TREATMENT AND DOSIMETRIC ADVANTAGES BETWEEN VMAT, IMRT, AND HELICAL TOMOTHERAPY IN PROSTATE CANCER

被引:77
|
作者
Tsai, Chiao-Ling
Wu, Jian-Kuen
Chao, Hsiao-Ling
Tsai, Yi-Chun
Cheng, Jason Chia-Hsien [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Oncol, Div Radiat Oncol, Taipei 100, Taiwan
关键词
Volumetric modulated arc therapy; Intensity-modulated radiation therapy; Helical tomotherapy; Prostate cancer; MODULATED RADIATION-THERAPY; RANDOMIZED CONTROLLED-TRIAL; CONFORMAL RADIOTHERAPY; DOSE-RESPONSE; ARC; OPTIMIZATION; DELIVERY; PLANS;
D O I
10.1016/j.meddos.2010.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We investigated the possible treatment and dosimetric advantage of volumetric modulated arc therapy (VMAT) over step-and-shoot intensity-modulated radiation therapy (step-and-hhoot IMRT) and helical tomotherapy (HT). Twelve prostate cancer patients undergoing VMAT to the prostate were included. Three treatment plans (VMAT, step-and-shoot IMRT, HT) were generated for each patient. The doses to clinical target volume and 95% of planning target volume were both >= 78 Gy. Target coverage, conformity index, dose to rectum/bladder, monitor units (MU), treatment time, equivalent uniform dose (EUD), normal tissue complication probability (NTCP) of targets, and rectum/bladder were compared between techniques. HT provided superior conformity and significantly less rectal volume exposed to 65 Gy and 40 Gy, as well as EUD/NTCP of rectum than step-and-shoot IMRT, whereas VMAT had a slight dosimetric advantage over step-and-shoot IMRT. Notably, significantly lower MUs were needed for VMAT (309.7 +/- 35.4) and step-and-shoot IMRT (336.1 +/- 16.8) than for HT (3368 +/- 638.7) (p < 0.001). The treatment time (minutes) was significantly shorter for VMAT (2.6 +/- 0.5) than step-and-shoot IMRT (3.8 +/- 0.3) and HT (3.8 +/- 0.6) (p < 0.001). Dose verification of VMAT using point dose and film dosimetry met the accepted criteria. VMAT and step-and-shoot IMRT have comparable dosimetry, but treatment efficiency is significantly higher for VMAT than for step-and-shoot IMRT and HT. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:264 / 271
页数:8
相关论文
共 50 条
  • [21] A Dosimetric Comparison of 7 Field IMRT, 9 Field IMRT, VMAT and 3-D Conformal Radiotherapy for the Treatment of Localized Intermediate Risk Prostate Cancer
    Ekici, Kemal
    Kuloglu, Mehmet
    Ata, Aysun Ozsoy
    Atahan, Ozcan
    Tiryakioglu, Osman
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2022, 32 (03): : 133 - 140
  • [22] Evaluation of image-guidance strategies with helical tomotherapy for localised prostate cancer
    Yeung, Timothy P. C.
    Yartsev, Slav
    Rodrigues, George
    Bauman, Glenn
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (02) : 220 - 228
  • [23] Helical Tomotherapy in Elderly Prostate Cancer Patients
    Ki, Yong Kan
    Nam, Ji Ho
    Kim, Won Taek
    Park, Dahl
    Kim, Dong Hyun
    Lee, Ju Hye
    Jeon, Ho Sang
    Kim, Dong Won
    ANNALS OF GERIATRIC MEDICINE AND RESEARCH, 2013, 17 (02): : 79 - 85
  • [24] Dosimetric comparison of volumetric-modulated arc therapy and helical tomotherapy for adjuvant treatment of bilateral breast cancer
    Phurailatpam, Reena
    Wadasadawala, Tabassum
    Chauhan, Kamalnayan
    Panda, Subhajit
    Sarin, Rajiv
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 36 - 44
  • [25] Report on planning comparison of VMAT, IMRT and helical tomotherapy for the ESCALOX-trial pre-study
    Pigorsch, Steffi U.
    Kampfer, Severin
    Oechsner, Markus
    Mayinger, Michael C.
    Mozes, Petra
    Devecka, Michal
    Kessel, Kerstin K.
    Combs, Stephanie E.
    Wilkens, Jan J.
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [26] A Planning Comparison of Dynamic IMRT for Different Collimator Leaf Thicknesses with Helical Tomotherapy and RapidArc for Prostate and Head and Neck Tumors
    Jacob, Vesna
    Bayer, Wolfgang
    Astner, Sabrina T.
    Busch, R.
    Kneschaurek, Peter
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 (09) : 502 - 510
  • [27] Effect of Photon-Beam Energy on VMAT and IMRT Treatment Plan Quality and Dosimetric Accuracy for Advanced Prostate Cancer
    Pasler, Marlies
    Georg, Dietmar
    Wirtz, Holger
    Lutterbach, Johannes
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (12) : 792 - 798
  • [28] Helical tomotherapy-based hypofractionated radiotherapy for prostate cancer: A report on the procedure, dosimetry and preliminary clinical outcome
    Murthy, Vedang
    Krishnatry, Rahul
    Mallik, Suman
    Master, Zubin
    Mahantshetty, Umesh
    Shrivastava, Shyamkishore
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (02) : 253 - 260
  • [29] Dosimetric comparison of fixed field dynamic IMRT and VMAT techniques in simultaneous integrated boost radiotherapy of prostate cancer
    Sun, Haitao
    Wang, Ning
    Huang, Guosen
    Liu, Xiangping
    MEDICINE, 2022, 101 (50) : E32063
  • [30] Dosimetric Investigation of FIF, VMAT, IMRT, H-VMAT, and H-IMRT Planning Techniques in Breast Cancer Radiotherapy
    Canbolat, Hilal Sarac
    Demircan, Niyazi Volkan
    Dinc, Serap Catli
    Senturk, Ertugrul
    Bora, Huseyin
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2023, 38 (01): : 45 - 51