Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study

被引:35
作者
Garpebring, Anders [1 ]
Wirestam, Ronnie [2 ]
Ostlund, Nils [3 ]
Karlsson, Mikael [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, Div Radiat Phys, SE-90187 Umea, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Umea Univ Hosp, Dept Radiat Sci, Div Biomed Engn & Informat, S-90185 Umea, Sweden
基金
瑞典研究理事会;
关键词
dynamic contrast-enhanced MRI; arterial input function; blood flow effects; RF spoiling; HIGH-TEMPORAL-RESOLUTION; FAST GRADIENT-ECHO; BLOOD-VOLUME; IMPROVED ACCURACY; T-1; MEASUREMENT; FLOWING BLOOD; PERMEABILITY; PERFUSION; T1; QUANTIFICATION;
D O I
10.1002/mrm.22760
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of accuracy in the pharmacokinetic parameters. These errors were investigated for a 3D spoiled gradient-echo sequence using a pulsatile flow phantom and a total of 144 typical imaging settings. In the presence of large inflow effects, results showed poor average accuracy and large spread between imaging settings, when the standard spoiled gradient-echo signal equation was used in the analysis. For example, one of the investigated inflow conditions resulted in a mean error of about 40% and a spread, given by the coefficient of variation, of 20% for K-trans. Minimizing inflow effects by appropriate slice placement, combined with compensation for nonideal radiofrequency spoiling, significantly improved the results, but they remained poorer than without flow (e. g., 3-4 times larger coefficient of variation for K-trans). It was concluded that the 3D spoiled gradient-echo sequence is not optimal for accurate arterial input function quantification and that correction for nonideal radiofrequency spoiling in combination with inflow minimizing slice placement should be used to reduce the errors. Magn Reson Med 65:1670-1679, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1670 / 1679
页数:10
相关论文
共 46 条
[31]   Comparative study iinto the robustness of compartmental modeling and model-free analysis in DCE-MRI studies [J].
Roberts, C ;
Issa, B ;
Stone, A ;
Jackson, A ;
Waterton, JC ;
Parker, GJM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (04) :554-563
[32]   Quantifying Spatial Heterogeneity in Dynamic Contrast-Enhanced MRI Parameter Maps [J].
Rose, Chris J. ;
Mills, Samantha J. ;
O'Connor, James P. B. ;
Buonaccorsi, Giovanni A. ;
Roberts, Caleb ;
Watson, Yvonne ;
Cheung, Susan ;
Zhao, Sha ;
Whitcher, Brandon ;
Jackson, Alan ;
Parker, Geoffrey J. M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) :488-499
[33]   Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences [J].
Schabel, Matthias C. ;
Parker, Dennis L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :2345-2373
[34]  
Stanisz GJ, 2000, MAGNET RESON MED, V44, P665, DOI 10.1002/1522-2594(200011)44:5<665::AID-MRM1>3.0.CO
[35]  
2-M
[36]   Influence of the Compliance of the Neck Arteries and Veins on the Measurement of Intracranial Volume Change by Phase-Contrast MRI [J].
Tain, Rong-Wen ;
Ertl-Wagner, Birgit ;
Alperin, Noam .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) :878-883
[37]   Modeling tracer kinetics in dynamic Gd-DTPA MR imaging [J].
Tofts, PS .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :91-101
[38]   Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI [J].
Treier, Reto ;
Steingoetter, Andreas ;
Fried, Michael ;
Schwizer, Werner ;
Boesiger, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) :568-576
[39]   Factors influencing flip angle mapping in MRI:: RF pulse shape, slice-select gradients, off-resonance excitation, and Bo inhomogeneities [J].
Wang, Jinghua ;
Mao, Weihua ;
Qiu, Maolin ;
Smith, Michael B. ;
Constable, R. Todd .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :463-468
[40]   Dynamic contrast enhanced magnetic resonance imaging in oncology: Theory, data acquisition, analysis, and examples [J].
Yankeelov, Thomas E. ;
Gore, John C. .
CURRENT MEDICAL IMAGING REVIEWS, 2007, 3 (02) :91-107