensitive Electrochemical Detection of As(III) in Ground Water Using Disposable L-cysteine/Lipoic Acid Functionalised Gold Nanoparticle Modified Screen-Printed Electrodes
    Jijana, Abongile Nwabisa
    Mphuthi, Ntsoaki
    Shumbula, Poslet
    Vilakazi, Sibulelo
    Sikhwivhilu, Lucky
    ELECTROCATALYSIS, 2021, 12 (03) : 310 - 325
  • [10] The Ultra-sensitive Electrochemical Detection of As(III) in Ground Water Using Disposable L-cysteine/Lipoic Acid Functionalised Gold Nanoparticle Modified Screen-Printed Electrodes
    Abongile Nwabisa Jijana
    Ntsoaki Mphuthi
    Poslet Shumbula
    Sibulelo Vilakazi
    Lucky Sikhwivhilu
    Electrocatalysis, 2021, 12 : 310 - 325