Outcome After Partial Medial Meniscus Substitution With the Collagen Meniscal Implant at a Minimum of 10 Years' Follow-up

被引:90
|
作者
Carlos Monllau, Juan [1 ,2 ]
Eduardo Gelber, Pablo [1 ,2 ]
Abat, Ferran [1 ]
Pelfort, Xavier [2 ]
Abad, Rosa [3 ]
Hinarejos, Pedro
Tey, Marc [2 ]
机构
[1] Univ Autonoma Barcelona, Hosp St Pau, Dept Orthopaed Surg, Barcelona 08025, Spain
[2] Univ Autonoma Barcelona, Inst Univ Dexeus ICATME, Barcelona 08025, Spain
[3] Hosp Gen Granollers, Barcelona, Spain
关键词
KNEE; REGENERATION; CARTILAGE; SCORE;
D O I
10.1016/j.arthro.2011.02.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The aim of the study was to evaluate the clinical outcome of a collagen meniscus graft implanted in an injured medial meniscus after a minimum of 10 years' follow-up. Methods: Twenty-five patients underwent arthroscopic implantation of the collagen meniscus device. They had either persistent compartmental joint line pain due to a previous medial meniscus resection (5 cases) or a large irreparable meniscus tear at arthroscopy (20 cases). Implant failure was defined as infection due to the implant or mechanical failure of the device. Twenty-two patients returned for clinical, functional, and radiographic evaluation. Magnetic resonance imaging was also performed and was analyzed with the criteria of Genovese et al. (where type 3 indicates normal and type 1 indicates completely abnormal). All the aforementioned evaluations were carried out at a minimum of 10 years (range, 10.1 to 12.5 years) after the procedure. Results: The mean Lysholm score improved from 59.9 preoperatively to 89.6 at 1 year (P < .001), and it was 87.5 at final follow-up (P < .001). The results were good or excellent in 83% of the population. No differences were observed when we compared the Lysholm score at 1 year of follow-up with the score at final follow-up (P > .05). The mean pain score on a visual analog scale improved by 3.5 points at final follow-up. Patient satisfaction with the procedure was 3.4 of 4 points. Radiographic evaluation showed either minimal or no narrowing of the joint line. Magnetic resonance imaging showed type 2 in 64% of cases and type 3 in 21%. All cases showed less volume than expected (size type 2 in 89%). The failure rate in the patient population was 8% (2 of 25). There were no complications related to the device. Conclusions: Although there were several different types of patients and acute and chronic tears were treated in a limited number of patients, meniscal substitution with the collagen meniscal implant provides significant pain relief and functional improvement after a minimum of 10 years' follow-up. The implant generally diminished in size, but the procedure proved to be safe and had a low rate of implant failure on a long-term basis. No development or progression of degenerative knee joint disease was observed in most cases. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:933 / 943
页数:11
相关论文
共 50 条
  • [21] Clinical outcome and failure analysis of medial meniscus bucket-handle tear repair: a series of 96 patients with a minimum 2 year follow-up
    Mathieu Thaunat
    Gaspard Fournier
    Padhraig O’Loughlin
    Biova Teko Kouevidjin
    Gilles Clowez
    Matteo Borella
    Jean-Marie Fayard
    Bertrand Sonnery-Cottet
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1649 - 1654
  • [22] Medial Unicompartmental Knee Arthroplasty in Patients Less Than 55 Years Old: Minimum of Two Years of Follow-Up
    Biswas, Debdut
    Van Thiel, Geoffrey S.
    Wetters, Nathan G.
    Pack, Bryan J.
    Berger, Richard A.
    Della Valle, Craig J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01) : 101 - 105
  • [23] Medial Meniscus Scaffold Implantation in Combination with Concentrated Bone Marrow Aspirate Injection: Minimum 3-Year Follow-up
    Akkaya, Mustafa
    Simsek, Mehmet Emin
    Gursoy, Safa
    Cay, Nurdan
    Bozkurt, Murat
    JOURNAL OF KNEE SURGERY, 2020, 33 (08) : 838 - 846
  • [24] Good subjective outcome and low risk of revision surgery with a novel customized metal implant for focal femoral chondral lesions at a follow-up after a minimum of 5 years
    Mohanad Al-Bayati
    Nicolas Martinez-Carranza
    David Roberts
    Magnus Högström
    Anders Stålman
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2887 - 2892
  • [25] Favourable long-term functional and radiographical outcome after osteoautograft transplantation surgery of the knee: a minimum 10-year follow-up
    Ekman, Elina
    Makela, Keijo
    Kohonen, Ia
    Hiltunen, Ari
    Itala, Ari
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (12) : 3560 - 3565
  • [26] Favourable long-term functional and radiographical outcome after osteoautograft transplantation surgery of the knee: a minimum 10-year follow-up
    Elina Ekman
    Keijo Mäkelä
    Ia Kohonen
    Ari Hiltunen
    Ari Itälä
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3560 - 3565
  • [27] Good subjective outcome and low risk of revision surgery with a novel customized metal implant for focal femoral chondral lesions at a follow-up after a minimum of 5 years
    Al-Bayati, Mohanad
    Martinez-Carranza, Nicolas
    Roberts, David
    Hogstrom, Magnus
    Stalman, Anders
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2887 - 2892
  • [28] Implant design influences the joint-specific outcome after total knee arthroplasty data from a randomized controlled trial at a minimum 12 years' follow-up
    Clement, N.
    MacDonald, D. J.
    Hamilton, D. F.
    Gaston, P.
    BONE & JOINT OPEN, 2024, 5 (10): : 911 - 919
  • [29] Long-term results of arthroscopic Bankart repair: Minimum 10 years of follow-up
    Flinkkila, Tapio
    Knape, Rony
    Sirnio, Kai
    Ohtonen, Pasi
    Leppilahti, Juhana
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (01) : 94 - 99
  • [30] Clinical and Radiological Long-term Outcomes After Matrix-Induced Autologous Chondrocyte Transplantation A Prospective Follow-up at a Minimum of 10 Years
    Aldrian, Silke
    Zak, Lukas
    Wondrasch, Barbara
    Albrecht, Christian
    Stelzeneder, Beate
    Binder, Harald
    Kovar, Florian
    Trattnig, Siegfried
    Marlovits, Stefan
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (11) : 2680 - 2688