Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources

被引:20
作者
Granero, D. [3 ]
Perez-Calatayud, J. [3 ]
Ballester, F. [1 ,2 ]
机构
[1] Univ Valencia, Dept Atom Mol & Nucl Phys, CSIC, E-46100 Burjassot, Spain
[2] Univ Valencia, IFIC, E-46100 Burjassot, Spain
[3] La Fe Univ Hosp, Dept Radiat Oncol, Phys Sect, E-46009 Valencia, Spain
关键词
HDR; PDR; Ir-192; dosimetry; brachytherapy; Monte Carlo;
D O I
10.1118/1.2868766
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The two most commonly used modalities of cancer treatment in clinical brachytherapy practice today are high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy. In a clinical treatment, quality dose rate distribution data sets of the brachytherapy sources are required for each source model. The purpose of this study is to obtain detailed dose rate distributions around the new BEBIG HDR and PDR Ir-192 brachytherapy sources. These distributions will then be used as input data in the treatment planning systems dedicated to brachytherapy and its calculations can be verified. The Monte Carlo method was used to obtain the dose rate distributions around the sources studied, taking into account the AAPM-ESTRO recent recommendations. A complete dosimetric data set for the BEBIG Ir-192 HDR and PDR sources, types Ir2.A85-2 and Ir2.A85-1, were obtained. This dosimetric data set is composed of the TG-43 dosimetric functions and parameters and along-away dose rate table to facilitate quality control of treatment planning systems. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1280 / 1287
页数:8
相关论文
共 26 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], 1997, UCRL 50400
[3]   Monte Carlo dosimetric study of best industries and alpha omega Ir-192 brachytherapy seeds [J].
Ballester, F ;
Granero, D ;
Pérez-Calatayud, J ;
Casal, E ;
Puchades, V .
MEDICAL PHYSICS, 2004, 31 (12) :3298-3305
[4]   Monte Carlo calculation of dose rate distributions around Ir-192 wires [J].
Ballester, F ;
Hernandez, C ;
PerezCalatayud, J ;
Lliso, F .
MEDICAL PHYSICS, 1997, 24 (08) :1221-1228
[5]   Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources [J].
Ballester, F ;
Puchades, V ;
Lluch, JL ;
Serrano-Andrés, MA ;
Limami, Y ;
Pérez-Calatayud, J ;
Casal, E .
MEDICAL PHYSICS, 2001, 28 (12) :2586-2591
[6]   Beta versus gamma dosimetry close to Ir-192 brachytherapy sources [J].
Baltas, D ;
Karaiskos, P ;
Papagiannis, P ;
Sakelliou, L ;
Loeffler, E ;
Zamboglou, N .
MEDICAL PHYSICS, 2001, 28 (09) :1875-1882
[7]   ROOT - An object oriented data analysis framework [J].
Brun, R ;
Rademakers, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (1-2) :81-86
[8]   Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source [J].
Daskalov, GM ;
Loffler, E ;
Williamson, JF .
MEDICAL PHYSICS, 1998, 25 (11) :2200-2208
[9]  
Gerbaulet A, 2002, The GEC ESTRO Handbook of Brachytherapy: Part II-Ch 14: Cervix Carcinoma
[10]   A dosimetric study on the Ir-192 high dose rate Flexisource [J].
Granero, D. ;
Perez-Calatayud, J. ;
Casal, E. ;
Ballester, F. ;
Venselaar, J. .
MEDICAL PHYSICS, 2006, 33 (12) :4578-4582