Removal of Procion Red MX-5B dye from wastewater by conductive-diamond electrochemical oxidation

被引:134
作者
Cotillas, Salvador [1 ]
Llanos, Javier [2 ]
Canizares, Pablo [2 ]
Clematis, Davide [3 ]
Cerisola, Giacomo [3 ]
Rodrigo, Manuel A. [2 ]
Panizza, Marco [3 ]
机构
[1] Univ Castilla La Mancha, Sch Ind Engn, Chem Engn Dept, Albacete 02071, Spain
[2] Univ Castilla La Mancha, Chem Engn Dept, Fac Chem Sci & Technol, Ciudad Real 13005, Spain
[3] Univ Genoa, Dept Civil Chem & Environm Engn, Ple JF Kennedy 1, I-16129 Genoa, Italy
关键词
Electrolysis; Procion red dye; Hydroxyl radical; BDD; DSA; ANODE MATERIAL; ELECTROLYSIS; DEGRADATION; REMEDIATION; DISINFECTION; TECHNOLOGIES; WASTEWATERS; POLLUTANTS; ELECTRODES; EFFLUENT;
D O I
10.1016/j.electacta.2018.01.052
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, the removal of Procion Red MX-5B dye by electrochemical oxidation with boron doped diamond (BDD) anodes was investigated. The impact of current density, flow rate, initial pH, and supporting electrolyte was evaluated on dye and organic matter removal. Furthermore, the use of dimensionally stable anodes (DSA) was tested to evaluate process performance. Results show that after 240 min, it is possible to achieve full dye and COD (Chemical Oxygen Demand) removal, regardless of applied current density. This is due to the generation of powerful oxidants - i.e. hydroxyl radicals and peroxodisulfate-, which attack the organic matter in the wastewater, promoting its complete degradation. However, process efficiency increases when using lower current densities (10 mA cm(-2)): electric charges of about 5 Ah dm(-3) are sufficient to fully remove both dye and COD, while charges higher than 15 Ah dm(-3) are required when working at higher current densities (> 30 mA cm(-2)). This fact is related to the production of large amounts of hydroxyl radicals, which are wasted in other reactions at higher current densities. On the other hand, higher flow rates (300 dm(3) h(-1)) promote Procion Red MX-5B and organic matter degradation, due to improved mass transfer within the system. Regarding the impact of initial pH on dye removal, no significant differences were observed. Conversely, COD is clearly affected by this parameter: it is only possible to fully remove the organic matter when working at natural pH. Finally, with DSA anodes, higher dye removal efficiencies are attained than with BDD electrodes, when 100 mg dm(-3) chlorides are added to the supporting electrolyte. Likewise, higher chloride concentration (100-1000 mg dm(-3)) was observed to enhance process efficiency when using DSA as anode material. However, during electrolysis with both BDD and DSA, chloride ions in the supporting electrolyte promote the production of intermediate organochlorinated compounds. Therefore, under these conditions, no full organic matter removal can be achieved, regardless of the anode material employed. (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 47 条
  • [1] Baglio V, 2008, J NEW MAT ELECTR SYS, V11, P105
  • [2] The occurrence of perchlorate during drinking water electrolysis using BDD anodes
    Bergmann, M. E. Henry
    Rollin, Johanna
    Iourtchouk, Tatiana
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (07) : 2102 - 2107
  • [3] Aniline degradation by Electro-Fenton® and peroxi-coagulation processes using a flow reactor for wastewater treatment
    Brillas, E
    Casado, J
    [J]. CHEMOSPHERE, 2002, 47 (03) : 241 - 248
  • [4] Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods. An updated review
    Brillas, Enric
    Martinez-Huitle, Carlos A.
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 2015, 166 : 603 - 643
  • [5] Electrochemical treatment of the effluent of a fine chemical manufacturing plant
    Canizares, P.
    Paz, R.
    Lobato, J.
    Saez, C.
    Rodrigo, M. A.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2006, 138 (01) : 173 - 181
  • [6] Congo red adsorption from aqueous solutions by using chitosan hydrogel beads impregnated with nonionic or anionic surfactant
    Chatterjee, Sudipta
    Lee, Dae S.
    Lee, Min W.
    Woo, Seung H.
    [J]. BIORESOURCE TECHNOLOGY, 2009, 100 (17) : 3862 - 3868
  • [7] Electrochemical technologies in wastewater treatment
    Chen, GH
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) : 11 - 41
  • [8] Synergistic integration of sonochemical and electrochemical disinfection with DSA anodes
    Cotillas, Salvador
    Llanos, Javier
    Castro-Rios, Katherin
    Taborda-Ocampo, Gonzalo
    Rodrigo, Manuel A.
    Canizares, Pablo
    [J]. CHEMOSPHERE, 2016, 163 : 562 - 568
  • [9] Electrolytic and electro-irradiated processes with diamond anodes for the oxidation of persistent pollutants and disinfection of urban treated wastewater
    Cotillas, Salvador
    Martin de Vidales, Maria J.
    Llanos, Javier
    Saez, Cristina
    Canizares, Pablo
    Rodrigo, Manuel A.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2016, 319 : 93 - 101
  • [10] Electrochemical Synthesis of Peroxyacetic Acid Using Conductive Diamond Electrodes
    Cotillas, Salvador
    Sanchez-Carretero, Ana
    Canizares, Pablo
    Saez, Cristina
    Andres Rodrigo, Manuel
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (18) : 10889 - 10893