Internal electrical fault detection techniques in DFIG-based wind turbines: a review

被引:36
作者
Bebars, Abdelwahab D. [1 ]
Eladl, Abdelfattah A. [1 ]
Abdulsalam, Gabr M. [1 ]
Badran, Ebrahim A. [1 ]
机构
[1] Mansoura Univ, Fac Engn, Elect Engn Dept, Mansoura, Egypt
关键词
DFIG; Wind turbines; Internal fault detection; Reliability improvement; FED INDUCTION GENERATORS; TURN SHORT-CIRCUIT; SIGNATURE ANALYSIS; STATOR WINDINGS; ROTOR; DIAGNOSIS; MACHINES; MOTORS; MODEL; POWER;
D O I
10.1186/s41601-022-00236-z
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The keys factor in making wind power one of the main power sources to meet the world's growing energy demands is the reliability improvement of wind turbines (WTs). However, the eventuality of fault occurrence on WT components cannot be avoided, especially for doubly-fed induction generator (DFIG) based WTs, which are operating in severe environments. The maintenance need increases due to unexpected faults, which in turn leads to higher operating cost and poor reliability. Extensive investigation into DFIG internal fault detection techniques has been carried out in the last decade. This paper presents a detailed review of these techniques. It discusses the methods that can be used to detect internal electrical faults in a DFIG stator, rotor, or both. A novel sorting technique is presented which takes into consideration different parameters such as fault location, detection technique, and DFIG modelling. The main mathematical representation used to detect these faults is presented to allow an easier and faster understanding of each method. In addition, a comparison is carried out in every section to illustrate the main differences, advantages, and disadvantages of every method and/or model. Some real monitoring systems available in the market are presented. Finally, recommendations for the challenges, future work, and main gaps in the field of internal faults in a DFIG are presented. This review is organized in a tutorial manner, to be an effective guide for future research for enhancing the reliability of DFIG-based WTs.
引用
收藏
页数:22
相关论文
共 122 条
[1]  
Abad G., 2011, DOUBLY FED INDUCTION, DOI [10.1002/9781118104965, DOI 10.1002/9781118104965]
[2]  
Abad Miguel Angel, 2014, 2014 17th International Conference on Information Fusion (FUSION 2014)
[3]  
Abadi MB, 2014, IEEE IND ELEC, P2037, DOI 10.1109/IECON.2014.7048782
[4]   On-line stator winding fault diagnosis in induction generators for renewable generation [J].
Albizu, I ;
Tapia, A ;
Saenz, JR ;
Mazón, AJ ;
Zamora, I .
MELECON 2004: PROCEEDINGS OF THE 12TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1-3, 2004, :1017-1020
[5]   A brief status on condition monitoring and fault diagnosis in wind energy conversion systems [J].
Amirat, Y. ;
Benbouzid, M. E. H. ;
Al-Ahmar, E. ;
Bensaker, B. ;
Turri, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (09) :2629-2636
[6]  
[Anonymous], 2009, 13 EUR C POW EL APPL
[7]  
Antonino-Daviu J, 2013, IEEE IND ELEC, P5555, DOI 10.1109/IECON.2013.6700043
[8]   Reliable Detection of Rotor Winding Asymmetries in Wound Rotor Induction Motors via Integral Current Analysis [J].
Antonino-Daviu, Jose ;
Quijano-Lopez, Alfredo ;
Climente-Alarcon, Vicente ;
Garin-Abellan, Carlos .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :2040-2048
[9]   Model Based Fault Detection and Diagnosis of Doubly Fed Induction Generators - A Review [J].
Balasubramanian, A. ;
Muthu, Ranganath .
FIRST INTERNATIONAL CONFERENCE ON POWER ENGINEERING COMPUTING AND CONTROL (PECCON-2017 ), 2017, 117 :935-942
[10]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993