Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams

被引:1
作者
Ogata, Toshiyuki [1 ]
Nishimura, Hideki [2 ]
Mayahara, Hiroshi [2 ]
Uehara, Kazuyuki [1 ]
Okayama, Takanobu [1 ]
机构
[1] Kobe Minimally Invas Canc Ctr, Div Med Technol Support, Chuo Ku, 8-5-1 Minatojima Nakamachi, Kobe, Hyogo, Japan
[2] Kobe Minimally Invas Canc Ctr, Dept Radiat Oncol, Kobe, Hyogo, Japan
基金
日本学术振兴会;
关键词
FFF beams; SBRT; Leaf margin; CONFORMITY INDEX; THERAPY; VOLUME;
D O I
10.1016/j.meddos.2017.06.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study is to identify the suitable leaf margin for liver stereotactic body radiotherapy (SBRT) with flattening filter-free (FFF) beams, as compared with that with flattening filter (FF) beams. SBRT treatment planning for 10 patients with liver cancer was performed using 10-MV FFF and FF beams obtained from a Varian TrueBeam (Varian Medical Systems, Palo Alto, CA) linear accelerator. Each plan was generated with the leaf margin to the planning target volume (PTV) ranging from -3 to 5 mm. The prescription dose at D95 (dose covering 95% of the volume) was 48 Gy in 4 fractions to the PTV. The following dosimetric parameters were evaluated quantitatively: homogeneity index (HI), conformity index (CI), gradient index (GI), the normal liver receiving a dose greater than or equal to 20 Gy (V20), and the mean normal liver dose. The HI for FFF and FF beams increased as the leaf margin decreased. The leaf margins that achieved the best CI and GI were 0.1 and -0.3 mm for FFF beams, and 0.1 and -0.9 mm for FF beams. The liver V20 and the mean liver dose reached their minimum values at leaf margins of -0.8 and 0.0 mm for FFF beams, and -0.8 and 0.0 mm for FF beams. The suitable leaf margin for SBRT planning did not differ significantly for FFF and FF beams. Our data showed that, for both FFF and FF beams, a leaf margin of 0 or -1 mm was optimal for liver SBRT planning in terms of both target coverage and normal tissue sparing. (C) 2017 American Association of Medical Dosimetrists.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 13 条
  • [1] STEREOTACTIC BODY RADIOTHERAPY FOR PRIMARY HEPATOCELLULAR CARCINOMA
    Andolino, David L.
    Johnson, Cynthia S.
    Maluccio, Mary
    Kwo, Paul
    Tector, A. Joseph
    Zook, Jennifer
    Johnstone, Peter A. S.
    Cardenes, Higinia R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04): : E447 - E453
  • [2] Determining the optimal block margin on the planning target volume for extracranial stereotactic radiotherapy
    Cardinale, RM
    Wu, QW
    Benedict, SH
    Kavanagh, BD
    Bunp, E
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 515 - 520
  • [3] Conformity index:: A review
    Feuvret, L
    Noël, G
    Mazeron, JJ
    Bey, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02): : 333 - 342
  • [4] Current status and future perspective of flattening filter free photon beams
    Georg, Dietmar
    Knoos, Tommy
    McClean, Brendan
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1280 - 1293
  • [5] COMMISSIONING OF PHOTON BEAMS OF A FLATTENING FILTER-FREE LINEAR ACCELERATOR AND THE ACCURACY OF BEAM MODELING USING AN ANISOTROPIC ANALYTICAL ALGORITHM
    Hrbacek, Jan
    Lang, Stephanie
    Kloeck, Stephan
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1228 - 1237
  • [6] International Commission on Radiation Units and Measurements, 2010, J ICRU, V10
  • [7] Clinical application of flattening filter free beams for extracranial stereotactic radiotherapy
    Lang, Stephanie
    Shrestha, Binaya
    Graydon, Shaun
    Cavelaars, Frederique
    Linsenmeier, Claudia
    Hrbacek, Jan
    Kloeck, Stephan
    Studer, Gabriela
    Riesterer, Oliver
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 106 (02) : 255 - 259
  • [8] Dosimetric Impact of Intrafraction Motion During RapidArc Stereotactic Vertebral Radiation Therapy Using Flattened and Flattening Filter-Free Beams
    Ong, Chin Loon
    Dahele, Max
    Cuijpers, Johan P.
    Senan, Suresh
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 420 - 425
  • [9] A simple dose gradient measurement tool to complement the conformity index
    Paddick, Ian
    Lippitz, Bodo
    [J]. JOURNAL OF NEUROSURGERY, 2006, 105 : 194 - 201
  • [10] Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis
    Reggiori, Giacomo
    Mancosu, Pietro
    Castiglioni, Simona
    Alongi, Filippo
    Pellegrini, Chiara
    Lobefalo, Francesca
    Catalano, Maddalena
    Fogliata, Antonella
    Arcangeli, Stefano
    Navarria, Piera
    Cozzi, Luca
    Scorsetti, Marta
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1112 - 1118