Foot forces during exercise on the International Space Station

被引:48
作者
Genc, K. O. [1 ,2 ]
Gopalakrishnan, R. [3 ]
Kuklis, M. M. [3 ]
Maender, C. C. [4 ]
Rice, A. J. [3 ]
Bowersox, K. D. [5 ]
Cavanagh, P. R. [1 ]
机构
[1] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44106 USA
[4] NASA, Lyndon B Johnson Space Ctr, Houston, TX 77058 USA
[5] Increment 6 Astronaut, Houston, TX USA
关键词
Bone loss; Microgravity; Locomotion; Resistance exercise; Ergometer; Countermeasures; Spaceflight; Mechanical loading; LONG-DURATION SPACEFLIGHT; RESISTIVE EXERCISE; BONE; GRAVITY; COUNTERMEASURES; STRENGTH; IMPACT; FLIGHT; MUSCLE;
D O I
10.1016/j.jbiomech.2010.06.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Long-duration exposure to microgravity has been shown to have detrimental effects on the human musculoskeletal system. To date, exercise countermeasures have been the primary approach to maintain bone and muscle mass and they have not been successful. Up until 2008, the three exercise countermeasure devices available on the International Space Station (ISS) were the treadmill with vibration isolation and stabilization (TVIS), the cycle ergometer with vibration isolation and stabilization (CEVIS), and the interim resistance exercise device (iRED). This article examines the available envelope of mechanical loads to the lower extremity that these exercise devices can generate based on direct in-shoe force measurements performed on the ISS. Four male crewmembers who flew on long-duration ISS missions participated in this study. In-shoe forces were recorded during activities designed to elicit maximum loads from the various exercise devices. Data from typical exercise sessions on Earth and on-orbit were also available for comparison. Maximum on-orbit single-leg loads from TVIS were 1.77 body weight (BW) while running at 8 mph. The largest single-leg forces during resistance exercise were 0.72 BW during single-leg heel raises and 0.68 BW during double-leg squats. Forces during CEVIS exercise were small, approaching only 0.19 BW at 210W and 95 RPM. We conclude that the three exercise devices studied were not able to elicit loads comparable to exercise on Earth, with the exception of CEVIS at its maximal setting. The decrements were, on average, 77% for walking, 75% for running, and 65% for squats when each device was at its maximum setting. Future developments must include an improved harness to apply higher gravity replacement loads during locomotor exercise and the provision of greater resistance exercise capability. The present data set provides a benchmark that will enable future researchers to judge whether or not the new generation of exercise countermeasures recently added to the ISS will address the need for greater loading. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3020 / 3027
页数:8
相关论文
共 24 条
  • [1] Foot forces during typical days on the international space station
    Cavanagh, P. R.
    Genc, K. O.
    Gopalakrishnan, R.
    Kuklis, M. M.
    Maender, C. C.
    Rice, A. J.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (11) : 2182 - 2188
  • [2] An Ambulatory Biomechanical Data Collection System for Use in Space: Design and Validation
    Cavanagh, Peter R.
    Gopalakrishnan, Raghavan
    Rice, Andrea J.
    Genc, Kerim O.
    Maender, Christian C.
    Nystrom, Peter G.
    Johnson, Micah J.
    Kuklis, Matthew M.
    Humphreys, Bradley T.
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2009, 80 (10): : 870 - 881
  • [3] Applied horizontal force increases impact loading in reduced-gravity running
    Chang, YH
    Hamerski, CM
    Kram, R
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (05) : 679 - 685
  • [4] Planning strategies for development of effective exercise and nutrition countermeasures for long-duration space flight
    Convertino, VA
    [J]. NUTRITION, 2002, 18 (10) : 880 - 888
  • [5] EXERCISE COUNTERMEASURES FOR SPACEFLIGHT
    CONVERTINO, VA
    SANDLER, H
    [J]. ACTA ASTRONAUTICA, 1995, 35 (4-5) : 253 - 270
  • [6] Genc KO, 2006, AVIAT SPACE ENVIR MD, V77, P1117
  • [7] Enhanced Daily Load Stimulus to Bone in Spaceflight and on Earth
    Genc, Kerim O.
    Humphreys, Brad T.
    Cavanagh, Peter R.
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2009, 80 (11): : 919 - 926
  • [8] Muscle Volume, Strength, Endurance, and Exercise Loads During 6-Month Missions in Space
    Gopalakrishnan, Raghavan
    Genc, Kerim O.
    Rice, Andrea J.
    Lee, Stuart M. C.
    Evans, Harlan J.
    Maender, Christian C.
    Ilaslan, Hakan
    Cavanagh, Peter R.
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2010, 81 (02): : 91 - 102
  • [9] Perspective on the impact of weightlessness on calcium and bone metabolism
    Holick, MF
    [J]. BONE, 1998, 22 (05) : 105S - 111S
  • [10] Reduction in proximal femoral strength due to long-duration spaceflight
    Keyak, J. H.
    Koyama, A. K.
    LeBlanc, A.
    Lu, Y.
    Lang, T. F.
    [J]. BONE, 2009, 44 (03) : 449 - 453