Coagulation factor abnormalities related to discordance between anti-factor Xa and activated partial, thromboplastin time in patients supported with continuous-flow left ventricular assist devices

被引:17
|
作者
Adatya, Sirtaz [1 ]
Sunny, Roy [2 ]
Fitzpatrick, Megan J. [3 ]
Colvin, Monica [4 ]
Thennapan, Thennapan [2 ]
John, Ranjit [5 ]
Zantek, Nicole Dodge [6 ]
Pritzker, Marc [2 ]
Eckman, Peter [7 ]
Uriel, Nir [1 ]
机构
[1] Univ Chicago, Dept Med, Div Cardiol, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Minnesota, Dept Med, Cardiovasc Div, Box 736 UMHC, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[4] Div Cardiol, Minneapolis, MN USA
[5] Dept Surg, Div Cardiothorac Surg, Minneapolis, MN USA
[6] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN 55455 USA
[7] Minneapolis Heart Inst, Dept Med, Div Cardiol, Minneapolis, MN USA
关键词
ventricular assist device; heparin; anti-factor Xa; activated partial thromboplastic time; PTT; coagulation factors; device thrombosis; hemolysis; bleeding; anti-coagulation; warfarin; MONITORING UNFRACTIONATED HEPARIN; VON-WILLEBRAND SYNDROME; FACTOR-VIII LEVELS; FACTOR-XII; THERAPEUTIC RANGE; HEART; PREVALENCE; THROMBOSIS; REAGENTS; RISK;
D O I
10.1016/j.healun.2016.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: High levels of discordance between activated partial thromboplastin time (aPTT) and anti-factor Xa (anti-FXa) have been reported in patients with continuous-flow left ventricular assist devices (CF-LVADs). We sought to determine the biochemical basis for discordance by simultaneous measurement of coagulation factors with aPTT and anti-FXa. METHODS: Consecutive CF-LVAD patients admitted for intravenous unfractionated heparin (IV-UFH) therapy were studied. IV-UFH was monitored based on an anti-FXa. International normalized ratio (INR), aPTT, lactate dehydrogenase, and coagulation factors II, V, VII, VIII, IX, X, XI, and XII were measured simultaneously with anti-FXa. RESULTS: The discordance rate between anti-FXa and aPTT was 74.7% overall (568 of 760 samples from 62 patients). In samples in which coagulation factors were simultaneously measured, the discordance rate was 66% (49 of 74 samples from 52 patients). In patients with INR <= 1.0 the discordance level was 31.8% vs 82.7% with INR > 1.8. No difference was observed in the rate of discordance between samples with low vs normal vitamin K-dependent factors (65.9% vs 64.7%, p = 0.99). Low factor XII was found in 15%; of these, 90.9% exhibited anti-FXa/aPTT discordance. Low factor V was found in 8.2%, and all were discordant. Factor VIII was elevated in 97% of samples, and 65.7% were discordant. CONCLUSIONS: In addition to the effects of warfarin administration on aPTT, the influence of other factors, such as low factor XII or V, may contribute to the discordance between aPTT values and anti-FXa. Coagulation factor levels may assist in individualization of anti-coagulation targets while patients implanted with CF-LVADs are on IV-UFH. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:1311 / 1320
页数:10
相关论文
共 39 条
  • [21] Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time: reply to a rebuttal
    Cuker, A.
    Cines, D. B.
    Pollak, E. S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (12) : 2158 - 2159
  • [23] Pre-Operative Right Ventricular Dysfunction Is Associated With Gastrointestinal Bleeding in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Sparrow, Christopher T.
    Nassif, Michael E.
    Raymer, David S.
    Novak, Eric
    LaRue, Shane J.
    Schilling, Joel D.
    JACC-HEART FAILURE, 2015, 3 (12) : 956 - 964
  • [24] Anti-Factor Xa Assay Is a Superior Correlate of Heparin Dose Than Activated Partial Thromboplastin Time or Activated Clotting Time in Pediatric Extracorporeal Membrane Oxygenation
    Liveris, Anna
    Bello, Ricardo A.
    Friedmann, Patricia
    Duffy, Melissa A.
    Manwani, Deepa
    Killinger, James S.
    Rodriquez, Daniel
    Weinstein, Samuel
    PEDIATRIC CRITICAL CARE MEDICINE, 2014, 15 (02) : E72 - E79
  • [25] Variation in coagulation factor activity levels cause discrepancies between activated partial thromboplastin time and anti-Xa activity for heparin monitoring: a retrospective observational study
    Saito, Tomoyo
    Hayakawa, Mineji
    Kumano, Osamu
    Honma, Yoshinori
    Murashita, Mone
    Kato, Jun
    Fukui, Syouki
    Takahashi, Masaki
    Takahashi, Yuki
    Tsuchida, Takumi
    Mizugaki, Asumi
    Takauji, Shuhei
    Hayamizu, Mariko
    Yoshida, Tomonao
    Katabami, Kenichi
    Wada, Takeshi
    Maekawa, Kunihiko
    JOURNAL OF INTENSIVE CARE, 2023, 11 (01)
  • [26] Device-related epistaxis risk: continuous-flow left ventricular assist device-supported patients
    Koycu, Alper
    Vural, Omer
    Bahcecitapar, Melike
    Jafarov, Sabuhi
    Beyazpinar, Gulfem
    Beyazpinar, Deniz Sarp
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (10) : 2767 - 2773
  • [27] Retrospective cohort study comparing activated partial thromboplastin time versus anti-factor Xa activity nomograms for therapeutic unfractionated heparin monitoring in pediatrics
    Trucco, M.
    Lehmann, C. U.
    Mollenkopf, N.
    Streiff, M. B.
    Takemoto, C. M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (05) : 788 - 794
  • [28] Tumor necrosis factor-α levels and non-surgical bleeding in continuous-flow left ventricular assist devices
    Tabit, Corey E.
    Coplan, Mitchell J.
    Chen, Phetcharat
    Jeevanandam, Valluvan
    Uriel, Nir
    Liao, James K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (01) : 107 - 115
  • [29] Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device
    Jung, Mette H.
    Hassager, Christian
    Balling, Louise
    Russell, Stuart D.
    Boesgaard, Soeren
    Gustafsson, Finn
    ASAIO JOURNAL, 2015, 61 (03) : 307 - 312
  • [30] Variation in coagulation factor activity levels cause discrepancies between activated partial thromboplastin time and anti-Xa activity for heparin monitoring: a retrospective observational study
    Tomoyo Saito
    Mineji Hayakawa
    Osamu Kumano
    Yoshinori Honma
    Mone Murashita
    Jun Kato
    Syouki Fukui
    Masaki Takahashi
    Yuki Takahashi
    Takumi Tsuchida
    Asumi Mizugaki
    Shuhei Takauji
    Mariko Hayamizu
    Tomonao Yoshida
    Kenichi Katabami
    Takeshi Wada
    Kunihiko Maekawa
    Journal of Intensive Care, 11