Coagulation factor abnormalities related to discordance between anti-factor Xa and activated partial, thromboplastin time in patients supported with continuous-flow left ventricular assist devices

被引:17
作者
Adatya, Sirtaz [1 ]
Sunny, Roy [2 ]
Fitzpatrick, Megan J. [3 ]
Colvin, Monica [4 ]
Thennapan, Thennapan [2 ]
John, Ranjit [5 ]
Zantek, Nicole Dodge [6 ]
Pritzker, Marc [2 ]
Eckman, Peter [7 ]
Uriel, Nir [1 ]
机构
[1] Univ Chicago, Dept Med, Div Cardiol, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Minnesota, Dept Med, Cardiovasc Div, Box 736 UMHC, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[4] Div Cardiol, Minneapolis, MN USA
[5] Dept Surg, Div Cardiothorac Surg, Minneapolis, MN USA
[6] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN 55455 USA
[7] Minneapolis Heart Inst, Dept Med, Div Cardiol, Minneapolis, MN USA
关键词
ventricular assist device; heparin; anti-factor Xa; activated partial thromboplastic time; PTT; coagulation factors; device thrombosis; hemolysis; bleeding; anti-coagulation; warfarin; MONITORING UNFRACTIONATED HEPARIN; VON-WILLEBRAND SYNDROME; FACTOR-VIII LEVELS; FACTOR-XII; THERAPEUTIC RANGE; HEART; PREVALENCE; THROMBOSIS; REAGENTS; RISK;
D O I
10.1016/j.healun.2016.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: High levels of discordance between activated partial thromboplastin time (aPTT) and anti-factor Xa (anti-FXa) have been reported in patients with continuous-flow left ventricular assist devices (CF-LVADs). We sought to determine the biochemical basis for discordance by simultaneous measurement of coagulation factors with aPTT and anti-FXa. METHODS: Consecutive CF-LVAD patients admitted for intravenous unfractionated heparin (IV-UFH) therapy were studied. IV-UFH was monitored based on an anti-FXa. International normalized ratio (INR), aPTT, lactate dehydrogenase, and coagulation factors II, V, VII, VIII, IX, X, XI, and XII were measured simultaneously with anti-FXa. RESULTS: The discordance rate between anti-FXa and aPTT was 74.7% overall (568 of 760 samples from 62 patients). In samples in which coagulation factors were simultaneously measured, the discordance rate was 66% (49 of 74 samples from 52 patients). In patients with INR <= 1.0 the discordance level was 31.8% vs 82.7% with INR > 1.8. No difference was observed in the rate of discordance between samples with low vs normal vitamin K-dependent factors (65.9% vs 64.7%, p = 0.99). Low factor XII was found in 15%; of these, 90.9% exhibited anti-FXa/aPTT discordance. Low factor V was found in 8.2%, and all were discordant. Factor VIII was elevated in 97% of samples, and 65.7% were discordant. CONCLUSIONS: In addition to the effects of warfarin administration on aPTT, the influence of other factors, such as low factor XII or V, may contribute to the discordance between aPTT values and anti-FXa. Coagulation factor levels may assist in individualization of anti-coagulation targets while patients implanted with CF-LVADs are on IV-UFH. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:1311 / 1320
页数:10
相关论文
共 39 条
  • [31] National trends and outcomes in device-related thromboembolic complications and malfunction among heart transplant candidates supported with continuous-flow left ventricular assist devices in the United States
    Wever-Pinzon, Omar
    Naka, Yoshifumi
    Garan, Arthur R.
    Takeda, Koji
    Pan, Stephen
    Takayama, Hiroo
    Mancini, Donna M.
    Colombo, Paolo
    Topkara, Veli K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (07) : 884 - 892
  • [32] Platelet activation is a preoperative risk factor for the development of thromboembolic complications in patients with continuous-flow left ventricular assist device
    Consolo, Filippo
    Sferrazza, Giulia
    Motolone, Giulia
    Contri, Rachele
    Valerio, Lorenzo
    Lembo, Rosalba
    Pozzi, Loris
    Della Valle, Patrizia
    De Bonis, Michele
    Zangrillo, Alberto
    Fiore, Gianfranco B.
