TREATMENT AND DOSIMETRIC ADVANTAGES BETWEEN VMAT, IMRT, AND HELICAL TOMOTHERAPY IN PROSTATE CANCER

被引:77
|
作者
Tsai, Chiao-Ling
Wu, Jian-Kuen
Chao, Hsiao-Ling
Tsai, Yi-Chun
Cheng, Jason Chia-Hsien [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Oncol, Div Radiat Oncol, Taipei 100, Taiwan
关键词
Volumetric modulated arc therapy; Intensity-modulated radiation therapy; Helical tomotherapy; Prostate cancer; MODULATED RADIATION-THERAPY; RANDOMIZED CONTROLLED-TRIAL; CONFORMAL RADIOTHERAPY; DOSE-RESPONSE; ARC; OPTIMIZATION; DELIVERY; PLANS;
D O I
10.1016/j.meddos.2010.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We investigated the possible treatment and dosimetric advantage of volumetric modulated arc therapy (VMAT) over step-and-shoot intensity-modulated radiation therapy (step-and-hhoot IMRT) and helical tomotherapy (HT). Twelve prostate cancer patients undergoing VMAT to the prostate were included. Three treatment plans (VMAT, step-and-shoot IMRT, HT) were generated for each patient. The doses to clinical target volume and 95% of planning target volume were both >= 78 Gy. Target coverage, conformity index, dose to rectum/bladder, monitor units (MU), treatment time, equivalent uniform dose (EUD), normal tissue complication probability (NTCP) of targets, and rectum/bladder were compared between techniques. HT provided superior conformity and significantly less rectal volume exposed to 65 Gy and 40 Gy, as well as EUD/NTCP of rectum than step-and-shoot IMRT, whereas VMAT had a slight dosimetric advantage over step-and-shoot IMRT. Notably, significantly lower MUs were needed for VMAT (309.7 +/- 35.4) and step-and-shoot IMRT (336.1 +/- 16.8) than for HT (3368 +/- 638.7) (p < 0.001). The treatment time (minutes) was significantly shorter for VMAT (2.6 +/- 0.5) than step-and-shoot IMRT (3.8 +/- 0.3) and HT (3.8 +/- 0.6) (p < 0.001). Dose verification of VMAT using point dose and film dosimetry met the accepted criteria. VMAT and step-and-shoot IMRT have comparable dosimetry, but treatment efficiency is significantly higher for VMAT than for step-and-shoot IMRT and HT. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 50 条
  • [31] Dosimetric Comparison of Helical Tomotherapy and HyperArc Treatment Plans for Angiosarcoma of the Scalp
    Inui, Shoki
    Takahashi, Yutaka
    Ueda, Yoshihiro
    Ohira, Shingo
    Washio, Hayate
    Ono, Shunsuke
    Miyazaki, Masayoshi
    Nishio, Teiji
    Koizumi, Masahiko
    Konishi, Koji
    ANTICANCER RESEARCH, 2023, 43 (07) : 3079 - 3087
  • [32] Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment
    Jonathan Khalifa
    Laure Vieillevigne
    Sabrina Boyrie
    Monia Ouali
    Thomas Filleron
    Michel Rives
    Anne Laprie
    Radiation Oncology, 9
  • [33] Dosimetric Comparison of IMRT and VMAT for Retinoblastoma Treatment: A treatment Planning Study
    Patil, Deepali
    Madhawi, Richa
    Zope, Mukesh K. U. M. A. R.
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2025, 40 (01): : 51 - 59
  • [34] Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment
    Khalifa, Jonathan
    Vieillevigne, Laure
    Boyrie, Sabrina
    Ouali, Monia
    Filleron, Thomas
    Rives, Michel
    Laprie, Anne
    RADIATION ONCOLOGY, 2014, 9 : 247
  • [35] Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma
    Martin, Spencer
    Chen, Jeff Z.
    Dar, A. Rashid
    Yartsev, Slav
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 431 - 437
  • [36] COMPARISON OF PROSTATE IMRT AND VMAT BIOLOGICALLY OPTIMISED TREATMENT PLANS
    Hardcastle, Nicholas
    Tome, Wolfgang A.
    Foo, Kerwyn
    Miller, Andrew
    Carolan, Martin
    Metcalfe, Peter
    MEDICAL DOSIMETRY, 2011, 36 (03) : 292 - 298
  • [37] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Yang, Ruijie
    Wang, Junjie
    Xu, Shouping
    Li, Hua
    BMC CANCER, 2013, 13
  • [38] Dosimetric comparison of helical tomotherapy, VMAT, fixed-field IMRT and 3D-conformal radiotherapy for stage I-II nasal natural killer T-cell lymphoma
    Liu, Xianfeng
    Huang, Erliang
    Wang, Ying
    He, Yanan
    Luo, Huanli
    Zhong, Mingsong
    Qiu, Da
    Li, Chao
    Yang, Han
    He, Guanglei
    Zhou, Juan
    Jin, Fu
    RADIATION ONCOLOGY, 2017, 12
  • [39] Reduction of dosimetric impact of intrafractional prostate motion during helical tomotherapy
    Prokic, V.
    Geinitz, H.
    Kneschaurek, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (05) : 404 - 409
  • [40] Helical tomotherapy for the treatment of anal canal cancer: a dosimetric comparison with 3D conformal radiotherapy
    Ugurluer, Gamze
    Ballerini, Giorgio
    Moeckli, Raphael
    Matzinger, Oscar
    Bourhis, Jean
    Ozsahin, Mahmut
    TUMORI, 2015, 101 (03) : 268 - 272