DEVELOPMENT AND VALIDATION OF A QUANTITATIVE HS-GC/FID METHOD FOR ALCOHOL ANALYSIS IN BIOLOGICAL SAMPLES: STABILITY ASSESMENT

被引:0
|
作者
Bujaroska, Marija [1 ,5 ]
Bozhinoska, Zorica [1 ]
Vujovic, Maja [3 ,4 ]
Milosavljevic, Biljana [4 ]
Stankov, Aleksandar [1 ]
Ivanovska, Tanja Petreska [2 ]
Poposka, Verica [1 ]
Tozi, Lidija Petrushevska [2 ]
机构
[1] Ss Cyril & Methodius Univ, Inst Forens Med Criminol & Med Deontol, Med Fac, Skopje, North Macedonia
[2] Ss Cyril & Methodius Univ, Fac Pharm, Inst Appl Biochem, Dept Toxicol, Skopje, North Macedonia
[3] Univ Nis, Med Fac, Dept Pharm, Nish, Serbia
[4] Inst Forens Med, Nish, Serbia
[5] Ss Cyril & Methodius Univ, Med Fac, Inst Forens Med Criminol & Med Deontol, 19 Vodnjanska Majka Tereza, Skopje 1000, North Macedonia
来源
ROMANIAN JOURNAL OF LEGAL MEDICINE | 2022年 / 30卷 / 01期
关键词
ethyl alcohol; blood; validation; stability; HEADSPACE GAS-CHROMATOGRAPHY; POSTMORTEM BLOOD; FLAME-IONIZATION; VITREOUS-HUMOR; ETHANOL; ACETALDEHYDE; ANTEMORTEM; METHANOL; ACETONE;
D O I
10.4323/rjlm.2022.53
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Determination of blood alcohol concentration is one of the most common analyses in forensic toxicology laboratory practice. With reference to this, the aim of the present work was to develop a method for quantitative analysis of ethyl alcohol in blood by head space gas chromatography, with n-propanol as an internal standard and at the same time ensuring good resolution of ethyl alcohol and acetone using one capillary column. Validation parameters comprising selectivity, specificity, linearity, accuracy and precision have indicated that the method could be applied in routine analysis of ethyl alcohol in post-mortem and ante-mortem blood samples as well as in other biological fluids, in line with the set criteria based on the revised international guidelines. In post-mortem samples there are many interfering substances due to various reasons (as a result of acidosis, produced in vitro on account of an improper storage of the samples or during the autolysis / putrefaction phase of the body). Because of this occurrence, within the validation procedure, more attention was imparted to the stability of the samples, including processed sample, freeze-thaw and long-term stability estimation. The results of the additional stability tests have shown that applying of preservative significantly improved the stability of the samples by inhibiting the in vitro ethyl alcohol production.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [21] Method development and validation for the GC-FID assay of tributyl phosphate in a phospholipid emulsion
    Kesslen, E
    Thomas, B
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (01) : 155 - 160
  • [22] Development and validation of a GC-FID method for quantitation of impurities in kemantane drug substance
    A. V. Tolkacheva
    L. N. Grushevskaya
    N. I. Avdyunina
    B. M. Pyatin
    V. I. Prokofeva
    L. M. Gaevaya
    Pharmaceutical Chemistry Journal, 2013, 47 : 330 - 336
  • [23] Monitoring of the Wines' Quality by Gas Chromatography: HSS-GC/FID Method Development, Validation, Verification, for Analysis of Volatile Compounds
    Sorgic, Sasa
    Sredovic Ignjatovic, Ivana
    Antic, Malisa
    Sacirovic, Sabina
    Pezo, Lato
    Cejic, Vladimir
    Durovic, Sasa
    FERMENTATION-BASEL, 2022, 8 (02):
  • [24] Method development and validation of arene substituted regioisomers in a pharmaceutical candidate by high temperature GC-FID
    Salisbury, John J.
    Do, Nga M.
    Ragan, John A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 109 : 74 - 78
  • [25] Validation of a method for ethanol analysis in biological and non-biological samples and its toxicological application
    Kostic, Emilija
    Vujovic, Maja
    Milosavljevic, Biljana
    HEMIJSKA INDUSTRIJA, 2021, 75 (03) : 175 - 183
  • [26] ANALYTICAL PERFORMANCE AND VALIDATION OF HEAD SPACE-GAS CHROMATOGRAPHY-FLAME IONIZATION DETECTOR (HS-GC-FID) METHOD FOR ALCOHOL CONTENT AND EVALUATION OF EFFICIENCY AND POSSIBLE TOXICITY OF HAND SANITIZERS AT THE TIME OF PANDEMIC
    Berkkan, Aysel
    Ulutas, Onur Kenan
    REVUE ROUMAINE DE CHIMIE, 2021, 66 (06) : 547 - 556
  • [27] Method development and validation for the GC-FID assay of p-cymene in tea tree oil formulation
    Shabir, GA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 681 - 684
  • [28] Development and validation of a chiral UHPLC-MS method for the analysis of cysteine enantiomers in biological samples
    Pucciarini, Lucia
    Gonzalez-Ruiz, Victor
    Zangari, Josephine
    Martinou, Jean-Claude
    Natalini, Benedetto
    Sardella, Roccaldo
    Rudaz, Serge
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 177
  • [29] Quantitative chromatographic method development for residual lidocaine in topical systems and biological samples
    Bhatt, Jayshil A.
    Wei, Hui
    Azarpanah, Armita
    Morris, Kenneth R.
    Cai, Qing
    BIOANALYSIS, 2023, 15 (10) : 553 - 566
  • [30] Development and Validation of a Method for the Detection and Quantification of Antidepressants and Antipsychotics in Bone Samples by GC-MS
    Laudani, Antonino
    Sangregorio, Deborah
    Zuccarello, Pietro
    Licciardello, Teresa
    Grasso, Stephanie
    Romano, Guido
    Barbera, Nunziata
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (09) : 957 - 960