Synthesis of NiO-CNTs nanocomposite for modification of glassy carbon electrode and Application for Electrochemical determination of fentanyl as an opioid analgesic drug

被引:15
作者
Ding, Hao [1 ]
Tao, Wei [1 ]
机构
[1] Wenhua Coll, Fdn Course Dept, Wuhan 430074, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2021年 / 16卷 / 11期
关键词
NiO@CNTs nanocomposite; Fentanyl; Clinical Samples; Differential pulse voltammetry; Selectivity; NANOTUBES; SUPERCAPACITOR; NANOPARTICLES; RECEPTOR; SENSOR; OXIDE;
D O I
10.20964/2021.11.33
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This study was focused on the synthesis of nanocomposite based on NiO and CNTs (NiO@CNTs) for modification of glassy carbon electrode (GCE) and application for electrochemical determination of fentanyl as an opioid analgesic drug. The NiO@CNTs nanocomposite was electrodeposited on the GCE surface. Results of structural analyses using SEM and XRD showed that the surface of the 3D of CNTs network was homogeneously covered by NiO nanoparticles, and the simultaneous electrodeposition of NiO nanoparticles and functionalized CNTs on GCE had been created a core-shell structure of NiO and CNTs with large void space between neighboring nanostructures. The results of electrochemical studies using CV and DPV techniques exhibited that the good conductivity of NiO and CNTs can contribute to the enhancement of the electrochemical response of the electrode toward fentanyl. The NiO@CNTs/GCE showed the selective and stable to determination fentanyl, and sensitivity, the limit of detection and linear range of NiO@CNTs/GCE as fentanyl sensor were obtained 1.12219 mu A/mu M, 0.01 mu M and 10 to 160 mu M respectively. Moreover, a comparison between the obtained sensing results of NiO@CNTs/GCE with reported fentanyl electrochemical sensor demonstrated comparable or better sensing properties and a wider linear range of NiO@CNTs/GCE than other reported electrochemical sensors. The results of the study indicated that the performance and precision of prepared electrodes for the analysis of fentanyl pharmaceutical and human serum samples showed acceptable precisions with appropriate recovery and RSD values. Therefore, of NiO@CNTs/GCE can be applied to accurate and reliable determination of fentanyl in clinical analyses.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条