Determination of solanesol by coulometric titration

被引:1
|
作者
Liu, KZ [1 ]
Liu, M
Li, DL
机构
[1] Henan Univ, Dept Chem, Kaifeng 475001, Peoples R China
[2] Shoudu Med Univ, Beijing 100875, Peoples R China
关键词
coulometric titration; solanesol; determination;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for determination of solanesol by coulometric titration was developed. The titration was carried out in a mixture of 2M KBr-glacial acetic acid (22:78 v/v), and bromine was generated at the anode. Solanesol reacted with bromine with a value of n = 18. The end point of the titration was detected with two-electrode amperometry. The method is rapid, accurate and can be used to determine small amount of sample.
引用
收藏
页码:1947 / 1954
页数:8
相关论文
共 50 条
  • [21] Coulometric titration at low temperatures - nonstoichiometric silver selenide
    Beck, G
    Janek, J
    SOLID STATE IONICS, 2004, 170 (1-2) : 129 - 133
  • [22] A STUDY OF THE CATHODE REACTION IN KARL FISCHER COULOMETRIC TITRATION
    KATOH, H
    FUJIMOTO, Y
    KUWATA, S
    ANALYTICAL SCIENCES, 1991, 7 (02) : 299 - 302
  • [23] Karl Fischer coulometric titration using a diaphragmless cell
    Katoh, H
    Katayama, N
    Kaneko, T
    BUNSEKI KAGAKU, 1999, 48 (07) : 711 - 715
  • [24] An universal cell for external generation of agents in a coulometric titration
    Pawlowski, W
    Jedral, W
    Gierulska, D
    CHEMIA ANALITYCZNA, 1997, 42 (01): : 101 - 105
  • [25] COULOMETRIC TITRATION OF SODIUM OXALATE WITH ELECTROGENERATED LEAD(II)
    TANAKA, T
    TAKAHASHI, A
    KOBAYASHI, S
    MIZUIKE, A
    ANALYTICAL SCIENCES, 1993, 9 (04) : 455 - 457
  • [26] Determination of chromium(VI) and total chromium in water by in-electrode coulometric titration in a porous glassy carbon electrode
    Manova, Alena
    Humenikova, Sona
    Strelec, Milan
    Beinrohr, Ernest
    MICROCHIMICA ACTA, 2007, 159 (1-2) : 41 - 47
  • [27] Redox energetics of SrFeO3-δ -: a coulometric titration study
    Bakken, E
    Stolen, S
    Norby, T
    Glenne, R
    Budd, M
    SOLID STATE IONICS, 2004, 167 (3-4) : 367 - 377
  • [28] Development of a dissolved carbon dioxide sensor based on a coulometric titration
    Wiegran, K
    Trapp, T
    Cammann, K
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) : 120 - 124
  • [29] PRECISE COULOMETRIC TITRATION OF ANTIMONY(III) IN A HIGHLY ACIDIC SOLUTION
    HIOKI, A
    KUBOTA, M
    KAWASE, A
    ANALYST, 1992, 117 (06) : 997 - 1001
  • [30] Potentiometric and coulometric titration of 6-propyl-2-thiouracil
    Ciesielski, W
    Zakrzewski, R
    ANALYST, 1997, 122 (05) : 491 - 494