Accurate estimation of pharmacokinetic contrast-enhanced dynamic MRI parameters of the prostate

被引:87
作者
Huisman, HJ [1 ]
Engelbrecht, MR [1 ]
Barentsz, JO [1 ]
机构
[1] Univ Nijmegen, Med Ctr St Radboud, Dept Radiol, Nijmegen, Netherlands
关键词
MRI; contrast-enhanced; curve fitting methods; accuracy; prostate;
D O I
10.1002/jmri.1085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative analysis of contrast-enhanced dynamic MR images has potential for diagnosing prostate cancer. Contemporary fast acquisition techniques can give sufficiently high temporal resolution to sample the fast dynamics observed In the prostate. Data reduction for parametric visualization requires automatic curve fitting to a pharmacokinetic model, which to date has been performed using least-squares error minimization methods. We observed that these methods often produce unexpectedly noisy estimates, especially for the typically fast, intermediate parameters time-to-peak and start-of-enhancement, resulting in inaccurate pharmacokinetic parameter estimates. We developed a new curve fit method that focuses on the most probable slope. A set of 10 patients annotated using histopathology was used to compare the conventional and new methods. The results show that our new method Is significantly more accurate, especially in the relatively less-enhancing periferal zone. We conclude that estimation accuracy depends on the curve fit method, which is especially important when evaluating the periferal zone of the prostate. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 35 条
[1]  
Barentsz JO, 1999, J MAGN RESON IMAGING, V10, P295, DOI 10.1002/(SICI)1522-2586(199909)10:3<295::AID-JMRI10>3.0.CO
[2]  
2-Z
[3]   MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE [J].
BOETES, C ;
BARENTSZ, JO ;
MUS, RD ;
VANDERSLUIS, RF ;
VANERNING, LJTO ;
HENDRIKS, JHCL ;
HOLLAND, R ;
RUYS, SHJ .
RADIOLOGY, 1994, 193 (03) :777-781
[4]   PHARMACOKINETIC PARAMETERS IN CNS GD-DTPA ENHANCED MR IMAGING [J].
BRIX, G ;
SEMMLER, W ;
PORT, R ;
SCHAD, LR ;
LAYER, G ;
LORENZ, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :621-628
[5]   THE ROLE OF INTRAVENOUS CONTRAST ENHANCEMENT IN MAGNETIC-RESONANCE-IMAGING OF PROSTATIC-CARCINOMA [J].
BROWN, G ;
MACVICAR, DA ;
AYTON, V ;
HUSBAND, JE .
CLINICAL RADIOLOGY, 1995, 50 (09) :601-606
[6]   QUANTITATIVE-ANALYSIS OF MULTISLICE GD-DTPA ENHANCED DYNAMIC MR-IMAGES USING AN AUTOMATED SIMPLEX MINIMIZATION PROCEDURE [J].
BUCKLEY, DL ;
KERSLAKE, RW ;
BLACKBAND, SJ ;
HORSMAN, A .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :646-651
[7]   Microvessel density as a predictor of PSA recurrence after radical prostatectomy - A comparison of CD34 and CD31 [J].
de la Taille, A ;
Katz, AE ;
Bagiella, E ;
Buttyan, R ;
Sharir, S ;
Olsson, CA ;
Burchardt, T ;
Ennis, RD ;
Rubin, MA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2000, 113 (04) :555-562
[8]  
ENGELBRECHT M, 2000, P 8 ANN M ISMRM DENV
[9]  
Evelhoch JL, 1999, JMRI-J MAGN RESON IM, V10, P254, DOI 10.1002/(SICI)1522-2586(199909)10:3<254::AID-JMRI5>3.0.CO
[10]  
2-9