High-resolution KLM auger spectra of Ni metal excited by X-rays

被引:5
作者
Egri, S. [1 ]
Koever, L. [2 ]
Drube, W. [3 ]
Cserny, I. [2 ]
Novak, M. [2 ]
机构
[1] Univ Debrecen, Dept Expt Phys, H-4026 Debrecen, Hungary
[2] Hungarian Acad Sci, Inst Nucl Res, H-4026 Debrecen, Hungary
[3] Hamburger Synchrontronstschlungslab Deutschen Ele, D-22603 Hamburg, Germany
关键词
Auger spectra; NiKLM; synchrotron radiation; intrinsic excitations; transition energy; relative intensity; 3d transition metals;
D O I
10.1016/j.elspec.2007.12.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
KLM Auger spectra of Ni metal were measured with high energy resolution and high statistical accuracy using monochromatic synchrotron radiation. The spectra were corrected for the background from inelastically scattered electrons using partial intensity analysis where the electron trajectories were calculated by Monte Carlo simulation. Following background correction, the corrected spectra were fitted to model peaks taking into account intrinsic excitations. The measured transition energy of the most intense KL2M3 (D-1(2)) Auger line is 7388.1 eV (0.4). The obtained relative intensities and energies of the Auger diagram lines are compared to published calculations as well as to experimental data for other 3d transition metals. In addition, the presence of Ni 3s, 3p photoelectron peaks in the spectra excited internally by Ni K alpha X-rays is shown. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [41] Feasibility of in-line instruments for high-resolution inelastic X-ray scattering
    Sturhahn, W.
    Toellner, T. S.
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 229 - 237
  • [42] Application of local tomography technique to high-resolution synchrotron X-ray imaging
    Ohgaki, Tomomi
    Toda, Hiroyuki
    Uesugi, Kentaro
    Kobayashi, Toshiro
    Makii, Koichi
    Takagi, Toshiaki
    Aruga, Yasuhiro
    THERMEC 2006, PTS 1-5, 2007, 539-543 : 287 - +
  • [43] Hybrid Measurement of CT and Strain Distribution of internal Crack Using Synchrotron High-Energy Monochromatic X-Rays
    Tanaka, Keisuke
    Shobu, Takahisa
    Kimachi, Hiroshi
    MECHANICAL STRESS EVALUATION BY NEUTRONS AND SYNCHROTRON RADIATION, 2010, 652 : 202 - +
  • [44] Diamond x-ray optics: Transparent, resilient, high-resolution, and wavefront preserving
    Shvyd'ko, Yuri
    Blank, Vladimir
    Terentyev, Sergey
    MRS BULLETIN, 2017, 42 (06) : 437 - 444
  • [45] Development of an X-ray interferometer for high-resolution phase-contrast X-Ray imaging
    Hirano, K
    Momose, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (12B): : L1556 - L1558
  • [46] A high-resolution dose calculation engine for X-ray microbeams radiation therapy
    Keshmiri, Sarvenaz
    Brocard, Sylvan
    Serduc, Raphael
    Adam, Jean-Francois
    MEDICAL PHYSICS, 2022, 49 (06) : 3999 - 4017
  • [47] Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates
    Fournier, P.
    Crosbie, J. C.
    Cornelius, I.
    Berkvens, P.
    Donzelli, M.
    Clavel, A. H.
    Rosenfeld, A. B.
    Petasecca, M.
    Lerch, M. L. F.
    Brauer-Krisch, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (14) : N349 - N361
  • [48] High-speed X-ray microscopy by use of high-resolution zone plates and synchrotron radiation
    Hou, Qiyue
    Wang, Zhili
    Gao, Kun
    Pan, Zhiyun
    Wang, Dajiang
    Ge, Xin
    Zhang, Kai
    Hong, Youli
    Zhu, Peiping
    Wu, Ziyu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (05) : 1327 - 1330
  • [49] High-resolution X-ray computed tomography in geosciences: A review of the current technology and applications
    Cnudde, V.
    Boone, M. N.
    EARTH-SCIENCE REVIEWS, 2013, 123 : 1 - 17
  • [50] Void growth and coalescence in model materials investigated by high-resolution X-ray microtomography
    Hosokawa, Akihide
    Wilkinson, David S.
    Kang, Jidong
    Kobayashi, Masakazu
    Toda, Hiroyuki
    INTERNATIONAL JOURNAL OF FRACTURE, 2013, 181 (01) : 51 - 66