Biaxial sensing suture breakage warning system for robotic surgery

被引:13
|
作者
Dai, Yuan [1 ,2 ]
Abiri, A. [2 ,3 ]
Pensa, J. [2 ,3 ]
Liu, S. [1 ]
Paydar, O. [2 ,3 ]
Sohn, H. [1 ]
Sun, S. [2 ,3 ]
Pellionisz, P. A. [2 ,3 ]
Pensa, C. [3 ]
Dutson, E. P. [2 ,4 ]
Grundfest, W. S. [1 ,2 ,3 ,4 ]
Candler, R. N. [1 ,2 ,3 ,5 ]
机构
[1] Univ Calif Los Angeles, Dept Elect & Comp Engn, Los Angeles, CA 90095 USA
[2] Ctr Adv Surg & Intervent Technol CASIT, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Biomed Engn, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Surg, Los Angeles, CA 90095 USA
[5] Calif NanoSyst Inst, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
Haptic feedback; Shear sensor; Robotic surgery; Force sensor; Haptics; Da Vinci; FORCE; FEEDBACK; STRESS; DAMAGE;
D O I
10.1007/s10544-018-0357-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The number of procedures performed with robotic surgery may exceed one million globally in 2018. The continual lack of haptic feedback, however, forces surgeons to rely on visual cues in order to avoid breaking sutures due to excessive applied force. To mitigate this problem, the authors developed and validated a novel grasper-integrated system with biaxial shear sensing and haptic feedback to warn the operator prior to anticipated suture breakage. Furthermore, the design enables facile suture manipulation without a degradation in efficacy, as determined via measured tightness of resulting suture knots. Biaxial shear sensors were integrated with a da Vinci robotic surgical system. Novice subjects (n=17) were instructed to tighten 10 knots, five times with the Haptic Feedback System (HFS) enabled, five times with the system disabled. Seven suture failures occurred in trials with HFS enabled while seventeen occurred in trials without feedback. The biaxial shear sensing system reduced the incidence of suture failure by 59% (p=0.0371). It also resulted in 25% lower average applied force in comparison to trials without feedback (p=0.00034), which is relevant because average force was observed to play a role in suture breakage (p=0.03925). An observed 55% decrease in standard deviation of knot quality when using the HFS also indicates an improvement in consistency when using the feedback system. These results suggest this system may improve outcomes related to knot tying tasks in robotic surgery and reduce instances of suture failure while not degrading the quality of knots produced.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Mid-infrared robotic laser surgery system in neurosurgery
    Omori, Shigeru
    Nakumura, Ryoichi
    Muragaki, Yoshihiro
    Sakuma, Ichiro
    Miura, Katsuhiro
    Doi, Masao
    Iseki, Hiroshi
    COMPLEX MEDICAL ENGINEERING, 2007, : 47 - +
  • [42] Design and Implementation of a Robotic Surgery Training Experience Logging System
    Baldea, Kristin G.
    Thorwarth, Ryan
    Bajic, Petar
    Quek, Marcus L.
    Gupta, Gopal N.
    JOURNAL OF SURGICAL EDUCATION, 2017, 74 (06) : 1047 - 1051
  • [43] Initial experience with a novel robotic surgical system in abdominal surgery
    Joseph El Dahdah
    Mouhammad Halabi
    Jado Kamal
    Michael E. Zenilman
    Hatem Moussa
    Journal of Robotic Surgery, 2023, 17 : 841 - 846
  • [44] Robotic Surgery Simulator Support, Vision System and Test Subject
    Johnston, M. L.
    Riofrio, J.
    Gettens, R. T. T.
    2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [45] Surgical application of a new robotic system for paranasal sinus surgery
    Steinhart, H
    Bumm, K
    Wurm, J
    Vogele, M
    Iro, H
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2004, 113 (04): : 303 - 309
  • [46] Robotic spinal surgery system with force feedback for teleoperated drilling
    Rezazadeh, Sina
    Bai, Weibang
    Sun, Mingjing
    Chen, Shihang
    Lin, Yanping
    Cao, Qixin
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (14): : 500 - 505
  • [47] Initial experience with a novel robotic surgical system in abdominal surgery
    El Dahdah, Joseph
    Halabi, Mouhammad
    Kamal, Jado
    Zenilman, Michael E.
    Moussa, Hatem
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (03) : 841 - 846
  • [48] Development and evaluation of a training module for the clinical introduction of the da Vinci robotic system in visceral and vascular surgery
    Mehrabi, A.
    Yetimoglu, C. L.
    Nickkholgh, A.
    Kashfi, A.
    Kienle, P.
    Konstantinides, L.
    Ahmadi, M. R.
    Fonouni, H.
    Schemmer, P.
    Friess, H.
    Gebhard, M. M.
    Buechler, M. W.
    Schmidt, J.
    Gutt, C. N.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (09): : 1376 - 1382
  • [49] Development and evaluation of a training module for the clinical introduction of the da Vinci robotic system in visceral and vascular surgery
    A. Mehrabi
    C. L. Yetimoglu
    A. Nickkholgh
    A. Kashfi
    P. Kienle
    L. Konstantinides
    M. R. Ahmadi
    H. Fonouni
    P. Schemmer
    H. Friess
    M. M. Gebhard
    M. W. Büchler
    J. Schmidt
    C. N. Gutt
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20 : 1376 - 1382
  • [50] A new system for evaluation of armrest use in robotic surgery and validation of a new ergonomic concept - armrest load
    Yang, K.
    Perez, M.
    Perrenot, C.
    Hubert, N.
    Felblinger, J.
    Hubert, J.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (04): : 604 - 612