Overlapping intramedullary nailing after failed minimally invasive locked plating for osteoporotic distal femur fractures - Report of 2 cases

被引:11
作者
Yoo, Je-Hyun [1 ]
Kim, Seok-Woo [1 ]
Kwak, Yoon-Hae [1 ]
Kim, Hyung-Jun [1 ]
机构
[1] Hallym Univ, Sch Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang 431070, South Korea
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 06期
关键词
Distal femur; Osteoporotic fracture; Failed MIPO; Overlapping IM nailing; FEMORAL FRACTURES; INTERNAL-FIXATION; EVOLUTION;
D O I
10.1016/j.injury.2015.01.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Minimally invasive plate osteosynthesis (MIPO) using a locking plate has been widely used for distal femur fractures in the elderly with osteoporosis and yielded favourable results. However, implant failure and subsequent periplate fracture have still occurred owing to the controversy of concepts regarding locked plating. The treatment after failed MIPO in elderly patients is very challenging and has been not yet addressed definitely in the literature, although several options can be considered. We report the successful outcomes of two cases treated with overlapping intramedullary (IM) nailing for implant failure and periplate fracture after MIPO for osteoporotic distal femur fracture, along with simple tips of distal interlocking of IM nail. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1174 / 1177
页数:4
相关论文
共 15 条
  • [1] A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis
    Bottlang, Michael
    Doornink, Josef
    Byrd, Gregory D.
    Fitzpatrick, Daniel C.
    Madey, Steven M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) : 620 - 627
  • [2] Guidelines for the clinical application of the LCP
    Gautier, E
    Sommer, C
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : 63 - 76
  • [3] The effect of implant overlap on the mechanical properties of the femur
    Harris, T
    Ruth, JT
    Szivek, J
    Haywood, B
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (05): : 930 - 935
  • [4] Locking Plates for Distal Femur Fractures: Is There a Problem With Fracture Healing?
    Henderson, Christopher E.
    Kuhl, Lori L.
    Fitzpatrick, Daniel C.
    Marsh, J. L.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 : S8 - S14
  • [5] Choosing a proper working length can improve the lifespan of locked plates A biomechanical study
    Hoffmeier, Konrad L.
    Hofmann, Gunther O.
    Mueckley, Thomas
    [J]. CLINICAL BIOMECHANICS, 2011, 26 (04) : 405 - 409
  • [6] Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur
    Krettek, C
    Müller, M
    Miclau, T
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 14 - 23
  • [7] The evolution of locked plates
    Kubiak, Erik N.
    Fulkerson, Eric
    Strauss, Eric
    Egol, Kfdineth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 189 - 200
  • [8] KYLE RF, 1991, CLIN ORTHOP RELAT R, P169
  • [9] Femur-LISS and distal femoral nail for fixation of distal femoral fractures -: Are there differences in outcome and complications?
    Markmiller, M
    Konrad, G
    Südkamp, N
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 252 - 257
  • [10] Evolution of the internal fixation of long bone fractures - The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    Perren, SM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08): : 1093 - 1110