Voltammetric detection of glutathione: an adsorptive stripping voltammetry approach

被引:45
作者
Areias, Madalena C. C. [1 ]
Shimizu, Kenichi [2 ]
Compton, Richard G. [2 ]
机构
[1] Univ Fed Pernambuco, Ctr Ciencias Exatas & Nat, Dept Quim Fundamental, Av Jornalista Anibal Fernandes S-N,Cidade Univ, BR-50740560 Recife, PE, Brazil
[2] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, S Parks Rd, Oxford OX1 3QZ, England
关键词
HUMAN PLASMA; REDUCED GLUTATHIONE; ELECTROCHEMICAL DETERMINATION; CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; OXIDIZED GLUTATHIONE; CARBON NANOTUBES; THIOLS; ELECTRODE; CYSTEINE;
D O I
10.1039/c6an00550k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive, and rapid detection of glutathione by cyclic voltammetry using a bare glassy carbon electrode is reported in which glutathione forms a 1 : 1 complex compound with copper(II) ions. This complex compound is adsorbed onto the electrode surface and undergoes electrochemical oxidation at a characteristic oxidation potential of ca. -0.20 V vs. the standard mercury/mercurous sulphate reference electrode, which is used to detect the glutathione concentration. The linear dynamic range is obtained for a glutathione concentration from 1 mu M to 12.5 mu M, and the sensitivity is found to be 0.1 +/- 0.002 mu A mu M-1. A low limit of detection (n = 3) of 0.14 mu M and a precision of 1.8% are achieved using a simple, unmodified electrode. The robustness of the present methodology is demonstrated by the successful quantitative analysis of glutathione in the presence of cysteine.
引用
收藏
页码:2904 / 2910
页数:7
相关论文
共 53 条
  • [1] Electroanalytical exploitation of nitroso phenyl modified carbon-thiol interactions: Application to the low voltage determination of thiols
    Abiman, Poobalasingam
    Wildgoose, Gregory G.
    Compton, Richard G.
    [J]. ELECTROANALYSIS, 2007, 19 (04) : 437 - 444
  • [2] Ahmed M., 2014, WORLD APPL SCI J, V29, P1357, DOI DOI 10.5829/idosi.wasj.2013.23.09.580
  • [3] Voltammetric Detection of Captopril Using Copper(II) and an Unmodified Glassy Carbon Electrode
    Areias, Madalena C. C.
    Shimizu, Kenichi
    Compton, Richard G.
    [J]. ELECTROANALYSIS, 2016, 28 (07) : 1524 - 1529
  • [4] Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ
    Calvo-Marzal, Percy
    Chumbimuni-Torres, Karin Y.
    Hoehr, Nelci Fenalti
    Kubota, Lauro T.
    [J]. CLINICA CHIMICA ACTA, 2006, 371 (1-2) : 152 - 158
  • [5] Electrochemical determination of reduced glutathione (GSH) by applying the powder microelectrode technique
    Chen, J
    He, ZY
    Liu, H
    Cha, CS
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 588 (02): : 324 - 330
  • [6] Compton RG, 2011, UNDERSTANDING VOLTAMMETRY, 2ND EDITION, P1
  • [7] REGULATION OF CELLULAR GLUTATHIONE
    DENEKE, SM
    FANBURG, BL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (04): : L163 - L173
  • [8] Devadas B, 2013, INT J ELECTROCHEM SC, V8, P5241
  • [9] Rational attachment of synthetic triptycene orthoquinone onto carbon nanotubes for electrocatalysis and sensitive detection of thiols
    Gong, KP
    Zhu, XZ
    Zhao, R
    Xiong, SX
    Mao, LQ
    Chen, CF
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (24) : 8158 - 8165
  • [10] Biologic and pharmacologic regulation of mammalian glutathione synthesis
    Griffith, OW
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 1999, 27 (9-10) : 922 - 935