Development and interinstitutional validation of an automatic vertebral-body misalignment error detector for cone-beam CT-guided radiotherapy

被引:6
|
作者
Luximon, Dishane C. [1 ]
Ritter, Timothy [2 ]
Fields, Emma [2 ]
Neylon, John [1 ]
Petragallo, Rachel [1 ]
Abdulkadir, Yasin [1 ]
Charters, John [1 ]
Low, Daniel A. [1 ]
Lamb, James M. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, 200 UCLA Med Plaza Suite B265,Box 956951, Los Angeles, CA 90095 USA
[2] Virginia Commonwealth Univ, Dept Med Phys, Richmond, VA USA
基金
美国医疗保健研究与质量局;
关键词
deep learning; patient safety; radiation therapy; SURFACE IMAGING-SYSTEM; PATIENT IDENTIFICATION; RADIATION; REGISTRATION; AUDITS;
D O I
10.1002/mp.15927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In cone-beam computed tomography (CBCT)-guided radiotherapy, off-by-one vertebral-body misalignments are rare but serious errors that lead to wrong-site treatments. Purpose An automatic error detection algorithm was developed that uses a three-branch convolutional neural network error detection model (EDM) to detect off-by-one vertebral-body misalignments using planning computed tomography (CT) images and setup CBCT images. Methods Algorithm training and test data consisted of planning CTs and CBCTs from 480 patients undergoing radiotherapy treatment in the thoracic and abdominal regions at two radiotherapy clinics. The clinically applied registration was used to derive true-negative (no error) data. The setup and planning images were then misaligned by one vertebral-body in both the superior and inferior directions, simulating the most likely misalignment scenarios. For each of the aligned and misaligned 3D image pairs, 2D slice pairs were automatically extracted in each anatomical plane about a point within the vertebral column. The three slice pairs obtained were then inputted to the EDM that returned a probability of vertebral misalignment. One model (EDM1) was trained solely on data from institution 1. EDM1 was further trained using a lower learning rate on a dataset from institution 2 to produce a fine-tuned model, EDM2. Another model, EDM3, was trained from scratch using a training dataset composed of data from both institutions. These three models were validated on a randomly selected and unseen dataset composed of images from both institutions, for a total of 303 image pairs. The model performances were quantified using a receiver operating characteristic analysis. Due to the rarity of vertebral-body misalignments in the clinic, a minimum threshold value yielding a specificity of at least 99% was selected. Using this threshold, the sensitivity was calculated for each model, on each institution's test set separately. Results When applied to the combined test set, EDM1, EDM2, and EDM3 resulted in an area under curve of 99.5%, 99.4%, and 99.5%, respectively. EDM1 achieved a sensitivity of 96% and 88% on Institution 1 and Institution 2 test set, respectively. EDM2 obtained a sensitivity of 95% on each institution's test set. EDM3 achieved a sensitivity of 95% and 88% on Institution 1 and Institution 2 test set, respectively. Conclusion The proposed algorithm demonstrated accuracy in identifying off-by-one vertebral-body misalignments in CBCT-guided radiotherapy that was sufficiently high to allow for practical implementation. It was found that fine-tuning the model on a multi-facility dataset can further enhance the generalizability of the algorithm.
引用
收藏
页码:6410 / 6423
页数:14
相关论文
共 33 条
  • [1] A more effective CT synthesizer using transformers for cone-beam CT-guided adaptive radiotherapy
    Chen, Xinyuan
    Liu, Yuxiang
    Yang, Bining
    Zhu, Ji
    Yuan, Siqi
    Xie, Xuejie
    Liu, Yueping
    Dai, Jianrong
    Men, Kuo
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [2] A deep learning framework for prostate localization in cone beam CT-guided radiotherapy
    Liang, Xiaokun
    Zhao, Wei
    Hristov, Dimitre H.
    Buyyounouski, Mark K.
    Hancock, Steven L.
    Bagshaw, Hilary
    Zhang, Qin
    Xie, Yaoqin
    Xing, Lei
    MEDICAL PHYSICS, 2020, 47 (09) : 4233 - 4240
  • [3] Cone-Beam CT-Guided Lung Biopsies: Results in 94 Patients
    Gulias-Soidan, Daniel
    Crus-Sanchez, Nilfa Milena
    Fraga-Manteiga, Daniel
    Cao-Gonzalez, Juan Ignacio
    Balboa-Barreiro, Vanesa
    Gonzalez-Martin, Cristina
    DIAGNOSTICS, 2020, 10 (12)
  • [4] Evaluation of a workflow for cone-beam CT-guided online adaptive palliative radiotherapy planned using diagnostic CT scans
    Nelissen, Koen J.
    Versteijne, Eva
    Senan, Suresh
    Hoffmans, Daan
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (03):
  • [5] TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery
    Uneri, A.
    Schafer, S.
    Mirota, D. J.
    Nithiananthan, S.
    Otake, Y.
    Taylor, R. H.
    Siewerdsen, J. H.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 159 - 173
  • [6] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [7] Dosimetric Study of Deep Learning-Guided ITV Prediction in Cone-beam CT for Lung Stereotactic Body Radiotherapy
    Zhang, Shujun
    Lv, Bo
    Zheng, Xiangpeng
    Li, Ya
    Ge, Weiqiang
    Zhang, Libo
    Mo, Fan
    Qiu, Jianjian
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [8] A dual cone-beam CT system for image guided radiotherapy: Initial performance characterization
    Li, Hao
    Giles, William
    Bowsher, James
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2013, 40 (02)
  • [9] Planning CT-guided robust and fast cone-beam CT scatter correction using a local filtration technique
    Cui, Hehe
    Jiang, Xiao
    Fang, Chengyijue
    Zhu, Lei
    Yang, Yidong
    MEDICAL PHYSICS, 2021, 48 (11) : 6832 - 6843
  • [10] Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images
    Marchant, T. E.
    Joshi, K. D.
    Moore, C. J.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132