Renal Normothermic Machine Perfusion: The Road Toward Clinical Implementation of a Promising Pretransplant Organ Assessment Tool

被引:34
作者
Hamelink, Tim L. [1 ]
Ogurlu, Baran [1 ]
De Beule, Julie [2 ]
Lantinga, Veerle A. [1 ]
Pool, Merel B. F. [1 ]
Venema, Leonie H. [1 ]
Leuvenink, Henri G. D. [1 ]
Jochmans, Ina [2 ,3 ]
Moers, Cyril [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg Organ Donat & Transplantat, CMC V Y2144,BA44,Hanzepl 1, NL-9713 GZ Groningen, Netherlands
[2] Katholieke Univ Leuven, Lab Abdominal Transplantat, Dept Microbiol Immunol & Transplantat, Transplantat Res Grp, Leuven, Belgium
[3] Univ Hosp Leuven, Dept Abdominal Transplant Surg, Leuven, Belgium
关键词
VIVO KIDNEY PERFUSION; DECLINED HUMAN KIDNEYS; DECEASED-DONOR KIDNEY; COLD ISCHEMIC-INJURY; LUNG PERFUSION; GRAFT FUNCTION; URINARY BIOMARKERS; QUALITY ASSESSMENT; ENDOTHELIAL-CELLS; ARTERIAL-PRESSURE;
D O I
10.1097/TP.0000000000003817
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The increased utilization of high-risk renal grafts for transplantation requires optimization of pretransplant organ assessment strategies. Current decision-making methods to accept an organ for transplantation lack overall predictive power and always contain an element of subjectivity. Normothermic machine perfusion (NMP) creates near-physiological conditions, which might facilitate a more objective assessment of organ quality before transplantation. NMP is rapidly gaining popularity, with various transplant centers developing their own NMP protocols and renal viability criteria. However, to date, no validated sets of on-pump viability markers exist nor are there unified NMP protocols. This review provides a critical overview of the fundamentals of current renal NMP protocols and proposes a framework to approach further development of ex vivo organ evaluation. We also comment on the potential logistical implications of routine clinical use of NMP, which is a more complex procedure compared with static cold storage or even hypothermic machine perfusion.
引用
收藏
页码:268 / 279
页数:12
相关论文
共 146 条
[31]   Ischemia and reperfusion-from mechanism to translation [J].
Eltzschig, Holger K. ;
Eckle, Tobias .
NATURE MEDICINE, 2011, 17 (11) :1391-1401
[32]   Principles, techniques, and limitations of near infrared spectroscopy [J].
Ferrari, M ;
Mottola, L ;
Quaresima, V .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2004, 29 (04) :463-487
[33]   Oxidative Stress in Kidney Transplantation: Malondialdehyde Is an Early Predictive Marker of Graft Dysfunction [J].
Fonseca, Isabel ;
Reguengo, Henrique ;
Almeida, Manuela ;
Dias, Leonidio ;
Martins, La Salete ;
Pedroso, Sofia ;
Santos, Josefina ;
Lobato, Luisa ;
Henriques, Antonio Castro ;
Mendonca, Denisa .
TRANSPLANTATION, 2014, 97 (10) :1058-1065
[34]   Transplantation of Cold Stored Porcine Kidneys After Controlled Oxygenated Rewarming [J].
Gallinat, Anja ;
Lu, Jing ;
von Horn, Charlotte ;
Kaths, Moritz ;
Ingenwerth, Marc ;
Paul, Andreas ;
Minor, Thomas .
ARTIFICIAL ORGANS, 2018, 42 (06) :647-654
[35]   Glutathione S-Transferase Iso-Enzymes in Perfusate From Pumped Kidneys Are Associated With Delayed Graft Function [J].
Hall, I. E. ;
Bhangoo, R. S. ;
Reese, P. P. ;
Doshi, M. D. ;
Weng, F. L. ;
Hong, K. ;
Lin, H. ;
Han, G. ;
Hasz, R. D. ;
Goldstein, M. J. ;
Schroeppel, B. ;
Parikh, C. R. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (04) :886-896
[36]   Normothermic Ex Vivo Kidney Perfusion Reduces Warm Ischemic Injury of Porcine Kidney Grafts Retrieved After Circulatory Death [J].
Hamar, Matyas ;
Urbanellis, Peter ;
Kaths, Moritz Johann ;
Kollmann, Dagmar ;
Linares, Ivan ;
Ganesh, Sujani ;
Wiebe, Aryn ;
Cen, Jun Yu ;
Yip, Paul ;
John, Rohan ;
Konvalinka, Ana ;
Mucsi, Istvan ;
Ghanekar, Anand ;
Bagli, Darius ;
Grant, David ;
Robinson, Lisa A. ;
Selzner, Markus .
TRANSPLANTATION, 2018, 102 (08) :1262-1270
[37]   Early Graft Loss After Kidney Transplantation: Risk Factors and Consequences [J].
Hamed, M. O. ;
Chen, Y. ;
Pasea, L. ;
Watson, C. J. ;
Torpey, N. ;
Bradley, J. A. ;
Pettigrew, G. ;
Saeb-Parsy, K. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15 (06) :1632-1643
[38]   Brief Normothermic Machine Perfusion Rejuvenates Discarded Human Kidneys [J].
Hameed, Ahmer M. ;
Lu, David B. ;
Patrick, Ellis ;
Xu, Bo ;
Hu, Min ;
Chew, Yi Vee ;
Keung, Karen ;
P'ng, Chow H. ;
Gaspi, Renan ;
Zhang, Chris ;
Robertson, Paul ;
Alexander, Stephen ;
Thomas, Gordon ;
Laurence, Jerome ;
De Roo, Ronald ;
Wong, Germaine ;
Miraziz, Ray ;
O'Grady, Greg ;
Yuen, Lawrence ;
Hawthorne, Wayne J. ;
Rogers, Natasha M. ;
Pleass, Henry C. .
TRANSPLANTATION DIRECT, 2019, 5 (11) :E502
[39]   Leucocyte depletion improves renal function during reperfusion using an experimental isolated haemoperfused organ preservation system [J].
Harper, S. ;
Hosgood, S. ;
Kay, M. ;
Nicholson, M. .
BRITISH JOURNAL OF SURGERY, 2006, 93 (05) :623-629
[40]   The effect of warm ischemic time on renal function and injury in the isolated hemoperfused kidney [J].
Harper, Simon J. F. ;
Hosgood, Sarah A. ;
Waller, Helen L. ;
Yang, Bin ;
Kay, Mark D. ;
Goncalves, Ines ;
Nicholson, Michael L. .
TRANSPLANTATION, 2008, 86 (03) :445-451