Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron

被引:325
作者
Liu, B. [1 ,2 ]
Zheng, Y. F. [1 ,2 ,3 ]
机构
[1] Peking Univ, Coll Engn, State Key Lab Turbulence & Complex Syst, Beijing 100871, Peoples R China
[2] Peking Univ, Coll Engn, Dept Adv Mat & Nanotechnol, Beijing 100871, Peoples R China
[3] Peking Univ, Acad Adv Interdisciplinary Studies, Ctr Biomed Mat & Tissue Engn, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
Iron; Biodegradable metal; Corrosion; Cytotoxicity; Hemocompatibility; DEGRADATION KINETICS; GRAIN-BOUNDARIES; TIN SEGREGATION; CORROSION; STENTS; CYTOTOXICITY; MECHANISM; MAGNESIUM; METAL; STEEL;
D O I
10.1016/j.actbio.2010.11.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pure iron was determined to be a valid candidate material for biodegradable metallic stents in recent animal tests; however, a much faster degradation rate in physiological environments was desired. C. Mn, Si, P. S. B, Cr, Ni, Pb, Mo, Al, Ti, Cu, Co, V and W are common alloying elements in industrial steels, with Cr, Ni, Mo, Cu, Ti, V and Si being acknowledged as beneficial in enhancing the corrosion resistance of iron. The purpose of the present work (using Fe-X binary alloy models) is to explore the effect of the remaining alloying elements (Mn, Co, Al, W, B, C and S) and one detrimental impurity element Sn on the biodegradability and biocompatibility of pure iron by scanning electron microscopy, X-ray diffraction, metallographic observation, tensile testing, microhardness testing, electrochemical testing, static (for 6 months) and dynamic (for 1 month with various dissolved oxygen concentrations) immersion testing, cytotoxicity testing, hemolysis and platelet adhesion testing. The results showed that the addition of all alloying elements except for Sn improved the mechanical properties of iron after rolling. Localized corrosion of Fe-X binary alloys was observed in both static and dynamic immersion tests. Except for the Fe-Mn alloy, which showed a significant decrease in corrosion rate, the other Fe-X binary alloy corrosion rates were close to that of pure iron. It was found that compared with pure iron all Fe-X binary alloys decreased the viability of the L929 cell line, none of experimental alloying elements significantly reduced the viability of vascular smooth muscle cells and all the elements except for Mn increased the viability of the ECV304 cell line. The hemolysis percentage of all Fe-X binary alloy models were less than 5%, and no sign of thrombogenicity was observed. In vitro corrosion and the biological behavior of these Fe-X binary alloys are discussed and a corresponding mechanism of corrosion of Fe-X binary alloys in Hank's solution proposed. As a concluding remark, Co, W, C and S are recommended as alloying elements for biodegradable iron-based biomaterials. (C) 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1407 / 1420
页数:14
相关论文
共 47 条
[1]   THE MECHANISM OF PITTING OF HIGH-PURITY IRON IN NACL SOLUTIONS [J].
ALVAREZ, MG ;
GALVELE, JR .
CORROSION SCIENCE, 1984, 24 (01) :27-&
[2]  
[Anonymous], ACTA MAT
[3]  
[Anonymous], 1999, ANN BOOK ASTM STAND, V03.01
[4]  
[Anonymous], 1990, ASTM G 31-72.
[5]   Biocompatibility and hemocompatibility of surface-modified NiTi alloys [J].
Armitage, DA ;
Parker, TL ;
Grant, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :129-137
[6]  
Bringas J.E., 2004, Handbook of comparative world steel standards
[7]   Effect of surface chemistries and characteristics of Ti6Al4V on the Ca and P adsorption and ion dissolution in Hank's ethylene diamine tetra-acetic acid solution [J].
Chang, E ;
Lee, TM .
BIOMATERIALS, 2002, 23 (14) :2917-2925
[8]  
Crichton R., 2001, Inorganic Biochemistry of Iron Metabolism: From Molecular Mechanisms to Clinical Consequences, V2nd
[9]   In-vivo measurements of wall shear stress in human coronary arteries [J].
Doriot, PA ;
Dorsaz, PA ;
Dorsaz, L ;
De Benedetti, E ;
Chatelain, P ;
Delafontaine, P .
CORONARY ARTERY DISEASE, 2000, 11 (06) :495-502
[10]   The road to bioabsorbable stents: Reaching clinical reality? [J].
Erne, P ;
Schier, M ;
Resink, TJ .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (01) :11-16