Microdosimetry of the Auger electron emitting 123I radionuclide using Geant4-DNA simulations

被引:20
作者
Fourie, H. [1 ]
Newman, R. T. [1 ]
Slabbert, J. P. [2 ]
机构
[1] Univ Stellenbosch, Dept Phys, ZA-7602 Stellenbosch, South Africa
[2] iThemba LABS NRF, ZA-7129 Somerset West, South Africa
基金
新加坡国家研究基金会;
关键词
microdosimetry; auger electrons; Geant4-DNA; Monte Carlo; SINGLE-CELL DOSIMETRY; MONTE-CARLO; ABSORBED FRACTIONS; ENERGY DEPOSITION; LIQUID WATER; S-VALUES; RADIOIMMUNOTHERAPY; RADIOTOXICITY; SPECTRA; SPHERES;
D O I
10.1088/0031-9155/60/8/3333
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microdosimetric calculations of the Auger electron emitter I-123 were done in liquid water spheres using the Geant4 toolkit. The electron emission spectrum of 123I produced by Geant4 is presented. Energy deposition and corresponding S-values were calculated to investigate the influence of the sub-cellular localization of the Auger emitter. It was found that S-values calculated by the Geant4 toolkit are generally lower than the values calculated by other Monte Carlo codes for the I-123 radionuclide. The differences in the compared S-values are mainly due to the different particle emission spectra employed by the respective computational codes and emphasizes the influence of the spectra on dosimetry calculations.
引用
收藏
页码:3333 / 3346
页数:14
相关论文
共 39 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes [J].
Andre, T. ;
Morini, F. ;
Karamitros, M. ;
Delorme, R. ;
Le Loirec, C. ;
Campos, L. ;
Champion, C. ;
Groetz, J. -E. ;
Fromm, M. ;
Bordage, M. -C. ;
Perrot, Y. ;
Barberet, Ph ;
Bernal, M. A. ;
Brown, J. M. C. ;
Deleuze, M. S. ;
Francis, Z. ;
Ivanchenko, V. ;
Mascialino, B. ;
Zacharatou, C. ;
Bardies, M. ;
Incerti, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 319 :87-94
[3]  
[Anonymous], 2005, RAD ONCOLOGY PHYS HD
[4]  
[Anonymous], 2023, Rev 04 Release
[5]   DIELECTRIC-PROPERTIES OF MOUSE LYMPHOCYTES AND ERYTHROCYTES [J].
ASAMI, K ;
TAKAHASHI, Y ;
TAKASHIMA, S .
BIOCHIMICA ET BIOPHYSICA ACTA, 1989, 1010 (01) :49-55
[6]   Monte Carlo single-cell dosimetry of Auger-electron emitting radionuclides [J].
Bousis, C. ;
Emfietzoglou, D. ;
Hadjidoukas, P. ;
Nikjoo, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (09) :2555-2572
[7]   Calculations of absorbed fractions in small water spheres for low-energy monoenergetic electrons and the Auger-emitting radionuclides 123I and 125I [J].
Bousis, Christos ;
Emfietzoglou, Dimitris ;
Nikjoo, Hooshang .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2012, 88 (12) :916-921
[8]   Monte Carlo single-cell dosimetry of I-131, I-125 and I-123 for targeted radioimmunotherapy of B-cell lymphoma [J].
Bousis, Christos ;
Emfietzoglou, Dimitris ;
Nikjoo, Hooshang .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2012, 88 (12) :908-915
[9]   A MONTE-CARLO TREATMENT OF THE DECAY OF I-125 [J].
CHARLTON, DE ;
BOOZ, J .
RADIATION RESEARCH, 1981, 87 (01) :10-23
[10]  
Chiste V, 2014, I 123 TABLE RADIONUC