High-Throughput Determination of Major Mycotoxins with Human Health Concerns in Urine by LC-Q TOF MS and Its Application to an Exposure Study

被引:8
|
作者
Pallares, Noelia [1 ]
Carballo, Dionisia [2 ]
Ferrer, Emilia [1 ]
Rodriguez-Carrasco, Yelko [1 ]
Berrada, Houda [1 ]
机构
[1] Univ Valencia, Dept Prevent Med & Publ Hlth Food Sci Toxicol & F, Fac Pharm, Burjassot 46100, Spain
[2] Natl Univ Asuncion, Fac Agr Sci, San Lorenzo 2160, Paraguay
关键词
biomarkers; mycotoxins; QuEChERS; LC-ESI-QTOF; urine; risk assessment; SAO-PAULO; OCHRATOXIN; ZEARALENONE; AFLATOXINS; BIOMARKERS; DEOXYNIVALENOL; METABOLISM; TOXICITY; SERUM;
D O I
10.3390/toxins14010042
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Human biomonitoring constitutes a suitable tool to assess exposure to toxins overcoming the disadvantages of traditional methods. Urine constitutes an accessible biological matrix in biomonitoring studies. Mycotoxins are secondary metabolites produced naturally by filamentous fungi that produce a wide range of adverse health effects. Thus, the determination of urinary mycotoxin levels is a useful tool for assessing the individual exposure to these food contaminants. In this study, a suitable methodology has been developed to evaluate the presence of aflatoxin B2 (AFB2), aflatoxin (AFG2), ochratoxin A (OTA), ochratoxin B (OTB), zearalenone (ZEA), and alpha-zearalenol (alpha-ZOL) in urine samples as exposure biomarkers. For this purpose, different extraction procedures, namely, the Solid Phase Extraction (SPE); Dispersive Liquid-Liquid Microextraction (DLLME); and Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods were assessed, followed by Liquid Chromatography coupled to Quadrupole Time of Flight Mass Spectrometry with Electrospray Ionization (LC-ESI-QTOF-MS) determination. Then, the proposed methodology was applied to determine mycotoxin concentrations in 56 human urine samples from volunteers and to estimate the potential risk of exposure. The results obtained revealed that 55% of human urine samples analyzed resulted positive for at least one mycotoxin. Among all studied mycotoxins, only AFB2, AFG2, and OTB were detected with incidences of 32, 41, and 9%, respectively, and levels in the range from <LOQ to 69.42 mu g/L. Risk assessment revealed a potential health risk, obtaining MoE values < 10,000. However, it should be highlighted that few samples were contaminated, and that more data about mycotoxin excretion rates and their BMDL10 values are needed for a more accurate risk assessment.
引用
收藏
页数:13
相关论文
共 48 条
  • [21] High Throughput, Sensitive LC-MS/MS Determination of Bile Acids in Mouse Feces and its Application to Monitoring their Levels of Excretion
    Saracut, Claudiu
    Copotoiu, Constantin
    Molnar, Calin
    Farczadi, Lenard
    Todoran, Nicoleta
    Carje, Anca
    Vlase, Laurian
    REVISTA DE CHIMIE, 2016, 67 (06): : 1154 - 1157
  • [22] Determination of Nateglinide in Human Plasma by LC-ESI-MS and Its Application to Bioequivalence Study
    Han, De-En
    Zheng, Yi
    Li, Ning
    Zhao, Di
    Zhang, Ge
    Yan, Hefeng
    Zhang, Lingli
    Sun, Wei
    Wu, Ya-Ning
    Lu, Yang
    Chen, Xijing
    CHROMATOGRAPHIA, 2010, 71 (3-4) : 299 - 304
  • [23] Development and validation of LC-MS/MS methods for the determination of EVT201 and its five metabolites in human urine: Application to a mass balance study
    Liu, Man
    Wang, Xiaolin
    Zhang, Dan
    Zhang, Lina
    Pan, Chunmiao
    Liu, Huichen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1223
  • [24] Development of Simultaneous Determination Method of Hydroxylated Polycyclic Aromatic Hydrocarbons in Urine by LC/MS/MS and Its Application to Assessment of Polycyclic Aromatic Hydrocarbons Exposure
    Hirai, Tetsuya
    Kinoshita, Hiroaki
    Okamura, Hideo
    Yano, Yoshiji
    Nakano, Takeshi
    BUNSEKI KAGAKU, 2012, 61 (11) : 925 - 930
  • [25] An improved LC-MS/MS method for quantitative determination of metolazone in human plasma and its application to a pharmacokinetic study
    Jia, Yanyan
    Zhang, Yan
    Wang, Chao
    Wang, Zhirui
    Liu, Yu
    Wang, Jingwen
    Wen, Aidong
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (10) : 1138 - 1143
  • [26] Development and validation of a sensitive LC-MS/MS assay for the quantification of nizatidine in human plasma and urine and its application to pharmacokinetic study
    Shang, De-Wei
    Wang, Zhan-Zhang
    Ni, Xiao-Jia
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 998 : 80 - 87
  • [27] A high-throughput method for the determination of 14 UV-filters in human plasma by LC-MS/MS: Minimize interferences from proteins and phospholipids in the matrix
    Yang, Wucheng
    Feng, Jianglu
    Liang, Wenyao
    Nie, Mingxia
    Tan, Jianhua
    Fan, Ruifang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1237
  • [28] Development of simple and rapid LC-MS/MS method for determination of celecoxib in human plasma and its application to bioequivalence study
    Park, Mi-Sun
    Shim, Wang-Seob
    Yim, Sung-Vin
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 137 - 141
  • [29] Highly sensitive LC-MS/MS-ESI method for determination of phenelzine in human plasma and its application to a human pharmacokinetic study
    Kallem, Raja Reddy
    Jillela, Bhupathi
    Ravula, Arun Reddy
    Samala, Ramakrishna
    Andy, Adinarayana
    Ramesh, Mullangi
    Rao, J. V. L. N. Seshagiri
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 126 - 132
  • [30] A simple, sensitive, and high-throughput LC-APCI-MS/MS method for simultaneous determination of vitamin K1, vitamin K1 2,3-epoxide in human plasma and its application to a clinical pharmacodynamic study of warfarin
    Hu, Kuan
    Li, Yan
    Ding, Ru
    Zhai, Yu
    Chen, Lin
    Qian, Wei
    Yang, Jin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 : 82 - 91