Echogenic Technology Can Improve Needle Visibility During Ultrasound-Guided Regional Anesthesia

被引:83
作者
Hebard, Simon [1 ]
Hocking, Graham [1 ,2 ]
机构
[1] Sir Charles Gairdner Hosp, Perth, WA 6009, Australia
[2] Univ Western Australia, Sch Med & Pharmacol, Crawley, WA, Australia
关键词
IN-VITRO; ULTRASONOGRAPHIC ECHOGENICITY; BIOPSY NEEDLES; VISUALIZATION; TIP; GUIDANCE; STANDARD;
D O I
10.1097/AAP.0b013e31820d4349
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Needle tip visualization is fundamental to the safety and efficacy of ultrasound-guided regional anesthesia (UGRA). It can be extremely challenging especially at steep insertion angles. We assessed whether an echogenic needle improved tip visibility during UGRA by anesthesiologists performing their normal in-plane technique. The visibility of the Pajunk Sonoplex (echogenic) and the Pajunk Uniplex (control) needle were compared during 60 nerve blocks (30 femoral, 30 sciatic) in this randomized controlled trial. All ultrasound imaging was recorded for analysis. The anesthesiologist subjectively estimated the percentage time they had visualized the needle tip (5-point scale: 1 [0%-20%], 2 [20%-40%], 3 [40%-60%], 4 [60%-80%], 5 [80%-100%]). The actual time the tip was in view, angle of needle insertion, target depth, and procedure time were subsequently measured objectively by a single investigator. The Sonoplex group had both subjectively and objectively better tip visibility (P = 0.002), despite having larger mean body mass index (29.0 vs 25.0 kg/m(2), P = 0.01) and steeper mean insertion angle (31 vs 22 degrees, P = 0.03). Objective percentage tip visibility, during in-plane UGRA, reduced by 12% for every 10-degree increase in insertion angle with the control. Tip visibility with the Sonoplex was independent of insertion angle over the range studied (0-57 degrees, P = 0.95). This finding occurred when nonexpert anesthesiologists performed their standard UGRA technique. A needle that is visible for a greater percentage of time has potential safety and efficacy implications.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 24 条
  • [1] Preliminary Results of the Australasian Regional Anaesthesia Collaboration A Prospective Audit of More Than 7000 Peripheral Nerve and Plexus Blocks for Neurologic and Other Complications
    Barrington, Michael J.
    Watts, Steve A.
    Gledhill, Samuel R.
    Thomas, Rowan D.
    Said, Simone A.
    Snyder, Gabriel L.
    Tay, Valerie S.
    Jamrozik, Konrad
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (06) : 534 - 541
  • [2] Echogenic polymer coating: Does it improve needle visualization in sonographically guided biopsy?
    Bergin, D
    Pappas, JN
    Hwang, JJ
    Sheafor, DH
    Paulson, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) : 1188 - 1190
  • [3] Controlling needle tip progression during ultrasound-guided regional anesthesia using the hydrolocalization technique
    Bloc, Sebastien
    Ecoffey, Claude
    Dhonneur, Gilles
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2008, 33 (04) : 382 - 383
  • [4] NEEDLE TIP ECHOGENICITY - A STUDY WITH REAL-TIME ULTRASOUND
    BONDESTAM, S
    KREULA, J
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (07) : 555 - 560
  • [5] An in-vitro study to understand successful free-hand ultrasound guided intervention
    Bradley, MJ
    [J]. CLINICAL RADIOLOGY, 2001, 56 (06) : 495 - 498
  • [6] Visualisation of needle position using ultrasonography
    Chapman, GA
    Johnson, D
    Bodenham, AR
    [J]. ANAESTHESIA, 2006, 61 (02) : 148 - 158
  • [7] Needle Visualization in Ultrasound-Guided Regional Anesthesia: Challenges and Solutions
    Chin, Ki Ann
    Perlas, Anahi
    Chan, Vincent W. S.
    Brull, Richard
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2008, 33 (06) : 532 - 544
  • [8] Relative ultrasonographic echogenicity of standard, dimpled, and polymeric-coated needles
    Culp, WC
    McCowan, TC
    Goertzen, TC
    Habbe, TG
    Hummel, MM
    LeVeen, RF
    Anderson, JC
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (03) : 351 - 358
  • [9] Investigation of a new echogenic needle for use with ultrasound peripheral nerve blocks
    Deam, R. K.
    Kluger, R.
    Barrington, M. J.
    Mccutcheon, C. A.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (04) : 582 - 586
  • [10] Sonographic Identification of Needle Tip by Specialists and Novices A Blinded Comparison of 5 Regional Block Needles in Fresh Human Cadavers
    Edgcombe, Hilary
    Hocking, Graham
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (02) : 207 - 211