Part two: Analytical optimisation of a procedure for lead detection in milk by means of bismuth-modified screen-printed electrodes

被引:33
作者
Quintana, Josefina Calvo [1 ,2 ]
Arduini, Fabiana [1 ,2 ]
Amine, Aziz [3 ]
van Velzen, Kees [4 ]
Palleschi, Giuseppe [1 ,2 ]
Moscone, Danila [1 ,2 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Consorzio Interuniv Biostrutture & Biosistemi INB, I-00136 Rome, Italy
[3] Fac Sci & Tech, Mohammadia, Morocco
[4] Palm Instruments BV, NL-3992 BZ Houten, Netherlands
关键词
Lead; Bismuth; Milk; Sample pre-treatment; Stripping analysis; Screen-printed electrode; ANODIC-STRIPPING VOLTAMMETRY; FILM ELECTRODES; HEAVY-METALS; EXPOSURE; SAMPLES; ELECTROANALYSIS; COPPER; WATER; CELL;
D O I
10.1016/j.aca.2012.05.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the optimisation of a new analytical method for lead ion detection in milk: the electrochemical detection scheme is based on the method that was described in Part I [1]. It features the use of a disposable, environmentally friendly bismuth film electrode to replace the traditionally used (toxic) mercury one while here we report an arduous development of sample treatment so that the simple device can be applied as a screening tool in many settings. For this purpose, a milk pre-treatment procedure by means of wet digestion with HCl, HClO4, and H2O2 combined with an ultrasonic treatment was developed. The detection of lead ions in treated milk was then carried out using a disposable screen-printed electrode modified with Nafion (R) and an "in situ" bismuth film, with the analysis being performed in anodic stripping voltammetry mode. The analytical method developed allows the detection of milk contaminated with lead ions at a concentration of 20 mu g Kg(-1) (legal limit) and it can be proposed as a screening method for routine analysis of lead ions in milk with the advantage of employing inexpensive and portable instrumentation. Moreover, dedicated software supported by a portable instrument introduces procedures that are essential to avoid distortion from ambient lead contamination and also makes it possible for an unskilled operator to carry out each step of the analysis. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 26 条
  • [1] DETERMINATION OF CADMIUM, LEAD AND COPPER IN MILK AND MILK POWDER BY MEANS OF FLOW POTENTIOMETRIC STRIPPING ANALYSIS
    ALMESTRAND, L
    JAGNER, D
    RENMAN, L
    [J]. TALANTA, 1986, 33 (12) : 991 - 995
  • [2] [Anonymous], 1999, 97413 AOAC INT
  • [3] Fast, sensitive and cost-effective detection of nerve agents in the gas phase using a portable instrument and an electrochemical biosensor
    Arduini, Fabiana
    Amine, Aziz
    Moscone, Danila
    Ricci, Francesco
    Palleschi, Giuseppe
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1049 - 1057
  • [4] Bismuth-modified electrodes for lead detection
    Arduini, Fabiana
    Calvo, Josefina Quintana
    Amine, Aziz
    Palleschi, Giuseppe
    Moscone, Danila
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (11) : 1295 - 1304
  • [5] Electrocatalytic oxidation of thiocholine at chemically modified cobalt hexacyanoferrate screen-printed electrodes
    Arduini, Fabiana
    Cassisi, Alessio
    Amine, Aziz
    Ricci, Francesco
    Moscone, Danila
    Palleschi, Giuseppe
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 626 (1-2) : 66 - 74
  • [6] Development of a bio-electrochemical assay for AFB1 detection in olive oil
    Ben Rejeb, Ines
    Arduini, Fabiana
    Arvinte, Adina
    Amine, Aziz
    Gargouri, Mohamed
    Micheli, Laura
    Bala, Camelia
    Moscone, Danila
    Palleschi, Giuseppe
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 1962 - 1968
  • [7] Method validation for determination of arsenic, cadmium, chromium and lead in milk by means of dynamic reaction cell inductively coupled plasma mass spectrometry
    D'Ilio, S.
    Petrucci, F.
    D'Amato, M.
    Di Gregorio, M.
    Senofonte, O.
    Violante, N.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 624 (01) : 59 - 67
  • [8] Ultrasound-assisted preparation of liquid samples
    de Castro, M. D. Luque
    Priego-Capote, F.
    [J]. TALANTA, 2007, 72 (02) : 321 - 334
  • [9] Bismuth-film electrodes: recent developments and potentialities for electroanalysis
    Economou, A
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) : 334 - 340
  • [10] Effects of lead on the endocrine system in lead smelter workers
    Erfurth, EM
    Gerhardsson, L
    Nilsson, A
    Rylander, L
    Schütz, A
    Skerfving, S
    Börjesson, J
    [J]. ARCHIVES OF ENVIRONMENTAL HEALTH, 2001, 56 (05): : 449 - 455