Electrochemical aptasensor for sensitive detection of Cardiac troponin I based on CuNWs/MoS2/rGO nanocomposite

被引:23
作者
Han, Yujie [1 ]
Su, Xujie [1 ]
Fan, Lifang [1 ]
Liu, Zhiguang [1 ]
Guo, Yujing [1 ]
机构
[1] Shanxi Univ, Inst Environm Sci, Taiyuan 030006, Peoples R China
基金
中国国家自然科学基金;
关键词
Cardiac troponin I; Electrochemical aptasensor; Copper nanowires; Molybdenum disulfide; Reduced graphene oxide; LABEL-FREE; APTAMER; BIOSENSORS; NANOSHEETS; DIAGNOSIS; BIOMARKER; PLATFORM;
D O I
10.1016/j.microc.2021.106598
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiac troponin I (cTnI) is a "gold standard biomarker" for clinical diagnose of acute myocardial infarction (AMI). Rapid, accurate, and sensitive detection methods for cTnI are highly urgent and significant in early diagnosis and progression control. In this work, we proposed an electrochemical aptasensing platform for cTnI detection based on copper nanowires/molybdenum disulfide/reduced graphene oxide (CuNWs/MoS2/rGO) ternary nanostructure. The CuNWs/MoS2/rGO composite exhibited improved electrochemical activity due to the high electrochemical conductivity and the synergistic effect among each component, and the large surface area, which also facilitates the immobilization of aptamers. As a result, the constructed electrochemical cTnI aptasensor shows good selectivity, stability, and reproducibility towards cTnI. Under optimized conditions, the aptasensor responses cTnI linearly from 5.0 x 10(-13) to 1.0 x 10(-10) g mL(-1) with a detection limit of 1.0 x 10(-13) g mL(-1) (S/N = 3). The analysis of cTnI in human blood samples demonstrated its practicability with comparable results. This work offers an alternative way for facile fabrication of CuNWs/MoS2/rGO based aptasensor for clinical biomarker detection.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A novel DNAzyme-driven walker-walkers serial amplified electrochemical aptasensor for ultrasensitive detection of cardiac troponin I
    Huang, Jiangjian
    Zhu, Tong
    Ruan, Jia
    Xu, Xiaohansi
    Su, Xin
    Ma, Yi
    Yang, Renxiang
    Li, Na
    Su, Huilan
    MICROCHEMICAL JOURNAL, 2023, 191
  • [42] Electro-immunosensor for ultra-sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine
    Brussasco, Jessica G.
    Guedes, Pedro H. G.
    Moco, Anna C. R.
    Moraes, Dayane D.
    Flauzino, Jose M. R.
    Silva, Heliane S.
    Silva, Atair C.
    Silva, Jonathan P.
    Madurro, Joao M.
    Brito-Madurro, Ana G.
    JOURNAL OF MOLECULAR RECOGNITION, 2023, 36 (02)
  • [43] An electrochemiluminescence aptasensor based on CdSe/ZnS functionalized MoS2 and enzymatic biocatalytic precipitation for sensitive detection of immunoglobulin E
    Liu, Yan-Ming
    Yang, Jiu-Jun
    Cao, Jun-Tao
    Zhang, Jing-Jing
    Chen, Yong-Hong
    Ren, Shu-Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 232 : 538 - 544
  • [44] Mechanochemical Preparation of a MoS2/Polyaniline Nanocomposite with High Electrochemical Capacity
    Kozarenko, O. A.
    Khazieieva, O. A.
    Dyadyun, V. S.
    Posudievsky, O. Yu.
    Koshechko, V. G.
    Pokhodenko, V. D.
    THEORETICAL AND EXPERIMENTAL CHEMISTRY, 2015, 51 (05) : 293 - 300
  • [45] Deoxynivalenol fluorescence aptasensor based on AuCu bimetallic nanoclusters and MoS2
    Duan, Nuo
    Li, Changxin
    Song, Mingqian
    Ren, Kexin
    Wang, Zhouping
    Wu, Shijia
    MICROCHIMICA ACTA, 2022, 189 (08)
  • [46] Electrochemical Sandwich-Type Aptasensor Based on the Multifunctional Catechol-Loaded Au/MIL-53(Fe) for Detection of Cardiac Troponin I
    Momeni, Fatemeh
    Khoshfetrat, Seyyed Mehdi
    Zarei, Kobra
    ACS APPLIED NANO MATERIALS, 2023, 6 (20) : 19239 - 19248
  • [47] An electrochemical aptasensor based on a TiO2/three-dimensional reduced graphene oxide/PPy nanocomposite for the sensitive detection of lysozyme
    Wang, Minghua
    Zhai, Shuyong
    Ye, Zihan
    He, Linghao
    Peng, Donglai
    Feng, Xiaozhong
    Yang, Yanqin
    Fang, Shaoming
    Zhang, Hongzhong
    Zhang, Zhihong
    DALTON TRANSACTIONS, 2015, 44 (14) : 6473 - 6479
  • [48] An electrochemical aptasensor for the highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on the hybridization chain reaction
    Jia, Li-Ping
    Wang, Li-Juan
    Ma, Rong-Na
    Shang, Lei
    Zhang, Wei
    Xue, Qing-Wang
    Wang, Huai-Sheng
    TALANTA, 2018, 179 : 414 - 419
  • [49] A Simple, sensitive, and selective electrochemical aptasensor for cortisol based on rGO-AuNPs
    da Silva, Alexsandra D.
    Paschoalino, Waldemir J.
    Kubota, Lauro T.
    ELECTROANALYSIS, 2023, 35 (05)
  • [50] Template Free Anisotropically Grown Gold Nanocluster Based Electrochemical Immunosensor for Ultralow Detection of Cardiac Troponin I
    Nisar, Sumaya
    Chansi, Ashish
    Mathur, Ashish
    Basu, Tinku
    Singh, Kshitij R. B.
    Singh, Jay
    BIOSENSORS-BASEL, 2022, 12 (12):