Three-dimensional Cardiac MR Imaging: Related Techniques and Clinical Applications

被引:14
|
作者
Amano, Yasuo [1 ,2 ]
Yanagisawa, Fumi [1 ,2 ]
Tachi, Masaki [2 ]
Asai, Kuniya [3 ]
Suzuki, Yasuyuki [4 ]
Hashimoto, Hidenobu [1 ,5 ]
Ishihara, Kiyohisa [6 ]
Kumita, Shinichiro [2 ]
机构
[1] Nihon Univ Hosp, Dept Radiol, Chiyoda Ku, 1-6 Kanda Surugadai, Tokyo 1018309, Japan
[2] Nippon Med Sch, Dept Radiol, Tokyo, Japan
[3] Nippon Med Sch, Dept Cardiol, Tokyo, Japan
[4] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[5] Toho Univ, Dept Cardiol, Omori Med Ctr, Tokyo, Japan
[6] Toshima Med Ctr, Tokyo, Japan
基金
日本学术振兴会;
关键词
three-dimensional imaging; cardiac magnetic resonance imaging; steady-state free precession; gadolinium; fast data acquisition; CARDIOVASCULAR MAGNETIC-RESONANCE; K-T SENSE; BREATH-HOLD; SPATIAL-RESOLUTION; MYOCARDIAL SCAR; HEART; ENHANCEMENT; FEASIBILITY; ANGIOGRAPHY; VIABILITY;
D O I
10.2463/mrms.rev.2016-0116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) cardiac magnetic resonance (MR) imaging has several advantages, including the easy coverage of the entire heart without misregistration, reduction of breath-holding times, and availability for postprocessing reconstruction. These advantages are associated with some techniques such as breath-hold or navigator gating and parallel imaging. However, the image quality of 3D cardiac MR images is compromised by the use of a shorter repetition time and parallel imaging. Thus, a steady-state free precession sequence, contrast agent administration, and presaturation pulses are used to maintain the image quality. In this review, we introduce the MR imaging techniques used in 3D cardiac MR imaging and demonstrate the typical 3D cardiac MR images, followed by discussion about their advantages and disadvantages.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 50 条
  • [31] Three-dimensional Fourier ghost imaging
    Huang, Jian
    Shi, Dongfeng
    Yuan, Kee
    Hu, Shunxing
    OPTIK, 2020, 219
  • [32] Three-dimensional imaging of carbon nanotubes
    Kizuka, T
    Sumi, T
    Bansho, S
    Saito, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (1AB): : L56 - L58
  • [33] Three-dimensional detectors for neutron imaging
    Mendicino, R.
    Betta, G. -F. Dalla
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 129 - 140
  • [34] Applications of Cardiac MR Imaging in Electrophysiology Current Status and Future Needs
    Okada, David R.
    Wu, Katherine C.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2019, 27 (03) : 465 - +
  • [35] Three-dimensional ultrasound imaging of the vasculature
    Fenster, A
    Lee, D
    Sherebrin, S
    Rankin, R
    Downey, D
    ULTRASONICS, 1998, 36 (1-5) : 629 - 633
  • [36] Three-dimensional echography: Cardiovascular applications
    Le Tourneau, T.
    Polge, A. S.
    Gautier, C.
    Deklunder, G.
    JOURNAL DE RADIOLOGIE, 2006, 87 (12): : 1993 - 2004
  • [37] Three-dimensional time-of-flight MR angiography and MR imaging versus conventional angiography in carotid artery dissections
    Stringaris, K
    Liberopoulos, K
    Giaka, E
    Kokkinis, K
    Bastounis, E
    Klonaris, EC
    Balas, P
    INTERNATIONAL ANGIOLOGY, 1996, 15 (01) : 20 - 25
  • [38] Clinical Evaluation of Three-Dimensional Late Enhancement MRI
    Bratis, Konstantinos
    Henningsson, Markus
    Grigoratos, Chrisanthos
    Dell' Omodarme, Matteo
    Chasapides, Konstantinos
    Botnar, Rene
    Nagel, Eike
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) : 1675 - 1683
  • [39] Development of three-dimensional MR neurography using an optimized combination of compressed sensing and parallel imaging
    Aoike, Takuya
    Fujima, Noriyuki
    Yoneyama, Masami
    Fujiwara, Taro
    Takamori, Sayaka
    Aoike, Suzuko
    Ishizaka, Kinya
    Kudo, Kohsuke
    MAGNETIC RESONANCE IMAGING, 2022, 87 : 32 - 37
  • [40] Rapid three-dimensional MR imaging: Method for tracking a bolus of contrast agent through the brain
    van Gelderen, P
    Grandin, C
    Petrella, JR
    Moonen, CTW
    RADIOLOGY, 2000, 216 (02) : 603 - 608