Biaxial sensing suture breakage warning system for robotic surgery

被引:13
|
作者
Dai, Yuan [1 ,2 ]
Abiri, A. [2 ,3 ]
Pensa, J. [2 ,3 ]
Liu, S. [1 ]
Paydar, O. [2 ,3 ]
Sohn, H. [1 ]
Sun, S. [2 ,3 ]
Pellionisz, P. A. [2 ,3 ]
Pensa, C. [3 ]
Dutson, E. P. [2 ,4 ]
Grundfest, W. S. [1 ,2 ,3 ,4 ]
Candler, R. N. [1 ,2 ,3 ,5 ]
机构
[1] Univ Calif Los Angeles, Dept Elect & Comp Engn, Los Angeles, CA 90095 USA
[2] Ctr Adv Surg & Intervent Technol CASIT, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Biomed Engn, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Surg, Los Angeles, CA 90095 USA
[5] Calif NanoSyst Inst, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
Haptic feedback; Shear sensor; Robotic surgery; Force sensor; Haptics; Da Vinci; FORCE; FEEDBACK; STRESS; DAMAGE;
D O I
10.1007/s10544-018-0357-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The number of procedures performed with robotic surgery may exceed one million globally in 2018. The continual lack of haptic feedback, however, forces surgeons to rely on visual cues in order to avoid breaking sutures due to excessive applied force. To mitigate this problem, the authors developed and validated a novel grasper-integrated system with biaxial shear sensing and haptic feedback to warn the operator prior to anticipated suture breakage. Furthermore, the design enables facile suture manipulation without a degradation in efficacy, as determined via measured tightness of resulting suture knots. Biaxial shear sensors were integrated with a da Vinci robotic surgical system. Novice subjects (n=17) were instructed to tighten 10 knots, five times with the Haptic Feedback System (HFS) enabled, five times with the system disabled. Seven suture failures occurred in trials with HFS enabled while seventeen occurred in trials without feedback. The biaxial shear sensing system reduced the incidence of suture failure by 59% (p=0.0371). It also resulted in 25% lower average applied force in comparison to trials without feedback (p=0.00034), which is relevant because average force was observed to play a role in suture breakage (p=0.03925). An observed 55% decrease in standard deviation of knot quality when using the HFS also indicates an improvement in consistency when using the feedback system. These results suggest this system may improve outcomes related to knot tying tasks in robotic surgery and reduce instances of suture failure while not degrading the quality of knots produced.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Implementation of a Robotic Surgical Program With the Dexter Robotic Surgery System: Initial Experiences in Cholecystectomy
    Hotz, Anne-Sophie
    Seeger, Nico
    Gantner, Lukas
    Grieder, Felix
    Breitenstein, Stefan
    WORLD JOURNAL OF SURGERY, 2025,
  • [32] Trajectory-Optimized Sensing for Active Search of Tissue Abnormalities in Robotic Surgery
    Salman, Hadi
    Ayvali, Elif
    Srivatsan, Rangaprasad Arun
    Ma, Yifei
    Zevallos, Nicolas
    Yasin, Rashid
    Wang, Long
    Simaan, Nabil
    Choset, Howie
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2018, : 5356 - 5363
  • [33] Effectiveness of a vision-based handle trajectory monitoring system in studying robotic suture operation
    Gaojie Chen
    Lu Li
    Jacques Hubert
    Bin Luo
    Kun Yang
    Xinghuan Wang
    Journal of Robotic Surgery, 2023, 17 : 2791 - 2798
  • [34] Effectiveness of a vision-based handle trajectory monitoring system in studying robotic suture operation
    Chen, Gaojie
    Li, Lu
    Hubert, Jacques
    Luo, Bin
    Yang, Kun
    Wang, Xinghuan
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (06) : 2791 - 2798
  • [35] Robotic Gastric Bypass Surgery in the Swiss Health Care System: Analysis of Hospital Costs and Reimbursement
    Monika E. Hagen
    Peter Rohner
    Minoa K. Jung
    Nicolas Amirghasemi
    Nicolas C. Buchs
    Jassim Fakhro
    Leo Buehler
    Philippe Morel
    Obesity Surgery, 2017, 27 : 2099 - 2105
  • [36] Robotic Gastric Bypass Surgery in the Swiss Health Care System: Analysis of Hospital Costs and Reimbursement
    Hagen, Monika E.
    Rohner, Peter
    Jung, Minoa K.
    Amirghasemi, Nicolas
    Buchs, Nicolas C.
    Fakhro, Jassim
    Buehler, Leo
    Morel, Philippe
    OBESITY SURGERY, 2017, 27 (08) : 2099 - 2105
  • [37] The da Vinci robotic surgery system for the management of endometrial cancer: a single-center experience
    Latifah, Hassan M.
    Khan, Mahmoud Anis
    Nadreen, Farah
    Latifah, Abdullah
    Asaad, Alanoud
    Baradwan, Saeed
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [38] Novel virtual reality based training system for fine motor skills: Towards developing a robotic surgery training system
    Vasudevan, Madhan Kumar
    Isaac, Joseph H. R.
    Sadanand, Venkatraman
    Muniyandi, Manivannan
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (06): : 1 - 14
  • [39] Unilateral Teleoperation Design for a Robotic Endoscopic Pituitary Surgery System
    Dede, M. I. C.
    Maaroof, O. W.
    Ates, G.
    Berker, M.
    Isikay, I.
    Hanalioglu, S.
    NEW TRENDS IN MEDICAL AND SERVICE ROBOTS: DESIGN, ANALYSIS AND CONTROL, 2018, 48 : 101 - 115
  • [40] A Novel Sensing System for Robotic Cochlear Implants Electrode Array Placement
    Hou, Lei
    Du, Xinli
    Boulgouris, Nikolaos V.
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 1133 - 1137