Real-time Lissajous imaging with a low-voltage 2-axis MEMS scanner based on electrothermal actuation

被引:50
作者
Tanguy, Quentin A. A. [1 ,2 ]
Gaiffe, Olivier [1 ,3 ]
Passilly, Nicolas [1 ]
Cote, Jean-Marc [1 ]
Cabodevila, Gonzalo [1 ]
Bargiel, Sylwester [1 ]
Lutz, Philippe [1 ]
Xie, Huikai [2 ]
Gorecki, Christophe [1 ]
机构
[1] Univ Bourgogne Franche Comte, KNSMM, CNRS, Inst FEMTO ST UMR6174, F-25000 Besancon, France
[2] Univ Florida, Gainesville, FL 32611 USA
[3] CHU Besancon, Serv ORL, F-25000 Besancon, France
基金
美国国家科学基金会;
关键词
IN-VIVO; RESOLUTION; ENDOSCOPE; DIAMETER; CATHETER; RANGE; SPEED; 2D;
D O I
10.1364/OE.380690
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser scanning based on Micro-Electro-Mechanical Systems (MEMS) scanners has become very attractive for biomedical endoscopic imaging, such as confocal microscopy or Optical Coherence Tomography (OCT). These scanners are required to be fast to achieve real-time image reconstruction while working at low actuation voltage to comply with medical standards. In this context, we report a 2-axis Micro-Electro-Mechanical Systems (MEMS) electrothermal micro-scannercapable of imaging large fields of view at high frame rates, e.g. from 10 to 80 frames per second. For this purpose, Lissajous scan parameters are chosen to provide the optimal image quality within the scanner capabilities and the sampling rate limit, resulting from the limited A-scan rate of typical swept-sources used for OCT. Images of 233 px x 203 px and 53 px x 53 px at 10 fps and 61 fps, respectively, are experimentally obtained and demonstrate the potential of this micro-scannerfor high definition and high frame rate endoscopic Lissajous imaging. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:8512 / 8527
页数:16
相关论文
共 44 条
[1]   Two-axis MEMS scanning catheter for ultrahigh resolution three-dimensional and en face imaging [J].
Aguirre, Aaron D. ;
Herz, Paul R. ;
Chen, Yu ;
Fujimoto, James G. ;
Piyawattanametha, Wibool ;
Fan, Li ;
Wu, Ming C. .
OPTICS EXPRESS, 2007, 15 (05) :2445-2453
[2]   Scanning and Tunable Micro-Optics for Endoscopic Optical Coherence Tomography [J].
Aljasem, Khaled ;
Froehly, Luc ;
Seifert, Andreas ;
Zappe, Hans .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2011, 20 (06) :1462-1472
[3]   High-speed Lissajous-scan atomic force microscopy: Scan pattern planning and control design issues [J].
Bazaei, A. ;
Yong, Yuen K. ;
Moheimani, S. O. Reza .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (06)
[4]   Angiography of the retina and the choroid with phase-resolved OCT using interval-optimized backstitched B-scans [J].
Braaf, Boy ;
Vermeer, Koenraad A. ;
Vienola, Kari V. ;
de Boer, Johannes F. .
OPTICS EXPRESS, 2012, 20 (18) :20516-20534
[5]   Constant linear velocity spiral scanning for near video rate 4D OCT ophthalmic and surgical imaging with isotropic transverse sampling [J].
Carrasco-Zevallos, Oscar M. ;
Viehland, Christian ;
Keller, Brenton ;
McNabb, Ryan P. ;
Kuo, Anthony N. ;
Izatt, Joseph A. .
BIOMEDICAL OPTICS EXPRESS, 2018, 9 (10) :5052-5070
[6]  
Dougherty G., 2009, DIGITAL IMAGE PROCES, DOI DOI 10.1017/CBO9780511609657
[7]   Optical coherence tomography endoscopic probe based on a tilted MEMS mirror [J].
Duan, Can ;
Tanguy, Quentin ;
Pozzi, Antonio ;
Xie, Huikai .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (09) :3344-3353
[8]   A Self-Aligned 45°-Tilted Two-Axis Scanning Micromirror for Side-View Imaging [J].
Duan, Can ;
Wang, Wei ;
Zhang, Xiaoyang ;
Zhou, Liang ;
Pozzi, Antonio ;
Xie, Huikai .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2016, 25 (04) :799-811
[9]   Swept-source common-path optical coherence tomography with a MEMS endoscopic imaging probe [J].
Duan, Can ;
Wang, Donglin ;
Zhou, Zhengwei ;
Liang, Peng ;
Samuelson, Sean R. ;
Pozzi, Antonio ;
Xie, Huikai .
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
[10]   Visualizing epithelial expression of EGFR in vivo with distal scanning side-viewing confocal endomicroscope [J].
Duan, Xiyu ;
Li, Haijun ;
Zhou, Juan ;
Zhou, Quan ;
Oldham, Kenn R. ;
Wang, Thomas D. .
SCIENTIFIC REPORTS, 2016, 6