Coagulation factor abnormalities related to discordance between anti-factor Xa and activated partial, thromboplastin time in patients supported with continuous-flow left ventricular assist devices

被引:17
|
作者
Adatya, Sirtaz [1 ]
Sunny, Roy [2 ]
Fitzpatrick, Megan J. [3 ]
Colvin, Monica [4 ]
Thennapan, Thennapan [2 ]
John, Ranjit [5 ]
Zantek, Nicole Dodge [6 ]
Pritzker, Marc [2 ]
Eckman, Peter [7 ]
Uriel, Nir [1 ]
机构
[1] Univ Chicago, Dept Med, Div Cardiol, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Minnesota, Dept Med, Cardiovasc Div, Box 736 UMHC, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[4] Div Cardiol, Minneapolis, MN USA
[5] Dept Surg, Div Cardiothorac Surg, Minneapolis, MN USA
[6] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN 55455 USA
[7] Minneapolis Heart Inst, Dept Med, Div Cardiol, Minneapolis, MN USA
关键词
ventricular assist device; heparin; anti-factor Xa; activated partial thromboplastic time; PTT; coagulation factors; device thrombosis; hemolysis; bleeding; anti-coagulation; warfarin; MONITORING UNFRACTIONATED HEPARIN; VON-WILLEBRAND SYNDROME; FACTOR-VIII LEVELS; FACTOR-XII; THERAPEUTIC RANGE; HEART; PREVALENCE; THROMBOSIS; REAGENTS; RISK;
D O I
10.1016/j.healun.2016.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: High levels of discordance between activated partial thromboplastin time (aPTT) and anti-factor Xa (anti-FXa) have been reported in patients with continuous-flow left ventricular assist devices (CF-LVADs). We sought to determine the biochemical basis for discordance by simultaneous measurement of coagulation factors with aPTT and anti-FXa. METHODS: Consecutive CF-LVAD patients admitted for intravenous unfractionated heparin (IV-UFH) therapy were studied. IV-UFH was monitored based on an anti-FXa. International normalized ratio (INR), aPTT, lactate dehydrogenase, and coagulation factors II, V, VII, VIII, IX, X, XI, and XII were measured simultaneously with anti-FXa. RESULTS: The discordance rate between anti-FXa and aPTT was 74.7% overall (568 of 760 samples from 62 patients). In samples in which coagulation factors were simultaneously measured, the discordance rate was 66% (49 of 74 samples from 52 patients). In patients with INR <= 1.0 the discordance level was 31.8% vs 82.7% with INR > 1.8. No difference was observed in the rate of discordance between samples with low vs normal vitamin K-dependent factors (65.9% vs 64.7%, p = 0.99). Low factor XII was found in 15%; of these, 90.9% exhibited anti-FXa/aPTT discordance. Low factor V was found in 8.2%, and all were discordant. Factor VIII was elevated in 97% of samples, and 65.7% were discordant. CONCLUSIONS: In addition to the effects of warfarin administration on aPTT, the influence of other factors, such as low factor XII or V, may contribute to the discordance between aPTT values and anti-FXa. Coagulation factor levels may assist in individualization of anti-coagulation targets while patients implanted with CF-LVADs are on IV-UFH. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:1311 / 1320
页数:10
相关论文
共 39 条
  • [11] Impact of time off anticoagulation in patients with continuous-flow left ventricular assist devices
    Christian A. Inchaustegui
    Ashley Patel
    Harveen K. Lamba
    Andrew Brown
    Justin Arunthamakun
    Kevin Ting
    Subhasis Chatterjee
    Ajith P. Nair
    Joggy K. George
    Alexis E. Shafii
    Kenneth K. Liao
    Andrew B. Civitello
    Journal of Artificial Organs, 2023, 26 : 275 - 286
  • [12] Performance of Anti-Factor Xa Versus Activated Partial Thromboplastin Time for Heparin Monitoring Using Multiple Nomograms
    Whitman-Purves, Emily
    Coons, James C.
    Miller, Taylor
    DiNella, Jeannine V.
    Althouse, Andrew
    Schmidhofer, Mark
    Smith, Roy E.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2018, 24 (02) : 310 - 316
  • [13] Anti-Factor Xa and Activated Partial Thromboplastin Time Measurements for Heparin Monitoring in Mechanical Circulatory Support
    Adatya, Sirtaz
    Uriel, Nir
    Yarmohammadi, Hirad
    Holley, Christopher T.
    Feng, Amy
    Roy, Samit S.
    Reding, Mark T.
    John, Ranjit
    Eckman, Peter
    Zantek, Nicole D.
    JACC-HEART FAILURE, 2015, 3 (04) : 314 - 322
  • [14] Activated Partial Thromboplastin Time Versus Anti-Factor Xa Monitoring of Heparin Anticoagulation in Adult Venoarterial Extracorporeal Membrane Oxygenation Patients
    Kulig, Caitlin E.
    Schomer, Kendra J.
    Black, Hugh B.
    Dager, William E.
    ASAIO JOURNAL, 2021, 67 (04) : 411 - 415
  • [15] Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left ventricular assist devices
    Fried, Justin
    Levin, Allison P.
    Mody, Kanika M.
    Garan, Arthur R.
    Yuzefpolsakaya, Melana
    Takayama, Hiroo
    Diuguid, David L.
    Naka, Yoshifumi
    Jorde, Ulrich
    Uriel, Nir
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (11) : 1119 - 1125
  • [16] Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices
    Frazier, O. H.
    Baldwin, Andrew C. W.
    Demirozu, Zumrut T.
    Segura, Ana Maria
    Hernandez, Ruben
    Taegtmeyer, Heinrich
    Mallidi, Hari
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06) : 766 - 772
  • [17] Concordance Between Active Partial Thromboplastin Time and Anti-Factor Xa Assays in Neurocritically Ill Patients Receiving Subcutaneous Heparin Prophylaxis
    Shinn, Grace
    Berger, Karen
    Roh, David
    Doyle, Kevin
    Boehme, Amelia K.
    Connolly, Edward Sander
    Park, Soojin
    Agarwal, Sachin
    Claassen, Jan
    Der-Nigoghossian, Caroline
    NEUROHOSPITALIST, 2023, 13 (03) : 221 - 227
  • [18] Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time: a rebuttal
    Kitchen, S.
    Preston, F. E.
    Jennings, I.
    Kitchen, D. P.
    Woods, T. A. L.
    Walker, I.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (12) : 2157 - 2158
  • [19] Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices
    Dionizovik-Dimanovski, Marija
    Levin, Allison P.
    Fried, Justin
    Mody, Kanika P.
    Simonich, Erica
    Garan, Arthur Reshad
    Yuzefpolskaya, Melana
    Takayama, Hiroo
    Naka, Yoshifumi
    Colombo, Paolo C.
    Kalesan, Bindu
    Uriel, Nir
    Jorde, Ulrich P.
    ASAIO JOURNAL, 2015, 61 (04) : 386 - 390
  • [20] Prevention and Treatment of Thrombotic and Hemorrhagic Complications in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Loyaga-Rendon R.Y.
    Jani M.
    Fermin D.
    McDermott J.K.
    Vancamp D.
    Lee S.
    Current Heart Failure Reports, 2017, 14 (6) : 465 - 477