Effects of MRI protocols on brain FDG uptake in simultaneous PET/MR imaging

被引:2
作者
Wang, Jingjuan [1 ]
Yang, Hongwei [1 ]
Cui, Bixiao [1 ]
Shan, Baoci [2 ,3 ]
Lu, Jie [1 ,4 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol & Nucl Med, 45 Changchun St, Beijing 100053, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing, Peoples R China
[4] Key Lab Magnet Resonance Imaging & Brain Informat, Beijing, Peoples R China
关键词
PET/MR; Glucose metabolism; Physiological interference; MRI acoustic noise; Brain;
D O I
10.1007/s00259-022-05703-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the potential effects of MRI protocols on brain FDG uptake in simultaneous PET/MR imaging. Methods Seventy healthy subjects and ten patients with temporal lobe epilepsy were enrolled. Healthy subjects were divided to three groups to undergo different PET/MR scan protocols: "continuous MRI" with MRI stimulation presented during the whole scan, "late MRI" with MRI stimulation started after 40 min glucose uptake, and "no MRI" without MRI stimulation at all. Region-wise and voxel-wise differences in FDG uptake among the three protocols were compared. All epilepsy patients were scanned with the "continuous MRI" scan protocol. The effects of MRI protocol stimulation on pathological interpretation were evaluated. Results Highest global averaged metabolism was found in the normal dataset with continuous MRI scan protocol (P <0.05). Specifically, we observed higher FDG uptake in the primary auditory cortex, putamen, and lower FDG uptake in the occipital lobe and cerebellum during the "continuous MRI" scan protocol. However, MRI protocol stimulation after 40 min glucose uptake did not cause any significant differences in FDG uptake. Respectively compared to the normal dataset, patients with epilepsy showed consistent hypometabolism in the temporal lobe. Besides, significant metabolism changes in the primary auditory cortex, vermin, and occipital lobe were found in the "late MRI" protocol. Conclusion The effects of MRI protocol on brain FDG uptake were varied. The effects, including from other practical setting, were conspicuous for scans where MRI protocol started immediately after glucose uptake, but would dramatically decrease to negligible 40 min later. Hence, it would be necessary for pathology studies to collect data from a normal control group using the same scan protocol for unbiased evaluation.
引用
收藏
页码:2812 / 2820
页数:9
相关论文
共 50 条
[41]   Comparison of 18F-FDG-PET/CT and 18F-FDG-PET/MR imaging in oncology: a systematic review [J].
Amit Singnurkar ;
Raymond Poon ;
Ur Metser .
Annals of Nuclear Medicine, 2017, 31 :366-378
[42]   Structural and Molecular Imaging of Aging Brain A Focus on MR Imaging and PET Modalities [J].
Ghonim, Mohamed ;
Ghonim, Mohanad ;
Redden, Hyae Won Kim ;
Gharavi, Daniel ;
Mamidi, Ramya S. ;
Patel, Dev A. ;
Mirbod, Melika ;
Revheim, Mona-Elisabeth ;
Werner, Thomas J. ;
Newberg, Andrew B. ;
Alavi, Abass ;
Ayubcha, Cyrus .
PET CLINICS, 2025, 20 (01) :67-88
[43]   Comparison of 18F-FDG-PET/CT and 18F-FDG-PET/MR imaging in oncology: a systematic review [J].
Singnurkar, Amit ;
Poon, Raymond ;
Metser, Ur .
ANNALS OF NUCLEAR MEDICINE, 2017, 31 (05) :366-378
[44]   Effects of blood glucose level on FDG uptake by liver: a FDG-PET/CT study [J].
Kubota, Kazuo ;
Watanabe, Hiroshige ;
Murata, Yuji ;
Yukihiro, Masashi ;
Ito, Kimiteru ;
Morooka, Miyako ;
Minamimoto, Ryogo ;
Hori, Ai ;
Shibuya, Hitoshi .
NUCLEAR MEDICINE AND BIOLOGY, 2011, 38 (03) :347-351
[45]   MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: Phantom studya) [J].
Huang, Chuan ;
Ackerman, Jerome L. ;
Petibon, Yoann ;
Brady, Thomas J. ;
El Fakhri, Georges ;
Ouyang, Jinsong .
MEDICAL PHYSICS, 2014, 41 (04)
[46]   Modeling the acute pharmacological response to selective serotonin reuptake inhibitors in human brain using simultaneous PET/MR imaging [J].
Gryglewski, Gregor ;
Kloebl, Manfred ;
Berroteran-Infante, Neydher ;
Rischka, Lucas ;
Balber, Theresa ;
Vanicek, Thomas ;
Pichler, Verena ;
Kautzky, Alexander ;
Klebermass, Eva-Maria ;
Reed, Murray Bruce ;
Vraka, Chrysoula ;
Hienert, Marius ;
James, Gregory Miles ;
Silberbauer, Leo ;
Godbersen, Godber Mathis ;
Unterholzner, Jakob ;
Michenthaler, Paul ;
Hartenbach, Markus ;
Winkler-Pjrek, Edda ;
Wadsak, Wolfgang ;
Mitterhauser, Markus ;
Hahn, Andreas ;
Hacker, Marcus ;
Kasper, Siegfried ;
Lanzenberger, Rupert .
EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2019, 29 (06) :711-719
[47]   Impact of attenuation correction on clinical [18F]FDG brain PET in combined PET/MRI [J].
P. Werner ;
M. Rullmann ;
A. Bresch ;
S. Tiepolt ;
T. Jochimsen ;
D. Lobsien ;
M. L. Schroeter ;
O. Sabri ;
H. Barthel .
EJNMMI Research, 6
[48]   Impact of attenuation correction on clinical [18F]FDG brain PET in combined PET/MRI [J].
Werner, P. ;
Rullmann, M. ;
Bresch, A. ;
Tiepolt, S. ;
Jochimsen, T. ;
Lobsien, D. ;
Schroeter, M. L. ;
Sabri, O. ;
Barthel, H. .
EJNMMI RESEARCH, 2016, 6
[49]   FDG PET/MR in initial staging of sarcoma: Initial experience and comparison with conventional imaging [J].
Platzek, Ivan ;
Beuthien-Baumann, Bettina ;
Schramm, Georg ;
Maus, Jens ;
Laniado, Michael ;
Kotzerke, Joerg ;
van den Hoff, Joerg ;
Schuler, Markus .
CLINICAL IMAGING, 2017, 42 :126-132
[50]   Assessment of MR Compatibility of a PET Insert Developed for Simultaneous Multiparametric PET/MR Imaging on an Animal System Operating at 7 T [J].
Wehrl, Hans F. ;
Judenhofer, Martin S. ;
Thielscher, Axel ;
Martirosian, Petros ;
Schick, Fritz ;
Pichler, Bernd J. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) :269-279