Geometrical and electrophysiological data of the moving membrane method for the osmotic water permeability of a lipid bilayer

被引:0
|
作者
Yano, Keita [1 ]
Iwamoto, Masayuki [1 ,2 ]
Koshiji, Takaaki [3 ]
Oiki, Shigetoshi [1 ,4 ]
机构
[1] Univ Fukui, Fac Med Sci, Dept Mol Physiol & Biophys, Fukui 9101193, Japan
[2] Univ Fukui, Fac Med Sci, Dept Surg, Fukui 9101193, Japan
[3] Univ Fukui, Fac Med Sci, Dept Mol Neurosci, Fukui 9101193, Japan
[4] Univ Fukui, Biomed Imaging Res Ctr, Fukui 9101193, Japan
来源
DATA IN BRIEF | 2021年 / 38卷
关键词
Water permeability; Bilayer tension; Unstirred layer; Lipid bilayer; Ion channel; Streaming potential; Gramicidin channel; STREAMING POTENTIALS; GRAMICIDIN CHANNELS; POTASSIUM CHANNEL; ION; MOLECULES;
D O I
10.1016/j.dib.2021.107309
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Data of the osmotic water permeability of a lipid bilayer (diphytanoylphosphaticylcholin) in the presence of cholesterol (30 mole%) are shown under the simultaneous measurement of bilayer tension. Detailed methods and procedures for evaluating the water permeability using the moving membrane method (K. Yano, M. Iwamoto, T. Koshiji & S. Oiki: Visualizing the Osmotic Water Permeability of a Lipid Bilayer under Measured Bilayer Tension Using a Moving Membrane Method. Journal of Membrane Science, 627 (2021) 119231) are presented. The planar lipid bilayer is formed in a glass capillary, separating two aqueous compartments with different osmolarities, and osmotically-driven water flux is visualized as membrane movements along the capillary. The water permeability was evaluated under constant membrane area and tension after correcting for the unstirred layer effect. In these measurements, geometrical features, such as the edge of the planar lipid bilayer and the contact angle between bilayer and monolayer, were image-analyzed. The unstirred layer was evaluated electrophysiologically, in which gramicidin A channel was employed. In the presence of an osmotic gradient, the gramicidin channel generates the stream-ing potential , the measured streaming potential data , the derived water-ion coupling ratio (water flux/ion flux) are shown. Detailed descriptions of the integrated method of the moving membrane allow researchers to reproduce the exper-iment and give opportunities to examine water permeability of various types of membranes, including those containing aquaporins. The present data of osmotic water permeability are compared with the previously published data, while they neglected the bilayer tension. (C) 2021 The Author(s). Published by Elsevier Inc.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] DIRECT EFFECT OF VASOPRESSIN ON WATER PERMEABILITY OF BILAYER LIPID-MEMBRANES
    LIVNE, A
    GRAZIANI, Y
    ISRAEL JOURNAL OF CHEMISTRY, 1971, 9 (06) : BC26 - &
  • [32] Distribution of ion pairs into a bilayer lipid membrane and its effect on the ionic permeability
    Omatsu, Terumasa
    Hori, Kisho
    Ishida, Naoto
    Maeda, Kohji
    Yoshida, Yumi
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2021, 1863 (11):
  • [33] Lipid Bilayer Interactions of Peptidic Supramolecular Polymers and Their Impact on Membrane Permeability and Stability
    Pannwitt, Stefanie
    Kaltbeitzel, Jonas
    Ahlers, Patrick
    Spitzer, Daniel
    Hellmann, Nadja
    Depoix, Frank
    Besenius, Pol
    Schneider, Dirk
    BIOCHEMISTRY, 2020, 59 (19) : 1845 - 1853
  • [34] Electrophysiological Analysis of Membrane Disruption by Bombinin and Its Isomer Using the Lipid Bilayer System
    Sekiya, Yusuke
    Shimizu, Keisuke
    Kitahashi, Yuki
    Ohyama, Akifumi
    Kawamura, Izuru
    Kawano, Ryuji
    ACS APPLIED BIO MATERIALS, 2019, 2 (04) : 1542 - 1548
  • [35] Structural determinants of water permeability through the lipid membrane
    Mathai, John C.
    Tristram-Nagle, Stephanie
    Nagle, John F.
    Zeidel, Mark L.
    JOURNAL OF GENERAL PHYSIOLOGY, 2008, 131 (01): : 69 - 76
  • [36] Effects of the Lipid Bilayer Phase State on the Water Membrane Interface
    Stepniewski, Michal
    Bunker, Alex
    Pasenkiewicz-Gierula, Marta
    Karttunen, Mikko
    Rog, Tomasz
    JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (36): : 11784 - 11792
  • [37] Dipeptides Embedded in a Lipid Bilayer Membrane as Synthetic Water Channels
    Kong, Xian
    Zhao, Zeyu
    Jiang, Jianwen
    LANGMUIR, 2017, 33 (42) : 11490 - 11495
  • [38] Droplet Interface Bilayer as Cell Membrane Mimics: Water Permeability Studies
    Lee, Sunghee
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 414A - 414A
  • [39] Measurement of water permeability: Droplet interface bilayer as a model for cell membrane
    Morales, Michael
    Bishop, Abigail
    Lee, Sunghee
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [40] Ibuprofen and the Phosphatidylcholine Bilayer: Membrane Water Permeability in the Presence and Absence of Cholesterol
    Wood, Megan
    Morales, Michael
    Miller, Elizabeth
    Braziel, Samuel
    Giancaspro, Joseph
    Scollan, Patrick
    Rosario, Juan
    Gayapa, Alyssa
    Krmic, Michael
    Lee, Sunghee
    LANGMUIR, 2021, 37 (15) : 4468 - 4480