Point-of-Care Echocardiography by Pediatric Emergency Physicians

被引:82
作者
Longjohn, Mindy [1 ]
Wan, Jim [3 ]
Joshi, Vijay [2 ]
Pershad, Jay [1 ]
机构
[1] Univ Tennessee, Ctr Hlth Sci, Dept Pediat, Div Emergency Serv, Memphis, TN 38163 USA
[2] Univ Tennessee, Ctr Hlth Sci, Dept Pediat, Div Pediat Cardiol, Memphis, TN 38163 USA
[3] Univ Tennessee, Ctr Hlth Sci, Dept Prevent Med, Memphis, TN 38163 USA
关键词
point-of-care; echocardiography; cardiac; BEDSIDE ULTRASOUND INBU; TRANSTHORACIC ECHOCARDIOGRAPHY; VOLUME ASSESSMENT; CARDIAC-FUNCTION; EARLY-DIAGNOSIS; SHOCK; UNIT; RESUSCITATION; ACCURACY; PRESSURE;
D O I
10.1097/PEC.0b013e318226c7c7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Currently, pediatric emergency medicine (PEM) physicians have limited data on point-of-care echocardiography (POCE). Our goals were to (1) determine the overall accuracy of POCE by PEMs in assessing left ventricular (LV) systolic function visually, presence or absence of pericardial effusion, and cardiac preload by estimating inferior vena cava (IVC) collapsibility, in acutely ill children in the pediatric emergency department; and (2) assess interobserver agreement between the PEM physician and pediatric cardiologist. Methods: This is a prospective, observational study conducted in an urban, tertiary pediatric facility with an annual census of 67,000 emergency department visits. Patients between the ages of 0 and 18 years meeting 1 or more of the following inclusion criteria were recruited: (1) cardiopulmonary arrest, (2) fluid refractory shock requiring vasoactive infusions, (3) undifferentiated cardiomegaly on chest radiography, and (4) receiving emergent formal echocardiography. All eligible patients underwent POCE by 1 of 2 trained PEM physicians. Dynamic video clips were recorded and reviewed by a pediatric cardiologist who was unaware of the clinical condition of the study patients. Results: For a period of 18 months, we recruited 70 patients. Diminished LV function was noted in 17, pericardial effusion in 16, and abnormal IVC collapsibility in 35 patients. The kappa statistics of agreement between the PEM and the cardiologist for detection of LV function, IVC collapsibility, and effusion were 0.87 (95% confidence interval [CI], 0.73-1.00), 0.73 (95% CI, 0.59-0.88), and 0.77 (95% CI, 0.58-0.95), respectively. The overall sensitivity and specificity of POCE compared with a formal echocardiogram was 95% (95% CI, 82%-99%) and 83% (95% CI, 64%-93%), respectively. Conclusions: With goal-directed training, PEM physicians may be able to perform POCE and accurately assess for significant LV systolic dysfunction, vascular filling, and the presence of pericardial effusion. The model may be expanded to train physicians to use POCE.
引用
收藏
页码:693 / 696
页数:4
相关论文
共 27 条
[1]   Focused echocardiographic evaluation in resuscitation management: Concept of an advanced life support-conformed algorithm [J].
Breitkreutz, Raoul ;
Walcher, Felix ;
Seeger, Florian H. .
CRITICAL CARE MEDICINE, 2007, 35 (05) :S150-S161
[2]   Use of echocardiography for hemodynamic monitoring [J].
Brown, JM .
CRITICAL CARE MEDICINE, 2002, 30 (06) :1361-1364
[3]   Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: A pilot study [J].
Carr, Brendan G. ;
Dean, Anthony J. ;
Everett, Worth W. ;
Ku, Bon S. ;
Mark, Dustin G. ;
Okusanya, Olugbenga ;
Horan, Annamarie D. ;
Gracias, Vicente H. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (03) :495-500
[4]   Posterior urethral valves presenting as abdominal distension and undifferentiated shock in a neonate: The role of screening emergency physician-directed bedside ultrasound [J].
Gilmore, B ;
Noe, HN ;
Chin, T ;
Pershad, J .
JOURNAL OF EMERGENCY MEDICINE, 2004, 27 (03) :265-269
[5]   Accuracy of cardiac function and volume status estimates using the Bedside Echocardiographic Assessment in Trauma/Critical Care [J].
Gunst, Mark ;
Ghaemmaghami, Vafa ;
Sperry, Jason ;
Robinson, Melissa ;
O'Keeffe, Terence ;
Friese, Randall ;
Frankel, Heidi .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 65 (03) :509-515
[6]   Transthoracic echocardiography to identify or exclude cardiac cause of shock [J].
Joseph, MX ;
Disney, PJS ;
Da Costa, R ;
Hutchison, SJ .
CHEST, 2004, 126 (05) :1592-1597
[7]   Sonographic inferior vena cava/aorta diameter index, a new approach to the body fluid status assessment in children and young adults in emergency ultrasound - preliminary study [J].
Kosiak, Wojciech ;
Swieton, Dominik ;
Piskunowicz, Maciej .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (03) :320-325
[8]   Bedside ultrasound in pediatric emergency medicine [J].
Levy, Jason A. ;
Noble, Vicki E. .
PEDIATRICS, 2008, 121 (05) :E1404-E1412
[9]   Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients [J].
Manasia, AR ;
Nagaraj, HM ;
Kodali, RB ;
Croft, LB ;
Oropello, JM ;
Kohli-Seth, R ;
Leibowitz, AB ;
DelGiudice, R ;
Oropello, JM ;
Kohli-Seth, R ;
Leibowitz, AB ;
DelGiudice, R ;
Hufanda, JF ;
Benjamin, E ;
Goldman, ME .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (02) :155-159
[10]   Bedside echocardiography in chest trauma [J].
Mandavia, DP ;
Joseph, A .
EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2004, 22 (03) :601-+