共 50 条
Outcome After Partial Medial Meniscus Substitution With the Collagen Meniscal Implant at a Minimum of 10 Years' Follow-up
被引:90
|作者:
Carlos Monllau, Juan
[1
,2
]
Eduardo Gelber, Pablo
[1
,2
]
Abat, Ferran
[1
]
Pelfort, Xavier
[2
]
Abad, Rosa
[3
]
Hinarejos, Pedro
Tey, Marc
[2
]
机构:
[1] Univ Autonoma Barcelona, Hosp St Pau, Dept Orthopaed Surg, Barcelona 08025, Spain
[2] Univ Autonoma Barcelona, Inst Univ Dexeus ICATME, Barcelona 08025, Spain
[3] Hosp Gen Granollers, Barcelona, Spain
关键词:
KNEE;
REGENERATION;
CARTILAGE;
SCORE;
D O I:
10.1016/j.arthro.2011.02.018
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Purpose: The aim of the study was to evaluate the clinical outcome of a collagen meniscus graft implanted in an injured medial meniscus after a minimum of 10 years' follow-up. Methods: Twenty-five patients underwent arthroscopic implantation of the collagen meniscus device. They had either persistent compartmental joint line pain due to a previous medial meniscus resection (5 cases) or a large irreparable meniscus tear at arthroscopy (20 cases). Implant failure was defined as infection due to the implant or mechanical failure of the device. Twenty-two patients returned for clinical, functional, and radiographic evaluation. Magnetic resonance imaging was also performed and was analyzed with the criteria of Genovese et al. (where type 3 indicates normal and type 1 indicates completely abnormal). All the aforementioned evaluations were carried out at a minimum of 10 years (range, 10.1 to 12.5 years) after the procedure. Results: The mean Lysholm score improved from 59.9 preoperatively to 89.6 at 1 year (P < .001), and it was 87.5 at final follow-up (P < .001). The results were good or excellent in 83% of the population. No differences were observed when we compared the Lysholm score at 1 year of follow-up with the score at final follow-up (P > .05). The mean pain score on a visual analog scale improved by 3.5 points at final follow-up. Patient satisfaction with the procedure was 3.4 of 4 points. Radiographic evaluation showed either minimal or no narrowing of the joint line. Magnetic resonance imaging showed type 2 in 64% of cases and type 3 in 21%. All cases showed less volume than expected (size type 2 in 89%). The failure rate in the patient population was 8% (2 of 25). There were no complications related to the device. Conclusions: Although there were several different types of patients and acute and chronic tears were treated in a limited number of patients, meniscal substitution with the collagen meniscal implant provides significant pain relief and functional improvement after a minimum of 10 years' follow-up. The implant generally diminished in size, but the procedure proved to be safe and had a low rate of implant failure on a long-term basis. No development or progression of degenerative knee joint disease was observed in most cases. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:933 / 943
页数:11
相关论文