    Redaelli, Alberto
    Slepian, Marvin J.
    Pappalardo, Federico
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 (04) : 792 - 800
  • [33] Loss of pulsatility with continuous-flow left ventricular assist devices and the significance of the arterial endothelium in von-Willebrand factor production and degradation
    Giridharan, Guruprasad A.
    Berg, Ian C.
    Ismail, Esraa
    Nguyen, Khanh T.
    Hecking, Jana
    Kirklin, James K.
    Cheng, Xuanhong
    Sethu, Palaniappan
    ARTIFICIAL ORGANS, 2023, 47 (04) : 640 - 648
  • [34] The association between novel clinical factors and gastrointestinal bleeding among patients supported with continuous-flow left ventricular assist device therapy
    Thohan, Vinay
    Shi, Yang
    Rappelt, Matthew
    Yousefzai, Rayan
    Sulemanjee, Nasir Z.
    Hastings, Thomas E.
    Cheema, Omar M.
    Downey, Frank
    Crouch, John D.
    JOURNAL OF CARDIAC SURGERY, 2019, 34 (06) : 453 - 462
  • [35] Discordant High Activated Partial Thromboplastin Time Relative to Anti-Xa Values in Hospitalized Patients is an Independent Risk Factor for Increased 30-day Mortality
    Jin, Jing
    Gummidipundi, Santosh
    Hsu, Joe
    Sharifi, Husham
    Boothroyd, Derek
    Krishnan, Anandi
    Zehnder, James L.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2024,
  • [36] Left Ventricular Decompression During Speed Optimization Ramps in Patients Supported by Continuous-Flow Left Ventricular Assist Devices: Device-Specific Performance Characteristics and Impact on Diagnostic Algorithms
    Uriel, Nir
    Levin, Allison P.
    Sayer, Gabriel T.
    Mody, Kanika P.
    Thomas, Sunu S.
    Adatya, Sirtaz
    Yuzefpolskaya, Melana
    Garan, Arthur R.
    Breskin, Alexander
    Takayama, Hiroo
    Colombo, Paulo C.
    Naka, Yoshifumi
    Burkhoff, Daniel
    Jorde, Ulrich P.
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : 785 - 791
  • [37] Platelet glycoprotein IBα ectodomain shedding and non-surgical bleeding in heart failure patients supported by continuous-flow left ventricular assist devices
    Hu, Jingping
    Mondal, Nandan K.
    Sorensen, Erik N.
    Cai, Ling
    Fang, Hong-Bin
    Griffith, Bartley P.
    Wu, Zhongjun J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) : 71 - 79
  • [38] Medical Management of Pump-Related Thrombosis in Patients with Continuous-Flow Left Ventricular Assist Devices: A Systematic Review and Meta-Analysis
    Dang, Geetanjali
    Epperla, Narendranath
    Muppidi, Vijayadershan
    Sahr, Natasha
    Pan, Amy
    Simpson, Pippa
    Kreuziger, Lisa Baumann
    ASAIO JOURNAL, 2017, 63 (04) : 373 - 385
  • [39] Anti-Factor-Xa and Activated Partial Thromboplastin Time Concordance and Outcomes in Adults Undergoing Extracorporeal Membrane Oxygenation: A Secondary Analysis of the Pilot Low-Dose Heparin in Critically Ill Patients Undergoing Extracorporeal Membrane Oxygenation Randomized Trial
    Aubron, Cecile
    Chapalain, Xavier
    Bailey, Michael
    Board, Jasmin
    Buhr, Heidi
    Cartwright, Bruce
    Dennis, Mark
    Hodgson, Carol
    Forrest, Paul
    Mcilroy, David
    Murphy, Deirdre
    Murray, Lynne
    Pellegrino, Vincent
    Pilcher, David
    Sheldrake, Jayne
    Tran, Huyen
    Vallance, Shirley
    Cooper, D. James
    Mcquilten, Zoe
    CRITICAL CARE EXPLORATIONS, 2023, 5 (11) : E0999