Accurate estimation of pharmacokinetic contrast-enhanced dynamic MRI parameters of the prostate

被引:87
作者
Huisman, HJ [1 ]
Engelbrecht, MR [1 ]
Barentsz, JO [1 ]
机构
[1] Univ Nijmegen, Med Ctr St Radboud, Dept Radiol, Nijmegen, Netherlands
关键词
MRI; contrast-enhanced; curve fitting methods; accuracy; prostate;
D O I
10.1002/jmri.1085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative analysis of contrast-enhanced dynamic MR images has potential for diagnosing prostate cancer. Contemporary fast acquisition techniques can give sufficiently high temporal resolution to sample the fast dynamics observed In the prostate. Data reduction for parametric visualization requires automatic curve fitting to a pharmacokinetic model, which to date has been performed using least-squares error minimization methods. We observed that these methods often produce unexpectedly noisy estimates, especially for the typically fast, intermediate parameters time-to-peak and start-of-enhancement, resulting in inaccurate pharmacokinetic parameter estimates. We developed a new curve fit method that focuses on the most probable slope. A set of 10 patients annotated using histopathology was used to compare the conventional and new methods. The results show that our new method Is significantly more accurate, especially in the relatively less-enhancing periferal zone. We conclude that estimation accuracy depends on the curve fit method, which is especially important when evaluating the periferal zone of the prostate. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 35 条
[11]   Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging [J].
FritzHansen, T ;
Rostrup, E ;
Larsson, HBW ;
Sondergaard, L ;
Ring, P ;
Henriksen, O .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :225-231
[12]  
Gevenois P A, 1992, J Belge Radiol, V75, P5
[13]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914
[14]   METHOD FELL THE QUANTITATIVE ASSESSMENT OF CONTRAST AGENT UPTAKE IN DYNAMIC CONTRAST-ENHANCED MRT [J].
HITTMAIR, K ;
GOMISCEK, G ;
LANGENBERGER, K ;
RECHT, M ;
IMHOF, H ;
KRAMER, J .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :567-571
[15]   CARCINOMA OF THE PROSTATE-GLAND - MR-IMAGING WITH PELVIC PHASED-ARRAY COILS VERSUS INTEGRATED ENDORECTAL PELVIC PHASED-ARRAY COILS [J].
HRICAK, H ;
WHITE, S ;
VIGNERON, D ;
KURHANEWICZ, J ;
KOSCO, A ;
LEVIN, D ;
WEISS, J ;
NARAYAN, P ;
CARROLL, PR .
RADIOLOGY, 1994, 193 (03) :703-709
[16]   Precision and accuracy of acoustospectrographic parameters [J].
Huisman, HJ ;
Thijssen, JM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :855-871
[17]   Accurate estimation of contrast agent dynamics in fast contrast enhanced MRI [J].
Huisman, HJ ;
Barentsz, JO .
MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 :338-346
[18]  
Ihaka R., 1996, J COMPUTATIONAL GRAP, V5, P299, DOI [DOI 10.1080/10618600.1996.10474713, 10.1080/10618600.1996.10474713, 10.2307/1390807]
[19]   Dynamic TurboFLASH subtraction technique for contrast-enhanced MR imaging of the prostate: Correlation with histopathologic results [J].
Jager, GJ ;
Ruijter, ETG ;
vanderKaa, CA ;
delaRosette, JJMCH ;
Oosterhof, GON ;
Thornbury, JR ;
Ruijs, SHJ ;
Barentsz, JO .
RADIOLOGY, 1997, 203 (03) :645-652
[20]   A new method for imaging perfusion and contrast extraction fraction: Input functions derived from reference tissues [J].
Kovar, DA ;
Lewis, M ;
Karczmar, GS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1126-1134