Coagulation factor abnormalities related to discordance between anti-factor Xa and activated partial, thromboplastin time in patients supported with continuous-flow left ventricular assist devices

被引:17
|
作者
Adatya, Sirtaz [1 ]
Sunny, Roy [2 ]
Fitzpatrick, Megan J. [3 ]
Colvin, Monica [4 ]
Thennapan, Thennapan [2 ]
John, Ranjit [5 ]
Zantek, Nicole Dodge [6 ]
Pritzker, Marc [2 ]
Eckman, Peter [7 ]
Uriel, Nir [1 ]
机构
[1] Univ Chicago, Dept Med, Div Cardiol, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Minnesota, Dept Med, Cardiovasc Div, Box 736 UMHC, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Minneapolis, MN 55455 USA
[4] Div Cardiol, Minneapolis, MN USA
[5] Dept Surg, Div Cardiothorac Surg, Minneapolis, MN USA
[6] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN 55455 USA
[7] Minneapolis Heart Inst, Dept Med, Div Cardiol, Minneapolis, MN USA
关键词
ventricular assist device; heparin; anti-factor Xa; activated partial thromboplastic time; PTT; coagulation factors; device thrombosis; hemolysis; bleeding; anti-coagulation; warfarin; MONITORING UNFRACTIONATED HEPARIN; VON-WILLEBRAND SYNDROME; FACTOR-VIII LEVELS; FACTOR-XII; THERAPEUTIC RANGE; HEART; PREVALENCE; THROMBOSIS; REAGENTS; RISK;
D O I
10.1016/j.healun.2016.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: High levels of discordance between activated partial thromboplastin time (aPTT) and anti-factor Xa (anti-FXa) have been reported in patients with continuous-flow left ventricular assist devices (CF-LVADs). We sought to determine the biochemical basis for discordance by simultaneous measurement of coagulation factors with aPTT and anti-FXa. METHODS: Consecutive CF-LVAD patients admitted for intravenous unfractionated heparin (IV-UFH) therapy were studied. IV-UFH was monitored based on an anti-FXa. International normalized ratio (INR), aPTT, lactate dehydrogenase, and coagulation factors II, V, VII, VIII, IX, X, XI, and XII were measured simultaneously with anti-FXa. RESULTS: The discordance rate between anti-FXa and aPTT was 74.7% overall (568 of 760 samples from 62 patients). In samples in which coagulation factors were simultaneously measured, the discordance rate was 66% (49 of 74 samples from 52 patients). In patients with INR <= 1.0 the discordance level was 31.8% vs 82.7% with INR > 1.8. No difference was observed in the rate of discordance between samples with low vs normal vitamin K-dependent factors (65.9% vs 64.7%, p = 0.99). Low factor XII was found in 15%; of these, 90.9% exhibited anti-FXa/aPTT discordance. Low factor V was found in 8.2%, and all were discordant. Factor VIII was elevated in 97% of samples, and 65.7% were discordant. CONCLUSIONS: In addition to the effects of warfarin administration on aPTT, the influence of other factors, such as low factor XII or V, may contribute to the discordance between aPTT values and anti-FXa. Coagulation factor levels may assist in individualization of anti-coagulation targets while patients implanted with CF-LVADs are on IV-UFH. (C) 2016 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:1311 / 1320
页数:10
相关论文
共 39 条
  • [1] Basis for Biochemical Discordance Between Activated Partial Thromboplastin Time and Anti-factor Xa in Patients with Continuous Flow Left Ventricular Assist Device on Unfractionated Heparin Infusion
    Yarmohammadi, Hirad
    Feng, Amy J.
    Alraies, Chadi M.
    Thenappan, Thenappan
    Colvin, Monica
    John, Ranjit
    Eckman, Peter
    Pritzker, Marc
    Adatya, Sirtaz
    CIRCULATION, 2014, 130
  • [2] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Parikh, Vishal Y.
    Parikh, Umang M.
    Moctezuma-Ramirez, Angel
    Lamba, Harveen K.
    George, Joggy K.
    Fedson, Savitri
    Nair, Ajith P.
    Frazier, O. H.
    Delgado, Reynolds M.
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (11) : 1278 - 1284
  • [3] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Vishal Y. Parikh
    Umang M. Parikh
    Angel Moctezuma-Ramirez
    Harveen K. Lamba
    Joggy K. George
    Savitri Fedson
    Ajith P. Nair
    O. H.  Frazier
    Reynolds M. Delgado
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 1278 - 1284
  • [4] Anti-factor Xa activity, prothrombin time, and activated partial thromboplastin time in patients treated with factor Xa inhibitors
    Ono, Ryohei
    Nishimura, Kazutaka
    Takahashi, Hidehisa
    Hori, Yasuhiko
    Fukushima, Kenichi
    Kobayashi, Yoshio
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2023, 396 (02) : 323 - 336
  • [5] Impact of time off anticoagulation in patients with continuous-flow left ventricular assist devices
    Inchaustegui, Christian A.
    Patel, Ashley
    Lamba, Harveen K.
    Brown, Andrew
    Arunthamakun, Justin
    Ting, Kevin
    Chatterjee, Subhasis
    Nair, Ajith P.
    George, Joggy K.
    Shafii, Alexis E.
    Liao, Kenneth K.
    Civitello, Andrew B.
    JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (04) : 275 - 286
  • [6] Anti-factor Xa and activated partial thromboplastin time strategies for unfractionated heparin dosing after HeartMate 3 left ventricular assist device implantation
    Feng, Iris
    Kurlansky, Paul A.
    Powley, Tanner R.
    Hynds, Melissa A.
    Yang, Christine G.
    Eisenberger, Andrew
    Hastie, Jonathan M.
    Sutherland, Lauren D.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Sayer, Gabriel T.
    Uriel, Nir Y.
    Naka, Yoshifumi
    Takeda, Koji
    ARTIFICIAL ORGANS, 2024, : 497 - 507
  • [7] Anti-factor Xa activity, prothrombin time, and activated partial thromboplastin time in patients treated with factor Xa inhibitors
    Ryohei Ono
    Kazutaka Nishimura
    Hidehisa Takahashi
    Yasuhiko Hori
    Kenichi Fukushima
    Yoshio Kobayashi
    Naunyn-Schmiedeberg's Archives of Pharmacology, 2023, 396 : 323 - 336
  • [8] Safety of Anticoagulation Reversal in Patients Supported with Continuous-Flow Left Ventricular Assist Devices
    Jennings, Douglas L.
    Jacob, Minu
    Chopra, Anuvrat
    Nemerovski, Carrie W.
    Morgan, Jeffrey A.
    Lanfear, David E.
    ASAIO JOURNAL, 2014, 60 (04) : 381 - 384
  • [9] Activated partial thromboplastin time overestimates anti-coagulation in left ventricular assist device patients
    McIlvennan, Colleen K.
    Page, Robert L., II
    Ambardekar, Amrut V.
    Brieke, Andreas
    Lindenfeld, JoAnn
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (12) : 1312 - 1314
  • [10] Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time
    Cuker, A.
    Ptashkin, B.
    Konkle, B. A.
    Pipe, S. W.
    Whinna, H. C.
    Zheng, X. L.
    Cines, D. B.
    Pollak, E. S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (01) : 80 - 86