Polymerization Shrinkage and Depth of Cure of Bulk-Fill Resin Composites and Highly Filled Flowable Resin

被引:139
作者
Jang, J-H [1 ]
Park, S-H [2 ]
Hwang, I-N [3 ]
机构
[1] Kyung Hee Univ Hosp Gangdong, Dept Conservat Dent, Seoul, South Korea
[2] Yonsei Univ, Oral Sci Res Ctr, Conservat Dent, Seoul 120749, South Korea
[3] Chonnam Natl Univ, Coll Dent, Dept Conservat Dent, Gwang Ju, South Korea
关键词
MECHANICAL-PROPERTIES; STRESS; MICROHARDNESS;
D O I
10.2341/13-307-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the polymerization behavior and depth of cure (DOC) of recently introduced resin composites for posterior use: highly filled flowable composite and composites for bulk fill. A highly filled flowable (G-aenial Universal Flo [GUF]), two bulk-fill flowables (Surefil SDR Flow [SDR] and Venus Bulk fill [VBF]), and a bulk-fill nonflowable composite (Tetric N-Ceram Bulk fill [TBF]) were compared with two conventional composites (Tetric Flow [TF], Filtek Supreme Ultra [FS]). Linear polymerization shrinkage and polymerization shrinkage stress were each measured with custom-made devices. To evaluate DOC, the composite specimen was prepared using a mold with a hole of 4 mm depth and 4 mm internal diameter. The hole was bulk filled with each of the six composites and light cured for 20 seconds, followed by 24 hours of water storage. The surface hardness was measured on the top and the bottom using a Vickers microhardness (HV) indenter. The linear polymerization shrinkage of the composite specimens after photo-initiation decreased in the following order: TF and GUF. VBF. SDR. FS and TBF (p<0.05). The polymerization shrinkage stress of the six composite groups decreased in the following order: GUF > TF and VBF > SDR > FS and TBF (p<0.05). The mean bottom surface HV of SDR and VBF exceeded 80% of the top surface HV (HV-80%). However, the bottom of GUF and TBF failed to reach HV-80%. A highly filled flowable (GUF) revealed limitations in polymerization shrinkage and DOC. Bulk-fill flowables (SDR and VBF) were properly cured in 4-mm bulk, but they shrank more than the conventional nonflowable composite. A bulk-fill nonflowable (TBF) showed comparable shrinkage to the conventional nonflowable composite, but it was not sufficiently cured in the 4-mm bulk.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 38 条
[1]   Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments [J].
Abbas, G ;
Fleming, GJP ;
Harrington, E ;
Shortall, ACC ;
Burke, FJT .
JOURNAL OF DENTISTRY, 2003, 31 (06) :437-444
[2]   A characterization of first-generation flowable composites [J].
Bayne, SC ;
Thompson, JY ;
Swift, EJ ;
Stamatiades, P ;
Wilkerson, M .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1998, 129 (05) :567-577
[3]   Properties of Hybrid Resin Composite Systems Containing Prepolymerized Filler Particles [J].
Blackham, J. T. ;
Vandewalle, K. S. ;
Lien, W. .
OPERATIVE DENTISTRY, 2009, 34 (06) :697-702
[4]  
Bouschlicher MR, 2004, OPER DENT, V29, P698
[5]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[6]   In vitro comparison of mechanical properties and degree of cure of bulk fill composites [J].
Czasch, Pascal ;
Ilie, Nicoleta .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) :227-235
[7]   Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives [J].
Davidson, CL ;
Feilzer, AJ .
JOURNAL OF DENTISTRY, 1997, 25 (06) :435-440
[8]   An alternative method to reduce polymerization shrinkage in direct posterior composite restorations [J].
Deliperi, S ;
Bardwell, DN .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (10) :1387-1398
[9]  
Eick J D, 1986, Quintessence Int, V17, P103
[10]   Creep deformation of restorative resin-composites intended for bulk-fill placement [J].
El-Safty, S. ;
Silikas, N. ;
Watts, D. C. .
DENTAL MATERIALS, 2012, 28 (08) :928-935