A prototype of radiation imaging detector using silicon strip sensors

被引:2
作者
Ryu, S. [1 ]
Hyun, H. J. [1 ]
Kah, D. H. [1 ]
Kang, H. D. [1 ]
Kim, H. J. [1 ]
Kim, Kyeryung [2 ]
Kim, Y. I. [1 ]
Park, H. [1 ]
Son, D. H. [1 ]
机构
[1] Kyungpook Natl Univ, Dept Phys, Taegu 702701, South Korea
[2] Korea Atom Energy Res Inst, Proton Engn Frontier Project, Taejon 305600, South Korea
基金
新加坡国家研究基金会;
关键词
silicon strip detector; proton imaging; phantom image; S/N ratio; cyclotron;
D O I
10.1016/j.nima.2008.03.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this work is to evaluate the performance of a strip sensor with a single photon counting data acquisition system based on VA1 readout chips to study the feasibility of a silicon microstrip detector for medical application. The sensor is an AC-coupled single-sided microstrip sensor and the active area of the sensor is 32.0 mm x 32.0 mm with a thickness of 380 mu m. The sensor has 64 readout strips with a pitch of 500 mu m. The sensor was biased at 45 V and the experiment was performed at room temperature. Two silicon strip sensors were mounted perpendicularly one another to get two-dimensional position information with a 5 mm space gap. Two low noise analog ASICs, VA1 chips, were used for signal readout of the strip sensor. The assembly of sensors and readout electronics was housed in an Al light-tight box. A CsI(Tl) scintillation crystal and a 2-in. photontultiplier tube were used to trigger signal events. The data acquisition system was based on a 64 MHz FADC and control softwares for the PC-Linux platform. Imaging tests were performed by using a lead phantom with a Sr-90 radioactive source and a 45 MeV proton beam at Korea Institute of Radiological and Medical Science in Seoul, respectively. Results of the SIN ratio measurement and phantom images are presented. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 140
页数:3
相关论文
共 7 条
  • [1] HYUN HJ, 2007, P 4 INT S RAD SAF DE
  • [2] *IDEAS, 1999, VA1 PRIME2 VERS 0 9
  • [3] KAH DH, 2007, P 4 INT S RAD SAF DE
  • [4] LUTZ G, 1999, SEMICONDUCTOR RAD DE, P110
  • [5] Park H, 2006, J KOREAN PHYS SOC, V49, P1401
  • [6] Signal-to-noise ratio measurement for silicon strip sensors with a proton beam
    Ryu, S.
    Bae, J. B.
    Hyun, H. J.
    Kah, D. H.
    Kim, Y. I.
    Kang, H. D.
    Kim, H. J.
    Park, H.
    Kim, Kyeryung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1477 - 1481
  • [7] YAO WM, 2006, J PHYS G, V33, P271