Development and interinstitutional validation of an automatic vertebral-body misalignment error detector for cone-beam CT-guided radiotherapy

被引:6
|
作者
Luximon, Dishane C. [1 ]
Ritter, Timothy [2 ]
Fields, Emma [2 ]
Neylon, John [1 ]
Petragallo, Rachel [1 ]
Abdulkadir, Yasin [1 ]
Charters, John [1 ]
Low, Daniel A. [1 ]
Lamb, James M. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, 200 UCLA Med Plaza Suite B265,Box 956951, Los Angeles, CA 90095 USA
[2] Virginia Commonwealth Univ, Dept Med Phys, Richmond, VA USA
基金
美国医疗保健研究与质量局;
关键词
deep learning; patient safety; radiation therapy; SURFACE IMAGING-SYSTEM; PATIENT IDENTIFICATION; RADIATION; REGISTRATION; AUDITS;
D O I
10.1002/mp.15927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In cone-beam computed tomography (CBCT)-guided radiotherapy, off-by-one vertebral-body misalignments are rare but serious errors that lead to wrong-site treatments. Purpose An automatic error detection algorithm was developed that uses a three-branch convolutional neural network error detection model (EDM) to detect off-by-one vertebral-body misalignments using planning computed tomography (CT) images and setup CBCT images. Methods Algorithm training and test data consisted of planning CTs and CBCTs from 480 patients undergoing radiotherapy treatment in the thoracic and abdominal regions at two radiotherapy clinics. The clinically applied registration was used to derive true-negative (no error) data. The setup and planning images were then misaligned by one vertebral-body in both the superior and inferior directions, simulating the most likely misalignment scenarios. For each of the aligned and misaligned 3D image pairs, 2D slice pairs were automatically extracted in each anatomical plane about a point within the vertebral column. The three slice pairs obtained were then inputted to the EDM that returned a probability of vertebral misalignment. One model (EDM1) was trained solely on data from institution 1. EDM1 was further trained using a lower learning rate on a dataset from institution 2 to produce a fine-tuned model, EDM2. Another model, EDM3, was trained from scratch using a training dataset composed of data from both institutions. These three models were validated on a randomly selected and unseen dataset composed of images from both institutions, for a total of 303 image pairs. The model performances were quantified using a receiver operating characteristic analysis. Due to the rarity of vertebral-body misalignments in the clinic, a minimum threshold value yielding a specificity of at least 99% was selected. Using this threshold, the sensitivity was calculated for each model, on each institution's test set separately. Results When applied to the combined test set, EDM1, EDM2, and EDM3 resulted in an area under curve of 99.5%, 99.4%, and 99.5%, respectively. EDM1 achieved a sensitivity of 96% and 88% on Institution 1 and Institution 2 test set, respectively. EDM2 obtained a sensitivity of 95% on each institution's test set. EDM3 achieved a sensitivity of 95% and 88% on Institution 1 and Institution 2 test set, respectively. Conclusion The proposed algorithm demonstrated accuracy in identifying off-by-one vertebral-body misalignments in CBCT-guided radiotherapy that was sufficiently high to allow for practical implementation. It was found that fine-tuning the model on a multi-facility dataset can further enhance the generalizability of the algorithm.
引用
收藏
页码:6410 / 6423
页数:14
相关论文
共 33 条
  • [21] UroLift implants as surrogate fiducial markers for cone-beam CT-based prostate image-guided radiotherapy
    Al-Balushi, Ahmed
    Cain, Michelle
    Reynolds, Phil
    Bridge, Pete
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [22] Dosimetric integration of daily mega-voltage cone-beam CT for image-guided intensity-modulated radiotherapy
    Zabel-du Bois, A.
    Nill, S.
    Ulrich, S.
    Oelfke, U.
    Rhein, B.
    Haering, P.
    Milker-Zabel, S.
    Schwahofer, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (02) : 120 - 126
  • [23] Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations
    McMillan, Kyle
    McNitt-Gray, Michael
    Ruan, Dan
    MEDICAL PHYSICS, 2013, 40 (11)
  • [24] Impact of belly board immobilization devices and body mass factor on setup displacement using daily cone-beam CT in rectal cancer radiotherapy
    Ruan, Junjie
    Huang, Xiaotong
    Wang, Tong
    Mai, Xiuying
    Lin, Chuyan
    Li, Fanghua
    Li, Yunfeng
    Chi, Feng
    Li, Bin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):
  • [25] Deep Learning-Based Internal Target Volume (ITV) Prediction Using Cone-Beam CT Images in Lung Stereotactic Body Radiotherapy
    Li, Zhen
    Zhang, Shujun
    Zhang, Libo
    Li, Ya
    Zheng, Xiangpeng
    Fu, Jie
    Qiu, Jianjian
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [26] Automated ultrafast kilovoltage-megavoltage cone-beam CT for image guided radiotherapy of lung cancer: System description and real-time results
    Blessing, Manuel
    Arns, Anna
    Wertz, Hansjoerg
    Stsepankou, Dzmitry
    Boda-Heggemann, Judit
    Hesser, Juergen
    Wenz, Frederik
    Lohr, Frank
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 110 - 120
  • [27] IMPLEMENTATION OF FEEDBACK-GUIDED VOLUNTARY BREATH-HOLD GATING FOR CONE BEAM CT-BASED STEREOTACTIC BODY RADIOTHERAPY
    Peng, Yong
    Vedam, Sastry
    Chang, Joe Y.
    Gao, Song
    Sadagopan, Ramaswamy
    Bues, Martin
    Balter, Peter
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (03): : 909 - 917
  • [28] Virtual clinical trial-based study for clinical evaluation of projection-reduced low-dose cone-beam CT for image guided radiotherapy
    Wang, Meijiao
    Yao, Kaining
    Zhao, Yixin
    Geng, Jianhao
    Zhu, Xianggao
    Liu, Zhiyan
    Li, Yongheng
    Wu, Hao
    Du, Yi
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [29] The clinical feasibility and performance of an orthogonal X-ray imaging system for image-guided radiotherapy in nasopharyngeal cancer patients: Comparison with cone-beam CT
    Zhao, Li-Rong
    Zhou, Yi-Bing
    Li, Guang-Hui
    Li, Qi-Ming
    Yang, Ding-Qiang
    Li, Han-Xu
    Wan, Jiu-Qing
    Sun, Jian-Guo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 266 - 271
  • [30] A Preliminary Simulation Study of Dose-Guided Adaptive Radiotherapy Based on Halcyon MV Cone-Beam CT Images With Retrospective Data From a Phase II Clinical Trial
    Huang, Yuliang
    Wang, Haiyang
    Li, Chenguang
    Hu, Qiaoqiao
    Liu, Hongjia
    Deng, Jun
    Li, Weibo
    Wang, Ruoxi
    Wu, Hao
    Zhang, Yibao
    FRONTIERS IN ONCOLOGY, 2020, 10