Stem subsidence after total hip revision: 183 cases at 5.9 years follow-up

被引:29
|
作者
Girard, J. [1 ]
Roche, O. [2 ]
Wavreille, G. [3 ]
Canovas, F. [4 ]
Le Beguec, P. [5 ]
机构
[1] N Lille Univ, Sports & Med Unit, F-59000 Lille, France
[2] Nancy Teaching Hosp Ctr, Orthopaed & Traumatol Surg Ctr, F-54000 Nancy, France
[3] Roger Salengro Hosp, Lille Reg Acad Hosp Ctr, Dept Orthopaed, F-59037 Lille, France
[4] Lapeyronie Hosp, Montpellier Teaching Hosp Ctr, Orthopaed & Traumatol Dept, F-34295 Montpellier, France
[5] Galeries Theatre 11, F-35000 Rennes, France
关键词
Revision total hip arthroplasty; Stress shielding; Femorotomy; Press-fit; Stem subsidence; POROUS-COATED STEMS; FEMORAL REVISION; DISTAL FIXATION; ARTHROPLASTY; REPLACEMENT; DISLOCATION; COMPONENTS; FRACTURES; FAILURE; FEMUR;
D O I
10.1016/j.otsr.2010.10.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Secondary subsidence of a revision femoral stem is often a negative predictive sign for successful osseointegration and perfect long-term stability. Materials and methods: We performed a retrospective study in a series of 183 revision total hip replacements between 1996 and 2000 to evaluate the importance and risk factors of secondary subsidence with a cementless press-fit design femoral stem as well as this subsidence's consequences to osseointegration. Results: Secondary subsidence did not occur in 80 cases (53%), was between 0 and 4mm in 41 cases (27%); between 5 and 10mm in 17 cases (12%) and was greater than 10mm in 12 cases (8%). Mean subsidence of all patients was 3mm (0-30). There was a statistically significant negative correlation between subsidence and the quality of osseointegration (P = 0.03). There was no significant relationship between component diameter and stem subsidence (P = 0.9). The presence of preoperative bone deficiencies did not increase the risk of secondary subsidence (P = 0.2). Conclusion: In the case of revision with press-fit stems, the importance of secondary subsidence should not be overestimated, because it usually does not negatively affect satisfactory osseointegration.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [1] Reproducible fixation with a tapered, fluted, modular, titanium stem in revision hip arthroplasty at 8-15 years follow-up
    Rodriguez, Jose A.
    Deshmukh, Ajit J.
    Robinson, Jonathan
    Cornell, Charles N.
    Rasquinha, Vijay J.
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 214 - 218
  • [2] Revision total hip arthroplasty in patients with femoral bone loss using tapered rectangular femoral stem: a minimum 10 years' follow-up
    Wang, Jian
    Dai, Wen-Li
    Lin, Ze-Ming
    Shi, Zhan-Jun
    HIP INTERNATIONAL, 2020, 30 (05) : 622 - 628
  • [3] Long-Term Outcomes of Revision Total Hip Arthroplasty Using a Tapered and Fluted Modular Stem: A Mean Follow-Up of 16 Years
    Park, Chan -Woo
    Lee, Jong-Hyun
    Shin, Sang Soo
    Moon, Young-Wan
    Lim, Seung-Jae
    Park, Youn-Soo
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12) : 2420 - 2426
  • [4] Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
    Lakemeier, Stefan
    Aurand, Guenter
    Timmesfeld, Nina
    Heyse, Thomas J.
    Fuchs-Winkelmann, Susanne
    Schofer, Markus D.
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [5] 6 years follow-up of hip revision surgery
    Orban, H.
    Stan, G.
    Gheorghiu, N.
    Dragusanu, M.
    Mares, E.
    Orban, C.
    CHIRURGIA, 2012, 107 (02) : 226 - 230
  • [6] Long Term Results With the Interlocking Uncemented Long Stem in Revision Hip Arthroplasty: A Mean 15-Year Follow-Up
    Kamada, Tomomi
    Imai, Hiroshi
    Mashima, Naohiko
    Takeba, Jun
    Okumura, Hideo
    Miura, Hiromasa
    JOURNAL OF ARTHROPLASTY, 2015, 30 (05) : 835 - 839
  • [7] Revision hip arthroplasty with a rectangular tapered cementless stem: a retrospective study of the SLR-Plus stem at a mean follow-up of 4.1 years
    Uriarte, Iker
    Moreta, Jesus
    Cortes, Laura
    Bernuy, Lucia
    Aguirre, Urko
    Martinez de los Mozos, Jose Luis
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (02) : 281 - 289
  • [8] Circumferential proximal femoral allografts in revision hip arthroplasty: four to 20 years follow-up
    Roos, Bruno Dutra
    Roos, Milton Valdomiro
    Camisa, Antero, Jr.
    HIP INTERNATIONAL, 2013, 23 (01) : 66 - 71
  • [9] Results of revision total hip arthroplasty with Anatomic BR stem: 10-year minimum follow-up
    Tsukeoka, Tadashi
    Lee, Tae Hyun
    Tsuruoka, Hiroaki
    Murata, Tadao
    Suzuki, Masahiko
    MODERN RHEUMATOLOGY, 2011, 21 (05) : 482 - 487
  • [10] The use of a long stem cemented femoral component in revision total hip replacement A FOLLOW-UP STUDY OF FIVE TO 16 YEARS
    te Stroet, M. A. J.
    Bronsema, E.
    Rijnen, W. H. C.
    Gardeniers, J. W. M.
    Schreurs, B. W.
    BONE & JOINT JOURNAL, 2014, 96B (09) : 1207 - 1213