Three-dimensional Cardiac MR Imaging: Related Techniques and Clinical Applications

被引:16
作者
Amano, Yasuo [1 ,2 ]
Yanagisawa, Fumi [1 ,2 ]
Tachi, Masaki [2 ]
Asai, Kuniya [3 ]
Suzuki, Yasuyuki [4 ]
Hashimoto, Hidenobu [1 ,5 ]
Ishihara, Kiyohisa [6 ]
Kumita, Shinichiro [2 ]
机构
[1] Nihon Univ Hosp, Dept Radiol, Chiyoda Ku, 1-6 Kanda Surugadai, Tokyo 1018309, Japan
[2] Nippon Med Sch, Dept Radiol, Tokyo, Japan
[3] Nippon Med Sch, Dept Cardiol, Tokyo, Japan
[4] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[5] Toho Univ, Dept Cardiol, Omori Med Ctr, Tokyo, Japan
[6] Toshima Med Ctr, Tokyo, Japan
基金
日本学术振兴会;
关键词
three-dimensional imaging; cardiac magnetic resonance imaging; steady-state free precession; gadolinium; fast data acquisition; CARDIOVASCULAR MAGNETIC-RESONANCE; K-T SENSE; BREATH-HOLD; SPATIAL-RESOLUTION; MYOCARDIAL SCAR; HEART; ENHANCEMENT; FEASIBILITY; ANGIOGRAPHY; VIABILITY;
D O I
10.2463/mrms.rev.2016-0116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) cardiac magnetic resonance (MR) imaging has several advantages, including the easy coverage of the entire heart without misregistration, reduction of breath-holding times, and availability for postprocessing reconstruction. These advantages are associated with some techniques such as breath-hold or navigator gating and parallel imaging. However, the image quality of 3D cardiac MR images is compromised by the use of a shorter repetition time and parallel imaging. Thus, a steady-state free precession sequence, contrast agent administration, and presaturation pulses are used to maintain the image quality. In this review, we introduce the MR imaging techniques used in 3D cardiac MR imaging and demonstrate the typical 3D cardiac MR images, followed by discussion about their advantages and disadvantages.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 48 条
[1]   Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis -: Comparison of different approaches [J].
Abdel-Aty, H ;
Boyé, P ;
Zagrosek, A ;
Wassmuth, R ;
Kumar, A ;
Messroghli, D ;
Bock, P ;
Dietz, R ;
Friedrich, MG ;
Schulz-Menger, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) :1815-1822
[2]  
Alley MT, 1999, JMRI-J MAGN RESON IM, V9, P751, DOI 10.1002/(SICI)1522-2586(199905)9:5<751::AID-JMRI21>3.3.CO
[3]  
2-Z
[4]   Angiographic imaging with 2D RF pulses [J].
Alley, MT ;
Pauly, JM ;
Sommer, FG ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :260-267
[5]   Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: Comparison with two-dimensional cine imaging [J].
Amano, Yasuo ;
Suzuki, Yuriko ;
van Cauteren, Marc .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (01) :61-66
[6]   Fast 3-Breath-Hold 3-Dimensional Tagging Cardiac Magnetic Resonance in Patients with Hypertrophic Myocardial Diseases: A Feasibility Study [J].
Amano, Yasuo ;
Yamada, Fumi ;
Hashimoto, Hidenobu ;
Obara, Makoto ;
Asai, Kuniya ;
Kumita, Shinichiro .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[7]   Contrast-enhanced Steady-state Free Precession in the Assessment of Hypertrophic Obstructive Cardiomyopathy after Alcohol Septal Ablation [J].
Amano, Yasuo ;
Yamada, Fumi ;
Kitamura, Mitsunobu ;
Tachi, Masaki ;
Mine, Kumiko ;
Kumita, Shinichiro ;
Takayama, Morimasa .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (01) :130-136
[8]   Simultaneous Assessment of Myocardial Scar and Coronary Arteries Using Navigator-Gated 3-Dimensional Fat-Suppressed Delayed-Enhancement MRI at 3.0 T: A Technical Feasibility Study [J].
Amano, Yasuo ;
Kiriyama, Tomonari ;
Kobayashi, Yasuhiro ;
Tachi, Masaki ;
Matsumura, Yoshio ;
Kumita, Shinichiro .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) :72-76
[9]   Free-Breathing High-Spatial-Resolution Delayed Contrast-Enhanced Three-Dimensional Viability MR Imaging of the Myocardium at 3.0T: A Feasibility Study [J].
Amano, Yasuo ;
Matsumura, Yoshio ;
Kumita, Shinichiro .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) :1361-1367
[10]  
Brittain JH, 1995, MAGN RESON MED, V33, P2