Simultaneous determination of amantadine and rimantadine by HPLC in rat plasma with pre-column derivatization and fluorescence detection for pharmacokinetic studies

被引:45
|
作者
Higashi, Y [1 ]
Uemori, I [1 ]
Fujii, Y [1 ]
机构
[1] Hokuriku Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Kanazawa, Ishikawa 9201181, Japan
关键词
amantadine; rimantadine; fluorescent derivatization with o-phthalaldehyde and 2-mercaptoethanol; pharmacokinetic study;
D O I
10.1002/bmc.492
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We investigated simultaneous high-performance liquid chromatographic (HPLC) determination of amantadine hydrochloride (AMA) and rimantadine hydrochloride (RIM) levels in rat plasma after fluorescent derivatization with ophthalalclehyde and 2-mercaptoethanol. Afterwards, the method was applied to determine their pharmacokinetics. The retention times of AMA and RIM derivatives were 12.6 and 22.2 min and the lower limits of detection were 0.025 and 0.016 mu g/mL, respectively. The coefficients of variation for intra- and inter-day assay of AMA and RIM were less than 5.1 and 7.6%, respectively. After i.v. administration of AMA or RIM to rats, the total body clearance and distribution volume at the steady-state of RIM were higher than those of AMA. Bioavailability of AMA and RIM was 34.9 and 37.2%, respectively. When AMA and RIM were p.o. co-administered, the area under the plasma concentration-time curve of RIM was significantly lower than that after RIM alone. On the other hand, pharmacokinetic parameters of AMA did not significantly change. These results indicate that our HPLC assay is simple, rapid, sensitive and reproducible for simultaneously determining AMA and RIM concentrations in rat plasma and is applicable to their pharmacokinetic studies. Also, co-administration of AMA and RIM may result in the lack of pharmacological effects of RIM. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:655 / 662
页数:8
相关论文
共 50 条
  • [1] Determination of fluoxetine and norfluoxetine in rat plasma by HPLC with pre-column derivatization and fluorescence detection
    Guo, XJ
    Fukushima, T
    Li, FM
    Imai, K
    BIOMEDICAL CHROMATOGRAPHY, 2003, 17 (01) : 1 - 5
  • [2] Simple HPLC determination of colistin in medicated feeds by pre-column derivatization and fluorescence detection
    Cancho-Grande, B
    Rodríguez-Comesana, M
    Simal-Gándara, J
    CHROMATOGRAPHIA, 2001, 54 (7-8) : 481 - 484
  • [3] Simple HPLC determination of colistin in medicated feeds by pre-column derivatization and fluorescence detection
    B. Cancho-Grande
    M. Rodríguez-Comesaña
    J. Simal-Gándara
    Chromatographia, 2001, 54 : 481 - 484
  • [4] Determination and Validation of Duloxetine Hydrochloride in Capsules by HPLC with Pre-Column Derivatization and Fluorescence Detection
    Ulu, Sevgi Tatar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (06) : 494 - 498
  • [5] Determination of clarithromycin in rat plasma by HPLC-UV method with pre-column derivatization
    Li, Wei
    Ha, Huijuan
    Zhao, Kang
    TALANTA, 2007, 71 (01) : 385 - 390
  • [6] Optimization of Determination of Reduced and Oxidized Glutathione in Rat Striatum by HPLC Method with Fluorescence Detection and Pre-column Derivatization
    Gawlik, M.
    Krzyzanowska, W.
    Gawlik, M. Bogumila
    Filip, M.
    ACTA CHROMATOGRAPHICA, 2014, 26 (02) : 335 - 345
  • [7] A rapid method for the determination of dopamine in porcine muscle by pre-column derivatization and HPLC with fluorescence detection
    Zhao, Hong-Xia
    Mu, Hui
    Bai, Yan-Hong
    Yu, Hu
    Hu, Ying-Mei
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2011, 1 (03) : 208 - 212
  • [8] DETERMINATION OF MORPHINE IN BIOLOGICAL-FLUIDS BY HPLC WITH PRE-COLUMN DANSYL DERIVATIZATION AND FLUORESCENCE DETECTION
    TAGLIARO, F
    DORIZZI, R
    PLESCIA, M
    PRADELLA, M
    FERRARI, S
    LOCASCIO, V
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (06): : 678 - 679
  • [10] Determination of taurine in cosmetics by HPLC with pre-column derivatization
    Xiao, Gengpeng
    Luo, Chunli
    Huang, Yousheng
    Luo, Xiang
    Chinese Journal of Analysis Laboratory, 2021, 40 (05) : 568 - 572