Evaluation of performance of eccentric braced frame with friction damper

被引:0
作者
Amiri, J. Vaseghi [1 ]
Navayinia, B. [1 ]
Navaei, S. [1 ]
机构
[1] Babol Univ Technol, Dept Civil Engn, Babol Sar, Iran
关键词
friction damper (FD); slip load; nonlinear dynamic analysis; performance indices; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nonlinear dynamic analysis and evaluation of eccentric braced steel frames (EBF) equipped with friction damper (FD) is studied in this research. Previous studies about assessment of seismic performance of steel braced frame with FD have been generally limited to installing this device in confluence of cross in concentrically braced frame such chevron and x-bracing. Investigation is carried out with three types of steel frames namely 5, 10 and 15 storeys, representing the short, medium and high structures respectively in series of nonlinear dynamic analysis and 10 slip force values subjected to three different earthquake records. The proper place of FD, rather than providing them at all level is also studied in 15 storey frame. Four dimensionless indices namely roof displacement, base shear, dissipated energy and relative performance index (RPI) are determined in about 100 nonlinear dynamic analyses. Then average values of maximum roof displacement, base shear, energy dissipated and storey drift under three records for both EBF and EBF equipped with friction damper are obtained. The result indicates that FD reduces the response compared to EBF and is more efficient than EBF for taller storey frames.
引用
收藏
页码:717 / 732
页数:16
相关论文
共 50 条
[41]   Ductility reduction factor and collapse mechanism evaluation of a new steel knee braced frame [J].
Asghari, Abazar ;
Gandomi, Amir H. .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2016, 12 (02) :239-255
[42]   Dynamic Response of a Chevron Concentrically Braced Frame [J].
Okazaki, Taichiro ;
Lignos, Dimitrios G. ;
Hikino, Tsuyoshi ;
Kajiwara, Koichi .
JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (04) :515-525
[43]   A resilient column with angular friction damper for seismic performance upgrading of underground structures [J].
Wang, Yanchao ;
Chen, Qingjun ;
Zhao, Zhipeng ;
He, Zhiming .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 116
[44]   The Application of Genetic Algorithm in Seismic Performance Optimization of a Y-Eccentrically Braced Composite Frame [J].
Zhang, Wenxuan ;
Zhao, Yongfei ;
Wu, Zhenhao ;
Zhao, Jizhi ;
Wang, Shuke .
BUILDINGS, 2025, 15 (05)
[45]   Performance of steel frames with a new Friction Damper Device under earthquake excitation [J].
Mualla, IH ;
Belev, B .
ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 :1357-1364
[46]   Seismic performance evaluation of a multi-slit damper [J].
Naeem, Asad ;
Kim, Jinkoo .
ENGINEERING STRUCTURES, 2019, 189 :332-346
[47]   Successive collapse potential of eccentric braced frames in comparison with buckling-restrained braces in eccentric configurations [J].
Hosseini, Seyed Mohammad ;
Amiri, Gholamreza Ghodrati .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (02) :481-489
[48]   Successive collapse potential of eccentric braced frames in comparison with buckling-restrained braces in eccentric configurations [J].
Seyed Mohammad Hosseini ;
Gholamreza Ghodrati Amiri .
International Journal of Steel Structures, 2017, 17 :481-489
[49]   Seismic Performance Factors of Elliptic-Braced Frames with Rotational Friction Dampers through IDA [J].
Jouneghani, Habib Ghasemi ;
Nouri, Younes ;
Mortazavi, Mina ;
Haghollahi, Abbas ;
Memarzadeh, Parham .
PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2024, 29 (04)
[50]   Determination of Seismic Performance Factors for Buildings with Concentrically Braced Frame Systems under the Excitation of Near- and Far-fault Records [J].
Aftabiazar, Mehrdad ;
Shakeri, Kazem ;
Salehian, Afsaneh .
PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (04) :1144-1157