Synthesis of NiO-CNTs nanocomposite for modification of glassy carbon electrode and Application for Electrochemical determination of fentanyl as an opioid analgesic drug

被引:15
作者
Ding, Hao [1 ]
Tao, Wei [1 ]
机构
[1] Wenhua Coll, Fdn Course Dept, Wuhan 430074, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2021年 / 16卷 / 11期
关键词
NiO@CNTs nanocomposite; Fentanyl; Clinical Samples; Differential pulse voltammetry; Selectivity; NANOTUBES; SUPERCAPACITOR; NANOPARTICLES; RECEPTOR; SENSOR; OXIDE;
D O I
10.20964/2021.11.33
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This study was focused on the synthesis of nanocomposite based on NiO and CNTs (NiO@CNTs) for modification of glassy carbon electrode (GCE) and application for electrochemical determination of fentanyl as an opioid analgesic drug. The NiO@CNTs nanocomposite was electrodeposited on the GCE surface. Results of structural analyses using SEM and XRD showed that the surface of the 3D of CNTs network was homogeneously covered by NiO nanoparticles, and the simultaneous electrodeposition of NiO nanoparticles and functionalized CNTs on GCE had been created a core-shell structure of NiO and CNTs with large void space between neighboring nanostructures. The results of electrochemical studies using CV and DPV techniques exhibited that the good conductivity of NiO and CNTs can contribute to the enhancement of the electrochemical response of the electrode toward fentanyl. The NiO@CNTs/GCE showed the selective and stable to determination fentanyl, and sensitivity, the limit of detection and linear range of NiO@CNTs/GCE as fentanyl sensor were obtained 1.12219 mu A/mu M, 0.01 mu M and 10 to 160 mu M respectively. Moreover, a comparison between the obtained sensing results of NiO@CNTs/GCE with reported fentanyl electrochemical sensor demonstrated comparable or better sensing properties and a wider linear range of NiO@CNTs/GCE than other reported electrochemical sensors. The results of the study indicated that the performance and precision of prepared electrodes for the analysis of fentanyl pharmaceutical and human serum samples showed acceptable precisions with appropriate recovery and RSD values. Therefore, of NiO@CNTs/GCE can be applied to accurate and reliable determination of fentanyl in clinical analyses.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] A glassy carbon electrode modified with carbon nanoonions for electrochemical determination of fentanyl
    Sohouli, Esmail
    Keihan, Amir Homayoun
    Shahdost-fard, Faezeh
    Naghian, Ebrahim
    Plonska-Brzezinska, Marta E.
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [2] Synthesis and Application of r-rhuEPO/NiO/CNTs modified Glassy Carbon Electrode as Sensor for Determination of Erythropoietin in the Blood of Athlete
    Duan, Furong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (12):
  • [3] Application of carbon nanoonion-NiMoO4-MnWO4 nanocomposite for modification of glassy carbon electrode: Electrochemical determination of ascorbic acid
    Mohammadnia, Maryam Saleh
    Khosrowshahi, Elnaz Marzi
    Naghian, Ebrahim
    Keihan, Amir Homayoun
    Sohouli, Esmail
    Plonska-Brzezinska, Marta E.
    Sobhani-Nasab, Ali
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MICROCHEMICAL JOURNAL, 2020, 159
  • [4] Electrochemical determination of dopamine using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous platinum-yttrium and graphene
    Chen, Dandan
    Tian, Chunhuan
    Li, Xiangyi
    Li, Zihan
    Han, Zhida
    Zhai, Chun
    Quan, Ying
    Cui, Rongjing
    Zhang, Genhua
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [5] Electrochemical Sensors for Detection of Phenol in Oilfield Wastewater Using TiO2/CNTs nanocomposite Modified Glassy Carbon Electrode
    Zheng, Wei
    Zhou, ZhiGuo
    Wang, Lan
    Gao, Yang
    Chen, ShiJun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (11):
  • [6] Electrochemical sensing of fentanyl as an anesthesia drug on NiO nanodisks combined with the carbon nanotube-modified electrode
    Li, Xi
    Luo, Bo
    Liao, Min
    Mohamed, Abdullah
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [7] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [8] Electrochemical Determination Venlafaxine at NiO/GR Nanocomposite Modified Carbon Paste Electrode
    Boroujeni, Aramesh Zahra
    Aghbalaghi, Zahra Asadi
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2021, 40 (04): : 1042 - 1053
  • [9] NiO/CNTs Nanocomposite Modified Ionic Liquid Carbon Paste Electrode as a Voltammetric Sensor for Determination of Quercetin
    Gupta, Vinod Kumar
    Golestani, Fereshteh
    Ahmadzadeh, Saeid
    Karimi-Maleh, Hassan
    Fazli, Gozal
    Khosravi, Sahebe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (04): : 3657 - 3667
  • [10] Application of Chitosan and the Green Synthesized NiO-Bi2O3 Nanocomposite in Modification of Glassy Carbon Electrode for Simultaneous Determination of p-Nitrophenol and o-Nitrophenol
    Hasan, Ibrahem M. A.
    Abd-Elsabour, Mohamed
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)