Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length

被引:126
作者
Lim, Seon-A [2 ]
Cha, Jung-Yul [1 ]
Hwang, Chung-Ju [1 ]
机构
[1] Yonsei Univ, Coll Dent, Dept Orthodont, Seoul 120752, South Korea
[2] Private Clin, Seoul 120752, South Korea
关键词
miniscrew; insertion torque; diameter; length;
D O I
10.2319/121206-507.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape. Materials and Methods: The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, and pitches were tested. Results: The results showed that the insertion torque significantly increased with increasing screw length (P <.01). In particular, there was a significant increase in torque with increasing screw length and diameter (P <.01). An analysis of the serial insertion torque of miniscrews revealed the cylindrical type screw to have much higher insertion torque at the incomplete screw thread, while the taper type screw showed a much higher insertion torque at the final inclination part of the screw thread. The insertion torque was affected by the outer diameter, length, and shape in that order. Conclusions: An increase in screw diameter can efficiently reinforce the initial stability of the miniscrew, but the proximity of the root at the implanted site should be considered.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 32 条
[1]   Titanium implants and lateral forces - An experimental study with sheep [J].
Asikainen, P ;
Klemetti, E ;
Vuillemin, T ;
Sutter, F ;
Rainio, V ;
Kotilainen, R .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (06) :465-468
[2]   Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat [J].
Branemark, R ;
Ohrnell, LO ;
Nilsson, P ;
Thomsen, P .
BIOMATERIALS, 1997, 18 (14) :969-978
[3]   Load-related implant reaction of mini-implants used for orthodontic anchorage [J].
Büchter, A ;
Wiechmann, D ;
Koerdt, S ;
Wiesmann, HP ;
Piffko, J ;
Meyer, U .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) :473-479
[4]   The use of microimplants in orthodontic anchorage [J].
Chen, Chung-Ho ;
Chang, Chao-San ;
Hsieh, Chi-Hsin ;
Tseng, Yu-Chuan ;
Shen, Yee-Shyong ;
Huang, I-Yueh ;
Yang, Chia-Fu ;
Chen, Chun-Ming .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (08) :1209-1213
[5]  
Chen YJ, 2006, INT J ORAL MAX IMPL, V21, P283
[6]  
Cheng SJ, 2004, INT J ORAL MAX IMPL, V19, P100
[7]  
De Pauw GAM, 1999, ANGLE ORTHOD, V69, P401
[8]   Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws [J].
Heidemann, W ;
Gerlach, KL ;
Grobel, KH ;
Kollner, HG .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (01) :50-55
[9]  
Ivanoff CJ, 1996, CLIN ORAL IMPLAN RES, V7, P120
[10]  
Kanomi R, 1997, J Clin Orthod, V31, P763